9. Connect the hand-held nutrunner/tigh-
tening spindle:
10. Connect the power supply connection
cable. The user is responsible for com-
plying with the regulations for the power
supply connection.
11. Switch the Compact System on at the
power switch.
Variants with integrated computer
unit: Configuring the computer unit
The integrated computer unit already has an
activated pre-installed Windows 7 opera-
ting system.
After the CS351 Compact System has
been switched on, the integrated computer
unit is started automatically and Windows 7
is opened.
The computer unit can only be
commissioned/configured while a
hand-held nutrunner or tightening
spindle is connected.
To ensure that the controller of the Com-
pact System can communicate with the in-
tegrated computer unit, the following steps
must be carried out on commissioning:
• Configure the integrated computer unit in
slot B2 in the BS350 operating program
of the Compact System.
• Configure the connection to the Com-
pact System via the Windows Control
Panel of the computer unit.
For information about controlling the
BS350 operating program, refer to the on-
line help and to the system documentation
on the enclosed USB system stick.
Bosch Rexroth AG
In the BS350 operating program:
1. Connect the BS350 operating program
to the Compact System.
2. The BS350 displays an interface
module IMpc 3608861118 for the
computer unit in module slot B2..
Confirm the selection.
3. Assign an IP address (e. g.
192.168.1.7) and a subnet mask (e. g.
255.255.255.0) to the module.
The IP address may not be
within the same address range
as the X7E1 Ethernet interface
of the controller, i.e., the IP
address must be different from
each other at least in one of the
three front parts. You can as-
sign IP address 192.168.1.7
to the module if the IP address
of X7E1 is, e. g., 192.168.0.7
or 192.168.2.2.
4. After having set the computer card in
module slot B2 of the operating pro-
gram, send the data to the Compact
System and then manually trigger a re-
set of the Compact System controller
(push and hold the reset button on the
front panel for approx. 1 second).
Windows Control Panel of the compu-
ter unit:
An USB mouse, an USB keyboard and a
monitor must be connected to the computer
unit.
1. Select "Control Panel" from the Win-
dows start menu.
2. Select "View network status and tasks"
and click the "Change Adapter Set-
tings" function.
This displays the list of LAN connec-
tions.
89/108
Commissioning