3
25 m
/h nominal flow rate, mounting length 300
mm, flanged DN 65, PN 25, control cable length
3 m, Pt500, Ø 6 mm, sensor length 100 mm,
cable length 5 m, return sensor, not integrated
in the flow measuring section, energy unit MWh
3
40 m
/h nominal flow rate, mounting length 300
mm, flanged DN 80, PN 25, control cable length
3 m, Pt500, Ø 6 mm, sensor length 150 mm,
cable length 5 m, return sensor, not integrated
in the flow measuring section, energy unit MWh
3
60 m
/h nominal flow rate, mounting length 360
mm, flanged DN 100, PN 25, control cable
length 3 m, Pt500, Ø 6 mm, sensor length 150
mm, cable length 5 m, return sensor, not inte-
grated in the flow measuring section, energy
unit MWh
3
0.6 m
/h nominal flow rate, mounting length
110 mm, connecting thread G ¾", PN 16, con-
trol cable length 1.5 m, Pt500, DS M10x1 mm,
sensor length 27.5 mm, cable length 1.5 m,
return sensor, integrated in the flow measuring
section, energy unit kWh
3
1.5 m
/h nominal flow rate, mounting length
110 mm, connecting thread G ¾", PN 16, con-
trol cable length 1.5 m, Pt500, DS M10x1 mm,
sensor length 27.5 mm, cable length 1.5 m,
return sensor, integrated in the flow measuring
section, energy unit kWh
3
2.5 m
/h nominal flow rate, mounting length
130 mm, connecting thread G 1", PN 16, con-
trol cable length 1.5 m, Pt500, DS M10x1 mm,
sensor length 27.5 mm, cable length 1.5 m,
return sensor, integrated in the flow measuring
section, energy unit kWh
3
3.5 m
/h nominal flow rate, mounting length
260 mm, connecting thread G 1¼", PN 16,
control cable length 1.5 m, Pt500, DS
M10x1 mm, sensor length 38 mm, cable length
1.5 m, return sensor, integrated in the flow
measuring section, energy unit kWh
3
6 m
/h nominal flow rate, mounting length 260
mm, connecting thread G 1¼", PN 16, control
cable length 1.5 m, Pt500, DS M10x1 mm, sen-
sor length 38 mm, cable length 1.5 m, return
sensor, integrated in the flow measuring sec-
tion, energy unit kWh
3
10 m
/h nominal flow rate, mounting length 300
mm, flanged DN 40, PN 25, control cable length
1.5 m, Pt500, Ø 6 mm, sensor length 100 mm,
cable length 5 m, return sensor, integrated in
the flow measuring section, energy unit kWh
Ultrasonic heat and cooling energy meters UH50..
S55561-F119
UH50-A70-00
S55561-F120
UH50-A74-00
S55561-F121
UH50-A83-00
S55561-F122
UH50-C05-00
S55561-F123
UH50-C21-00
S55561-F124
UH50-C36-00
S55561-F125
UH50-C45-00
S55561-F126
UH50-C50-00
S55561-F127
UH50-C61-00