1-1. Operating Environment (Common)

Operation guaranteed temperature:
Performance guaranteed temperature: +10 dC to +35 dC
Operating humidity:
Storage temperature:
Mass
ICP-X7000 (4ME): Approx. 39.0 kg
ICP-X7000 (3ME): Approx. 30.0 kg
ICP-X7000 (2ME): Approx. 22.0 kg
MKS-X7075:
Approx. 2.0 kg
MKS-X7011:
Approx. 2.5 kg
MKS-X2700:
Approx. 8.0 kg
MKS-X7700:
Approx. 15.0 kg
Prohibited locations for installation
. Areas where the unit will be exposed do direct sunlight
or any other strong lights.
. Dusty areas
. Areas subject to vibration.
. Areas with strong electric or magnetic fields.
. Areas near heat sources.
. Areas where is subject to electrical noise.
. Areas subject to static electricity
Ventilation
The inside of the MKS-X2700/MKS-X7700 is cooled by a
fan (side on the rear).
The power supply can be damaged if the exhaust vent (side
on the rear) and air intake (front panel) are blocked or the
fan is stopped.
ICP-X7000
Section 1

Installation

1-2. Power Supply

+5 dC to +40 dC

1-2-1. Power Specifications

10 % to 90 %
1. MKS-X2700/MKS-X7700
_20 dC to +60 dC
Power requirements: AC 100V to 240 V ?10 %
Power frequency:
Current consumption:
MKS-X2700: Maximum 0.5 A
MKS-X7700: Maximum 1.0 A
n
As the inrush current flows at turn-on, the capacity of the
AC power source must be commensurate with this load.
If the capacity of the AC power is not adequately large, the
AC power source breaker will operate or the unit will
abnormally operate.
Inrush current:
MKS-X2700: Maximum 85 A (at peak)/20 A r.m.s (AC 240 V)
MKS-X7700: Maximum 90 A (at peak)/20 A r.m.s (AC 240 V)
2. ICP-X7000, MKS-X7075, MKS-X7011
ICP-X7000, MKS-X7075, and MKS-X7011 operate with
power supplied from the PoE HUB or the supplied AC
adaptor. Both of these power supplies can be operated as
redundant power supply.
With respect to the model name of recommended PoE
HUB, contact your local Sony Sales Office/Service Center.
AC adaptor power: AC100 V to 240 V 50/60Hz
Current consumption:
ICP-X7000 (per row): Maximum 0.3 A
MKS-X7075:
MKS-X7011:
Inrush current:
ICP-X7000 (per row): 70 A (at peak), 10 A r.m.s. (AC 240 V)
MKS-X7075:
MKS-X7011:
50/60 Hz
Maximum 0.2 A
Maximum 0.3 A
70 A (at peak), 10 A r.m.s. (AC 240 V)
70 A (at peak), 10 A r.m.s. (AC240 V)