Configuring Upstream (Us) Classifier - Nokia 7368 Intelligent Services Access Manager ONT Product Manual

Hide thumbs Also See for 7368 Intelligent Services Access Manager ONT:
Table of Contents

Advertisement

Configure a G-2425G-B indoor ONT
Network configuration

Configuring Upstream (US) Classifier

Table 7-18 GRE Tunnel parameters (continued)
Field
WAN Interface
Primary Remote End
Secondary Remote End (optional)
Connected Remote End
Connectivity check
Traffic timeout to start pings
No. of retries before unreachable
3
Click Save.
E
ND OF STEPS
7.26
Configuring Upstream (US) Classifier
The US Classifier feature is used to create policies, classifiers, and classifier rules for upstream
traffic handling. This feature is available to admin users (super users) only.
A policy defines an action to be performed on a set of LAN or WAN packets. A policy can be created
at any time and then subsequently assigned to one or more classifiers.
A classifier is used to select key fields for which the classifier rules will be written. A classifier can be
created at any time and then subsequently assigned to one or more classifier rules.
A classifier rule is used to assign actions to a group of packets based on a set of parameters. A
classification rule must be created against a pre-defined classifier.
Up to 16 policies can be created, with up to 8 classifiers and 32 classifier rules.
1
Click Network US Classifier from the left pane in the GPON Home Gateway page, and
select the Policy tab.
All classifier policies are displayed in the policy table in the page.
110
Description
Select a WAN interface from the list.
GRE tunnels can only be created on HSI-enabled WAN interfaces.
Enter an IP address or FQDN that is unique in the system.
If the primary remote endpoint is down or unreachable, the secondary remote endpoint
becomes active, if configured.
The secondary remote endpoint remains active until it becomes unreachable, in which
case the primary remote endpoint becomes active again. Revertive mode is not
supported.
If both endpoints are unreachable, the GRE tunnel is declared down.
This field displays the current data traffic path for the GRE tunnel.
This feature is automatically selected by the system.
Enter the traffic timeout in seconds (2 to 1024).
Enter the number of retries before the tunnel is declared down (0 to 100).
Nokia – Proprietary and Confidential
Use pursuant to applicable agreements
3FE-48293-ACAA-TCZZA
7368 ISAM ONT
August 2020
Issue 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

G-2425g-b

Table of Contents