Chapter 6. Troubleshooting Table; Failure Diagnosis By Led In Front Of Cabinet; Led Flashing Specification At The Time Of An Error (Power And Timer Icon Led Used) - Sharp LC-60LE660U Service Manual

Lcd color television
Hide thumbs Also See for LC-60LE660U:
Table of Contents

Advertisement

CHAPTER 6.
LC-60LE660U
TROUBLESHOOTING TABLE

[1] Failure diagnosis by LED in front of cabinet

Is the Power and Timer Icon flashing?
Check " Picture does not display.".

[2] LED flashing specification at the time of an error (Power and Timer icon LED used)

1. Display method
Since Power and Timer icon LED can be used, slow flashing and fast flashing are combined.
After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the adjustment process mode.
2. LED flashing method
Error flashing
POWER indicator
TIMER indicator
Table 1. Concrete flashing pattern
Item
Inverter/Lamp system failure
Power PWB
failure
(Power failure, etc.)
Main PWB
failure
(Communication
failure, etc.)
Others
VerUP executing
VerUP succeeded
VerUP failed
ROM data failure
*1: When there is no SLEEP/OPC LED, use another LED.
*2: They depend on the system. Power supply error is defined from product to product.
*3: For details, refer to ERROR STANDBY CAUSE on the process screen.
*4: If the boot section is abnormal, there is no flashing (flashing impossible).
START
Yes
Check "[2] LED flashing specification at the time of an error (Power and Timer icon LED used)".
No
No
Is the Power Icon lighting
Check Power-Unit and AC-cable.
When AC plug on?
Yes
No
Is the Backlight lighting?
Check " LED Backlight does not turn on.".
Yes
Detail display
POWER indicator
Flashes once
Flashes twice
Flashes 3 times
Flashes 4 times
Green flashes continuously.
POWER (Green) and SLEEP/OPC(*1) flash alternately.
Green flashes fast.
Green flashes fast.
Service Manual
TIMER indicator (*1)
Flashes once
Lamp error
Flash once
Power supply error 1 (*2) AC_DET error
Flash twice
Power supply error 2 (*2) UR+13.5V error
Flash 3 times
Power supply error 3 (*2) D+3.3V error
Flash 5 times
Power supply error 5 (*2) Panel power supply
error
Flash 6 times
Power supply error 6 (*2) DRC power supply
error
Flash 7 times
Power supply error 7 (*2) FRC power supply
error
Flashes once
Initial communication error
Flashes twice
Start-up confirmation communication error
Flashes 3 times
Regular communication error
Flashes 5 times
Other communication error
Flashes once
Temperature error
Flash twice
Synchronism error
Flashes 3 times
Notification from the main microprocessor (*3)
OFF
Sub microcomputer version upgrading
Sub microcomputer version upgrade succeeded
OFF
Version upgrade failed
OFF
Start-up after failing version upgrade (*4)
6 – 1
LC-60/70LE660U,C6600U
Cause

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-60c6600uLc-70le660uLc-70c6600u