Mitsubishi Electric 800 Series Installation Manualline page 28

Inverter for fans and pumps
Hide thumbs Also See for 800 Series:

Advertisement

BASIC OPERATION
Parameter Name
Online auto tuning
95
selection
Auto tuning setting/
96
status
100
V/F1 (first frequency)
V/F1 (first frequency
101
voltage)
V/F2
102
(second frequency)
V/F2 (second
103
frequency voltage)
V/F3
104
(third frequency)
V/F3 (third frequency
105
voltage)
V/F4
106
(fourth frequency)
V/F4 (fourth frequency
107
voltage)
108
V/F5 (fifth frequency)
V/F5 (fifth frequency
109
voltage)
Check valve
111
deceleration time
PU communication
117
station number
PU communication
118
speed
PU communication
stop bit length /
data length
119
PU communication
data length
PU communication
stop bit length
PU communication
120
parity check
PU communication
121
retry count
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication CR/
124
LF selection
Terminal 2 frequency
setting gain frequency
125
Simple
Simple
Simple
Terminal 4 frequency
setting gain frequency
126
Simple
Simple
Simple
PID control automatic
127
switchover frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
22
Setting Range
Initial Value
0, 1
0
0
0, 1, 11, 101
9999
0 to 590 Hz, 9999
0 V
0 to 1000 V
9999
0 to 590 Hz, 9999
0 V
0 to 1000 V
9999
0 to 590 Hz, 9999
0 V
0 to 1000 V
9999
0 to 590 Hz, 9999
0 V
0 to 1000 V
9999
0 to 590 Hz, 9999
0 to 1000 V
0 V
9999
0 to 3600 s, 9999
0
0 to 31
48, 96, 192, 384,
192
576, 768, 1152
1
0, 1, 10, 11
0
0, 1
1
0, 1
2
0 to 2
1
0 to 10, 9999
0, 0.1 to 999.8 s,
9999
9999
9999
0 to 150 ms, 9999
1
0 to 2
50 Hz
0 to 590 Hz
50 Hz
0 to 590 Hz
9999
0 to 590 Hz, 9999
0, 10, 11, 20, 21,
50, 51, 60, 61, 70,
71, 80, 81, 90, 91,
0
100, 101, 1000,
1001, 1010, 1011,
2000, 2001, 2010,
2011
0.1 to 1000%,
100%
9999
0.1 to 3600 s,
1 s
9999
0 to 100%,
9999
9999
Parameter Name
132
PID lower limit
133
PID action set point
134
PID differential time
Electronic bypass
135
sequence selection
MC switchover
136
interlock time
137
Start waiting time
Bypass selection at a
138
fault
Automatic switchover
frequency from
139
inverter to bypass
operation
Backlash acceleration
140
stopping frequency
Backlash acceleration
141
stopping time
Backlash deceleration
142
stopping frequency
Backlash deceleration
143
stopping time
Speed setting
144
switchover
PU display language
145
selection
Acceleration/
147
deceleration time
switching frequency
Stall prevention level
148
at 0V input
Stall prevention level
149
at 10V input
Output current
150
detection level
Output current
151
detection signal delay
time
Zero current detection
152
level
Zero current detection
153
time
Voltage reduction
154
selection during stall
prevention operation
RT signal function
155
validity condition
selection
Stall prevention
156
operation selection
157
OL signal output timer
AM terminal function
158
selection
Automatic switch-over
frequency range from
159
bypass to inverter
operation
User group read
160
Simple
Simple
Simple
selection
Setting Range
Initial Value
0 to 100%,
9999
9999
0 to 100%,
9999
9999
9999
0.01 to 10 s, 9999
0
0, 1
1 s
0 to 100 s
0.5 s
0 to 100 s
0
0, 1
0 to 60 Hz, 8888,
9999
9999
1 Hz
0 to 590 Hz
0.5 s
0 to 360 s
1 Hz
0 to 590 Hz
0.5 s
0 to 360 s
0, 2, 4, 6, 8, 10, 12,
4
102, 104, 106,
108, 110, 112
0 to 7
0 to 590 Hz,
9999
9999
110%
0 to 400%
120%
0 to 400%
110%
0 to 400%
0s
0 to 10s
0 to 400%
5%
0.5 s
0 to 10 s
1
0, 1, 10, 11
0
0, 10
0
0 to 31, 100, 101
0 s
0 to 25 s, 9999
1 to 3, 5 to 14, 17,
18, 21, 24, 34, 50,
1
52 to 54, 61, 62,
67, 69, 70,
86 to 96, 98
9999
0 to 10 Hz, 9999
0
0, 1, 9999

Advertisement

loading

This manual is also suitable for:

Fr-f846 e2-l2 seriesFr-f800-e