6.3

Arguments Used by Functions

The following table lists the arguments used by the communication library functions.
All of the arguments of the communication library are specified using the same character string as used for the
communication settings of the MC protocol in ASCII code.
Argument
Data type
ClrMode
CmdData
CmdMode
CpuTime
CpuNo
DevCode
DevData
DevNo
DevNum
Character
HostName
string
NetNo
PassWord
PcNo
PortNo
ProxyName
RetType
54
Overview
Specifies the clear mode.
Specifies the application data (subheader + text (command)) of the
MC protocol (QnA compatible 3E frame).
Specifies the remote operation mode.
Specifies the CPU monitoring timer.
Specifies the target CPU (request destination module I/O No.)
Specifies the device code.
Specifies data for the number of device.
Specifies the head device number.
Specifies the number of device.
Specifies the IP address or host name of the connection target
Ethernet module.
Specifies the network No. to be routed thorough last.
Specifies the remote password.
Specifies the PC No. of the access station.
Specifies the HTTP port No.
Specifies the IP address or host name of the proxy server.
Specifies the execution result type.
1: Actual data only
Returns only the application data (subheader + text (response))
returned from the CPU module.
Other than 1: Normal execution result
Returns the data edited in the communication library.
Setting range
Reference
00, 01, and 02
Enter according to the
MC protocol format.
0001, 0003
0000 to FFFF
0000 to 01FF,
Refer to the
03E0 to 03E3, 03FF
reference manual.
( Page 55, Section
6.3 (1))
( Page 55, Section
6.3 (1))
1 to 960
Refer to the
00 to EF, and FE
reference manual.
Refer to the
01 to 40, 7D, 7E, and FF
reference manual.