4.5.7.3 Right Ink Cartridge Holder
1.
Remove the Right IC Holder Cover.
2.
Remove the Top Cover.
(P.97)
3.
Remove the Upper Cover.
(P.100)
4.
Remove the Rear Frame.
(P.101)
5.
Remove the Right Frame.
(P.102)
6.
Remove the Maintenance Cartridge Cover.
7.
Remove the heater upper cover.
("4.5.8.3 Left Heater Duct/Right Heater Duct" Step5
8.
Remove the heater lower cover.
("4.5.8.3 Left Heater Duct/Right Heater Duct" Step6 (p189)
9.
Remove the CR frame cover.
("4.5.4.1 Self Sealing Valve" Step7 (p116)
10. Remove the Tube fixing plate.
("4.5.4.1 Self Sealing Valve" Step9 (p117)
11. Disconnect the cable from the three Ink end sensors.
Right Ink Cartridge
Holder
Ink end sensor
Figure 4-142. Releasing the cable
DX100 Service Manual
(P.99)
(P.103)
(p189))
to
Step 7
(p189))
to
Step 8
(p116))
to
Step 10
(p117))
4.5Disassembly and Assembly Procedure
12. Remove the four screws that secure the Right Ink Cartridge Holder.
A) Silver M3x8 P-tite screw : one piece
B) Silver M3x6 S-tite screw : one piece
C) Silver M3x4 Bind machine screw : two pieces
When removing the screw C, insert a screwdriver in the hole on the frame
C H E C K
to contact the screw shown
P O I N T
13. Slide the Right Ink Cartridge Holder in the direction of the arrow, and remove the
Right Ink Cartridge Holder.
A
Hole
Hole
C
C
Figure 4-143. Removing the Right Ink Cartridge Holder (1)
Figure
4-143.
Right Ink
Cartridge Holder
B
179