Mitsubishi Electric 800 Series Installation Manualline page 33

Inverter for fans and pumps
Hide thumbs Also See for 800 Series:

Advertisement

Parameter Name
Induced voltage
706
constant (phi f)
707
Motor inertia (integer)
711
Motor Ld decay ratio
712
Motor Lq decay ratio
Starting resistance
717
tuning compensation
Starting magnetic
721
pole position
detection pulse width
Motor inertia
724
(exponent)
Motor protection
725
current level
Auto Baudrate/Max
726
Master
727
Max Info Frames
Device instance
728
number
(Upper 3 digits)
Device instance
729
number
(Lower 4 digits)
Second motor induced
738
voltage constant
(phi f)
Second motor Ld
739
decay ratio
Second motor Lq
740
decay ratio
Second starting
741
resistance tuning
compensation
Second motor
742
magnetic pole
detection pulse width
Second motor
743
maximum frequency
Second motor inertia
744
(integer)
Second motor inertia
745
(exponent)
Second motor
746
protection current
level
Second PID action
753
selection
Second PID control
754
automatic switch-over
frequency
Second PID action set
755
point
Second PID
756
proportional band
Second PID integral
757
time
Second PID
758
differential time
759
PID unit selection
Setting Range
Initial Value
0 to
9999
5000 mV/(rad/s),
9999
9999
10 to 999, 9999
9999
0 to 100%, 9999
0 to 100%, 9999
9999
9999
0 to 200%, 9999
0 to 6000 μs,
10000 to 16000 μs,
9999
9999
9999
0 to 7, 9999
100 to 500%,
9999
9999
255
0 to 255
1
1 to 255
0 to 419
0
(0 to 418)
0 to 9999
0
(0 to 4302)
0 to
5000 mV/(rad/s),
9999
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to 6000 μs,
9999
10000 to 16000 μs,
9999
9999
0 to 400 Hz, 9999
9999
10 to 999, 9999
9999
0 to 7, 9999
100 to 500%,
9999
9999
0, 10, 11, 20, 21,
50, 51, 60, 61, 70,
71, 80, 81, 90, 91,
0
100, 101, 1000,
1001, 1010, 1011,
2000, 2001, 2010,
2011
0 to 590 Hz,
9999
9999
0 to 100%,
9999
9999
0.1 to 1000%,
100 %
9999
0.1 to 3600 s,
1 s
9999
0.01 to 10 s,
9999
9999
0 to 43,
9999
9999
Parameter Name
Pre-charge fault
760
selection
Pre-charge ending
761
level
Pre-charge ending
762
time
Pre-charge upper
763
detection level
764
Pre-charge time limit
Second pre-charge
765
fault selection
Second pre-charge
766
ending level
Second pre-charge
767
ending time
Second pre-charge
768
upper detection level
Second pre-charge
769
time limit
Operation panel
774
monitor selection 1
Operation panel
775
monitor selection 2
Operation panel
776
monitor selection 3
4 mA input fault
777
operation frequency
778
4 mA input check filter
Operation frequency
779
during communication
error
Acceleration time in
791
low-speed range
Deceleration time in
792
low-speed range
Pulse increment
799
setting for output
power
Control method
800
selection
820
Speed control P gain 1
Speed control integral
821
time 1
822
Speed setting filter 1
Torque control P gain 1
824
(current loop
proportional gain)
Torque control
integral time 1
825
(current loop integral
time)
Torque detection
827
filter 1
828
Parameter for manufacturer setting. Do not set.
830
Speed control P gain 2
Speed control integral
831
time 2
832
Speed setting filter 2
Torque control P gain 2
834
(current loop
proportional gain)
BASIC OPERATION
Setting Range
Initial Value
0, 1
0
0 to 100%,
9999
9999
0 to 3600 s,
9999
9999
0 to 100%,
9999
9999
0 to 3600 s,
9999
9999
0
0, 1
0 to 100%,
9999
9999
0 to 3600 s,
9999
9999
0 to 100%,
9999
9999
0 to 3600 s,
9999
9999
1 to 3, 5 to 14, 17,
9999
18, 20, 23 to 25,
34, 38, 40 to 45,
9999
50 to 57, 61, 62,
64, 67 to 69,
81 to 96, 98,100,
9999
9999
0 to 590 Hz,
9999
9999
0 s
0 to 10 s
0 to 590 Hz,
9999
9999
0 to 3600 s, 9999
9999
9999
0 to 3600s, 9999
0.1, 1, 10, 100,
1 kWh
1000 kWh
20
9, 20, 109, 110
25%
0 to 1000%
0.333 s
0 to 20 s
9999
0 to 5 s, 9999
50%
0 to 500%
40 ms
0 to 500 ms
0 s
0 to 0.1 s
0 to 1000%, 9999
9999
9999
0 to 20 s, 9999
9999
0 to 5 s, 9999
9999
0 to 500%, 9999
27