Changed Points; Specifications - Mitsubishi Electric LGH-F300RVX-E Handbook

Lossnay energy recovery ventilator
Hide thumbs Also See for LGH-F300RVX-E:
Table of Contents

Advertisement

2. Changed points

New model
LGH-F300RVX-E
LGH-F470RVX-E
LGH-F600RVX-E
LGH-F1200RVX-E LGH-F1200RX

3. Specifications

Model name
Heat exchange system
Heat exchanger material
Cladding
Heat insulation material
Motor
Filter
Surrounding air condition
Suction air condition
Supply fan operation under
low outdoor temperature
Function
Electrical power supply
Insulation resistance
Dielectric strength
Running
Model name
current
LGH-F300RVX-E
LGH-F470RVX-E
LGH-F600RVX-E
LGH-F1200RVX-E
* The above values apply during energy recovery ventilation when the fan speed is set to Fan speed 4 at the
rating pressure loss and 230 V / 60 Hz.
* For the specifications at the other frequency or voltages, see the spec. sheets.
* The values given in the table for the noise level reflect the levels measured at a position 4.9 feet (1.5 m)
immediately below the unit in an anechoic chamber.
* Noise change or increase may occur because of the Bypass-Automatic function or Automatic fan speed
change by timer setting and/or other functions.
* Temperature Exchange efficiency (%) are average of summer and winter condition.
* Mitsubishi Electric measures products according to Japan Industrial Standard (JIS B 8628:2003), therefore
characteristic values are measured by chamber method.
* On-site commissioning measurements by pitot tube method could be as much 20% difference from JIS test
room conditions. If the measuring point is close to sources of turbulence like bends, contractions and damp-
ers, etc., it is difficult to measure air volume correctly. A straight duct length more than 10 D (D=duct diame-
ter) from the source of turbulence is recommended for correct measurement. On-site measurement should
therefore be measured in accordance with BSRIA guideline (Commissioning Air System. Application proce-
dures for buildings AG3/89.3 (2001))
Former model
LGH-F300RX
-E
5
LGH-F470RX
-E
5
LGH-F600RX
-E
5
-E
5
LGH-F300RVX-E, LGH-F470RVX-E, LGH-F600RVX-E, LGH-F1200RVX-E
Energy recovery ventilating system
Special treated paper plate heat exchanger
Galvanized steel sheet
Self-extinguishing urethane foam
EC motor
Non-woven fabrics filter (EU-G3)
Shall be between 14°F (-10°C) and 104°F (40°C), 80%RH or less
Shall be lower than 104°F (40°C), 80%RH
14°F (-10°C) to 5°F (-15°C) : Intermittent operation 60 min ON, 10 min OFF
5°F (-15°C) or less: Intermittent operation 55 min OFF, 5 min ON
Energy recovery ventilation/Bypass ventilation, Fan speed 1, 2, 3, 4
Single phase 208-230 V / 60 Hz
10 MΩ or more
1000 V AC 1 minute
Air volume
Input
power
(A)
(W)
(CFM) (CMH) (W/CFM) (in W.G)
1.06
155
300
510
2.15
348
470
799
2.70
438
600
1019
5.40
880
1200
2039
Changes from the former model
Circuit board: Newly designed
Motor: Changed from AC motor to DC motor
Operation in extremely cold regions: Unavailable
Static pressure
Exchange efficiency (%)
(Pa) Temperature
0.52
0.46
115
0.74
0.60
150
0.73
0.66
164
0.73
0.59
147
─ 4 ─
Noise
(dB)
Enthalpy
Below
the unit
Heating Cooling
65.5
63.0
50.0
34.0
69.0
64.0
51.0
34.5
67.0
64.0
50.0
37.0
67.0
64.0
50.0
41.0
Dia. of the
Weight
centrifugal
fan
(lbs) (kg)
(Inch (mm))
8 3/4 (220) 75
34
9 5/8 (245) 110
50
9 5/8 (245) 123
56
9 5/8 (245) 251 114