Configure Drive Parameters
and System Variables
This section provides information for accessing and changing parameters not
accessible through RSLogix 5000 software.

Tools for Changing Parameters

Most parameters are accessible through RSLogix 5000 software. Alternatives
include the DPI compatible Human Interface Module (HIM) and DriveExplorer
software.
Table 80 - Software For Changing Parameters
Method
Description
DriveExplorer software
DriveExplorer
Serial to SCANport adapter
HIM
Full numeric LCD HIM
(1) Refer to DriveExplorer Getting Results Manual, publication 9306-GR001, for instructions.
(2) Compatible catalog numbers include all 20-HIM-Ax.
Change Parameters with DriveExplorer Software
To navigate with DriveExplorer soft, refer to the example dialog box below. In
this example, the I/O Interface group folder is open, the Analog Outputs
parameter is selected, and the parameter elements are displayed in the box to the
right.
IMPORTANT
Figure 79 - DriveExplorer Software Example
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Configure and Start Up the Kinetix 6000 Drive System
Cat. No.
(1)
9306-4EXP02ENE
1203-SSS (Series B)
(2)
20-HIM-A3
Parameters are read-only when the SERCOS ring is active. You must
break the SERCOS ring to change parameters.
To save changes, perform a non-volatile save (NVS) prior to cycling
power.
Chapter 6
Firmware Revision
2.01 or later
3.004 or later
N/A