Kenwood TK-2217 Service Manual page 51

Vhf fm transceiver
Hide thumbs Also See for TK-2217:
Table of Contents

Advertisement

TK-2217
Receiver Section
Item
Condition
1.BPF Wave
(1)Center frequency
Adjust
Spectrum analyzer setting analyzer
Center-f : 155MHz
Span : 100MHz
RBW : 30kHz
VBW : 30kHz
ATT
(2)High-edge frequency
Spectrum analyzer setting
Center-f : 174MHz
(3)Low-edge frequency
Spectrum analyzer setting
Center-f : 136MHz
2.Sensitivity
TEST CH: Low
check
[Wide]
SSG otuput:–117 dBm(0.3µV) AF VTVM
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–115 dBm(0.4µV)
SSG MOD:1.5kHz
3.SQL1
TEST CH: Center
(Threshold)
writing
[Wide]
SSG otuput:–123 dBm(0.16µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–122 dBm(0.18µV)
SSG MOD:1.5kHz
4.SQL9
TEST CH: Center
(Tight)
writing
[Wide]
SSG otuput:–117 dBm(0.3µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH:Center
SSG otuput:–116 dBm(0.35µV)
SSG MOD:1.5kHz
5.BATT
BATT terminal voltage:5.75V DVM
Detection
Writing
50
ADJUSTMENT /
Measurement
Test equipment
Spectrum
: 5dB
SSG
Center
DVM
High
Oscilloscope
Low
High
Low
High
调整
Adjustment
Terminal
Parts
ANT
Programming
BPF
Software:
KPG-100D
ANT
Programming
Software:
KPG-100D
ANT
BATT terminal
Specifications/
Remark
Method
Adjust the
REF -20.0 dBm
10 dB/
A_View Norm B_Blank Norm -32.43 dBm
MARKER
waveform as
155 MHz
shown to the
right.
CENTER 155 MHz
SPAN 100.0 MHz
RBW 30 kHz VBW 30 kHz SWP 230 ms
REF -20.0 dBm
10 dB/
A_View Norm B_Blank Norm -30.70 dBm
MARKER
174 MHz
CENTER 174 MHz
SPAN 100.0 MHz
RBW 30 kHz VBW 30 kHz SWP 230 ms
REF -20.0 dBm
10 dB/
A_View Norm B_Blank Norm -30.73 dBm
MARKER
136 MHz
CENTER 136 MHz
SPAN 100.0 MHz
RBW 30 kHz VBW 30 kHz SWP 230 ms
Check
12dB SINAD or more
Write
Squelch open
Write
BATT terminal
voltage:5.75V
MKR 155 MHz
ATT 5 dB
MKR 174 MHz
ATT 5 dB
MKR 136 MHz
ATT 5 dB