FXCPU Structured Programming Manual
(Application Functions)
Error
An operation error occurs when the value stored in a device specified in
"99,999,999".
Program example
In this program, double word [signed] data stored in a device specified in
and the data obtained by conversion is output to a device specified in
1) Function without EN/ENO(DINT_TO_BCD)
[Structured ladder]
g_dint1=20000
[ST]
g_dword1 := DINT_TO_BCD(g_dint1);
2) Function with EN/ENO(DINT_TO_BCD_E)
[Structured ladder]
g_bool1
g_dint1
[ST]
g_bool3 := DINT_TO_BCD_E(g_bool1, g_dint1, g_dword1);
DINT_TO_BCD
g_dword1=16#00020000
_DINT
DINT_TO_BCD_E
g_bool3
EN
ENO
_DINT
g_dword1
5 Applied Functions
5.1 Type Conversion Functions
is outside the range from "0" to
s
is converted into BCD data,
s
.
d
1
2
3
4
5
6
A
75