FXCPU Structured Programming Manual
(Application Functions)
Program example
In this program, word [signed] data stored in a device specified in
precision) data, and the data obtained by conversion is output to a device specified in
1) Function without EN/ENO(INT_TO_REAL)
[Structured ladder]
g_int1=5923
2) Function with EN/ENO(INT_TO_REAL_E)
[Structured ladder]
g_bool1
g_int1
INT_TO_REAL
g_real1=5923.0
a_Int
INT_TO_REAL_E
g_bool3
EN
ENO
a_Int
g_real1
is converted into float (single
s
[ST]
g_real1 := INT_TO_REAL(g_int1);
[ST]
g_bool3 := INT_TO_REAL_E(g_bool1, g_int1, g_real1);
5 Applied Functions
5.1 Type Conversion Functions
.
d