Chapter 7 Maintenance; Power On And Off Sequence - Fujitsu TeamPoS 2000 Installation And Maintenance Manual

Table of Contents

Advertisement

TeamPoS 2000

Chapter 7 MAINTENANCE

Caution: To prevent electric shock, confirm that the AC cable is removed from
Only trained personnel must perform the following:
1.
Vacuum all ventilation passageways on the control unit and peripherals. Ensure that
these passageways are open and free of dust and other debris that could restrict
airflow.
2.
Check the CPU chassis fan and PSU fan for proper operation annually. See BIOS
settings for typical fan speeds. If fan speed is approaching the low end, the fan should
be replaced. Fan speeds can be found under 'Clock and Sensor' for the A motherboard
and under 'Hardware Health Configuration'' for the M motherboard.
3.
Replace lead acid batteries every three years.
4.
If the model DT50/DT50II has the MICR option, check the function of, and clean, the
MICR annually.
7.1.

Power ON and OFF Sequence

This section presents the general procedures for powering ON and powering OFF the
TeamPoS 2000 control unit. The instructions in this section assume that the terminal,
operating system, and the application software have been installed. For any additional
power-up procedures dictated by the retail application, refer to the manuals provided with
the application software.
Caution: With the exception of USB peripherals, never disconnect or
90000291
the AC outlet anytime the covers are removed. Be sure to observe all
ESD precautions and power off procedures.
connect a peripheral while power is on its port. To avoid damage
to the control unit and peripherals, when connecting and
disconnecting peripherals from the Retail I/O or TeamCOMBO
Boards, turn power OFF with the ports OFF switch (see section 1.2),
the TeamPoS 2000 power switch in the front of the unit or by
disconnecting AC power.
Rev 3.0
MAINTENANCE MANUAL
7-1