Zanussi ZBHC8 User Manual And Installation Instruction page 6

Thermo ventilation
Table of Contents

Advertisement

C. Window type method
Front cover size:
254mmX254mm
Window frame size:
210mmX219mm
Main body thickness:
160mm.
*Remark: Window type
installation must be
transverse installation.
The vent is under the
stainless steel cover
and cannot be covered
1.Install at the place of the aluminum framed window or replace the exhaust fan in the
bathroom
2.Fix the window kit to the frame of the aluminum window( waterproof glue must be used
for waterproof)
3.After connecting the power cord, embed the main body into the hole with screws.
Nails fixed hole
D. Wall mounted type method
1. Applicable for the bathroom without ceiling.
2. Fix the wall kit to the wall, then embed the main body on the wall kit.
3. Set the exhaust pipe(4" inner diameter 100mm) to the glass of window, and fix it to the
adaptor with tape or metal clamp.
4. Applicable size of the main body: 254mmX254mm,
Thickness of the main body: 160mm.
5.The minimum distance between the surrounding structures should be 50 cm.
≥20mm
The machine needs
≥20mm from the wall 2 sides
Wall
Main body fixed screw
-05-
≥20mm
Wall

Advertisement

Table of Contents
loading

Table of Contents