Table of Contents Introduction 2. Warranty information Complying with standards 4. Contents in the packing box 5. Information about your pump 6. Schematic drawings Key product specifications & features 8. Cross-section view Pre-installation requirements 10. Installation procedures 11. Basic troubleshooting 12.
1. Introduction Thank you for choosing a quality product manufactured by Texmo Industries. We request you to read this manual thoroughly so as to ensure that the product you have purchased will be operated correctly. This manual is intended to provide you with information on your product and information on installation and operation.
5. Information about your pump The discharge of a pump depends on the static suction facilities and will give trouble-free performance lift. During summer, the static suction lift increases if properly installed and maintained. These are due to drop in water levels, and this results in reduced compact pumping systems with the pump and motor discharge.
6. Schematic drawing View of an Single Phase Openwell Submersible Monoblock is shown below in Fig. 1: Fig. 1 View of Single Phase Openwell Submersible Monoblock OMOW002A 2020.01...
7. Key specifications & features Standard Specifications of Single Phase Openwell Submersible are shown below in TABLE 1: SVSM: 1.0, 1.5 HP Power SSM: 1 - 5 HP TSSM: 0.5, 1.0 HP Phase Motor Type Squirrel-cage Induction Motor – Wet type Operating Voltage 180 - 240 V Frequency...
Page 8
The water-filled motor is provided with single-lip oilseals to prevent the pumped medium from entering the motor To prevent sand / small stones from entering the seal chamber, a sand guard is provided The TSSM and SSM series products have a single impeller rotating within a volute casing The SVSM series is a multi-stage pump with NORYL impellers rotating inside a NORYL diffuser housing The impeller of TSSM and SSM are dynamically balanced.
8. Cross-section view Cross-section view of TSSM Series Openwell Submersible Monoblock is shown below in Fig. 2: Fig. 2 Cross-section view of single phase openwell submersible monoblock “TSSM” series 31 30 11 12 PART NAME PART NAME PART NAME Stator Stack Flange Oval Csk Head Hex Socket Set Screw...
Page 10
Cross-section view of a SSM Series Single Phase Openwell Submersible Monoblock is shown below in Fig. 3: Fig. 3 Cross-section view of single phase openwell submersible monoblock “SSM” series 41 40 39 38 37 36 35 27 26 25 24 23 12 13 15 16 17 18 19 20...
Page 11
Cross-section view of a SVSM Series Single Phase Vertical Openwell Submersible Monoblock is shown below in Fig. 4: Fig. 4 Cross-section of a single phase vertical openwell submersible monoblock “SVSM” series PART NAME PART NAME PART NAME Hex Socket Head Cap Washer Intermediate Housing Screw...
9. Pre-installation requirements Arrangement for Installation Use the services of a professional and trained mechanic with experience in erecting Openwell submersible Ensure proper safety precautions during installation Use the eye bolts / lifting lugs for lifting / lowering the Single Phase Openwell submersible using appropriate equipment General Installation Precautions Open the packaging and note down the serial number and model for future reference...
Page 13
If you detect damage or discrepancy in the product, contact the dealer from whom the pump was purchased Note Do not use this pump for oil or toxic, acidic, corrosive, and flammable liquids. Pumping flammable liquids could cause explosion Warning Use the eye bolt for lifting/lowering the Single Phase Openwell submersible.
Page 14
Check the bottom of the well. In case there is mud accumulated at the well bottom, de-silt the well Note Periodically de-silt the bottom of the well so that the Openwell Submersibles rests on the rocky bottom Note Operation Precautions Switch OFF the power before working on electrical lines Warning Do not use this pump for pumping liquid exceeding 33...
10. Installation procedure Please follow the below procedure to install the Single Phase Openwell Submersible monoblock The supply voltage should be within the specified voltage range. Water temperature for operation of the pump should not exceed 33 Failure to observe the precautions given above could cause the pump to Caution malfunction and may lead to current leakage or electrical shock.
Page 16
Fig. 5 Single phase openwell submersible monoblock with flooded suction Prior to installation, unscrew the Brass Plugs 1 and 2, fitted on top of the motor as shown in Fig. 5 below, WELL and fill the motor with pure drinking water till water overflows from the other filling hole.
Page 17
SVSM – Horizontal Mounting: Motor and pump stand assembly – procedure Refer Fig. 7 and Fig. 8 for the assembling the motor stand and pump stand. Fig. 7 Assembly procedure – Motor stand Remove the screws in the clamps (a) and insert Motor Stand in the motor base flange (b) as shown in below pictures and tight the screws (c).
Page 18
Waterproofing the Submersible Motor Cable - Supply Cable Joint Hazardous voltage will cause death, serious injury, electrocution Disconnect all power before working on this equipment and that it cannot be accidentally switched ON. Danger Standard Single Phase Openwell Submersible are supplied with a 3-core PVC-insulated flat cable of length 3 meters.
Page 19
Procedure for joining and insulating the Proedure for joining and insulating the 3 core conductors cable joint for under-water cable Step 1: Soldering / knot the copper strands Step 6: Layer 1 - 1st layer of virgin rubber insulation Step 2: Layer 1 - 1st layer of virgin rubber insulation Step 7: Layer 2 - 1st layer of PVC insulation tape Step 3: Layer 2 - 1st layer of PVC insulation tape Step 8: Layer 3 - 2nd layer of PVC insulation tape...
Page 20
Cable Lead Wire Connection to Control Panel Cable Terminal Yellow Blue Cable Selection Refer TABLE 2 for the selection of cables from Control Panel to Submersible Motor: Submersible Cable Selection Chart (For 220 V, 50 Hz Ac power supply) Cable size in Sq.mm Motor Rating Current 10.0...
Page 21
Checking direction of rotation of Single Phase Openwell Submersible Monoblock Hazardous voltage will cause death, serious injury, electrocution. All electrical work must be performed by an authorised electrician, in compliance with local electrical equipment standards and internal Danger wiring codes. Connect the Single Phase Openwell Submersible to the control panel, power up the Openwell Submersible, and observe if the direction of rotation of the impeller matches the arrow mark on the volute casing / suction chamber...
Page 22
Electrical Wiring Work All electrical work must be performed by an authorised electrician in compliance with local electrical equipment standards and internal wiring codes. Improper wiring can lead to current leakage, electrical shock, or fire. Warning Earthing Fig. 10 Earth Connections – SSM and SVSM DIRECTION FILLING / DRAIN OF ROTATION...
Page 23
Connecting the Power Supply Observe relevant Electricity Board regulations while powering up the pumpset Caution Before inserting the power plug or connecting the wires to the terminal board, make sure the power supply is properly disconnected. Failure to do so may lead to electrical shock, short, or injury caused by the unintended starting of the pump Warning Do not use damaged cables, power plugs, or loose power outlets.
11. Basic troubleshooting To prevent serious accidents, disconnect the power supply before inspecting the pump. Warning Read this operation manual thoroughly before requesting repair. Contact the dealer from whom the pump was purchased. Servicing and troubleshooting must be handled by qualified persons with proper tools and equipment. Common faults, root causes for these, and suggested actions are provided in TABLE 2 below: Fault Possible Causes...
Page 25
Fault Possible causes Suggested actions Clean the pipe Discharge pipe internally coated with depositions Check the impellers and remove the foreign bodies Foreign bodies lodged in impellers Check and clean / replace the valves, if necessary The valve in the discharge pipe is Less discharge partly closed / blocked from pump...
Page 26
Conduct trial operation after maintenance Note Dispose replaced components with appropriate care so as to protect the environment Note Do not try to solve unspecified troubles of Single Phase OWS as it may lead to severe damage to the pump or injury to personnel. Contact the dealer from whom this pump was purchased Warning If the Single Phase Openwell Submersible runs with unusual noise, stop it...
12. Preventive maintenance checks Precautions to be taken Disconnect the power supply before starting maintenance or inspection of the pump to avoid electrical shock Warning If you find any damages or abnormalities, switch OFF the pump and report the problem to the dealer from whom the set was purchased Note NOTE: The manufacturer assumes no responsibility for damage or injury due to disassembly in the field.
Page 29
It is good practice to monitor the conditions and performance of the Single Phase Openwell Submersible. Diagnosis may be carried out by checking the following: Closing the delivery valve for a few seconds only and check the shut-off head generated by the pump.
13. Do’s and don’ts Do’s Don’ts Before installation, rotate the shaft to ensure that Do not use piping smaller than what is mentioned on pump is not jammed the nameplate Ensure proper earthing is provided Do not place the pump at the bottom of the well as it can sink in the mud at the well bottom.
14. Important safety instructions Only qualified personnel should be involved for inspection, maintenance, and repairs. The successful and safe operation of such a product depends on proper handling, installation, and maintenance. It is suggested that in case of non-functioning of the product, the customer is requested to contact the dealer through whom the purchase was made.
15. Storage & handling The Single Phase Openwell Submersibles are supplied from the factory in proper packing in which they should remain until they are to be installed The product should be stored in a closed, dry, and well-ventilated room Do not store the products under direct sunlight Handle the pumps with care and do not expose the product to unnecessary impact and shocks During unpacking and prior to installation, care must be taken while handling the pump to ensure...
Need help?
Do you have a question about the Taro Pumps TSSM Series and is the answer not in the manual?