  • Page 1 USER GUIDE    Humidity / Temperature Datalogger    Model RHT10  GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 2 Please  visit  our  website  (www.extech.com)  to  check  for  the  latest  version  of  this  User  Guide,  Product Updates, and Customer Support.    Features   Memory for 32,000 readings (16,000 temperature and 16,000 humidity readings)   Dew point indication via supplied Windows  Software   Grains per pound indication via optional Windows  Software (order RHT10‐SW)   Selectable data sampling rate: 2s, 5s, 10s, 30s, 1m, 5m, 10m, 30m, 1hr, 2hr, 3hr, 6hr, 12hr,  24hr   Status Indication via Red/Yellow LED and Green LED   USB Interface for Set‐up and Data Download   User‐Programmable Alarm Thresholds for Relative Humidity and Temperature   Long battery life  RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 3 Description  Protective cover  USB connector to PC port  Start button  RH and Temperature sensors  Alarm LED (red/yellow)  Record LED (green)  Mounting clip    RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 4: Operation

    CD‐ROM  drive,  then  find  and  double‐click  on  the  SETUP.EXE  file  included  on  the  program disk. Follow the on‐screen prompts to complete the installation.  Software Install  Run SETUP.up.exe and follow the defaults to install he RTH10 software  USB Driver Install    1. Open the root folder of the RHT10.    2. Open the folder   Driver\DriverUSBXPRESS and double‐click on USBXpressInstaller.exe.    3. Follow the default choices to load this USBXpress driver.    Note: When the RHT10 is connected to the USB port, the battery inside the device is discharged at  a higher rate than normal. To conserve battery life, do not leave the RHT10 connected to the USB  port for a prolonged period of time  RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 5 RUNNING THE GRAPHING SOFTWARE    With  the  RHT10  inserted  in  the  PC’s  USB  port,  double‐click  the  Datalogger  Graph  icon  on  your  desktop to launch the program.  The opening screen will appear as shown below.        Click on “Connect” to open the main screen,  Click on “About” to view the version number,        Click on “View File” to open an existing file,  Click on “Quit” to close the program.          RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at:...
  • Page 6: Menu Bar Description

      All  of  these  functions  are  described  in  the  following  paragraphs.   LOGGER SETUP        Click on the computer icon on the menu bar (2  from left) or select LOGGER SET from the LINK  pull‐down menu.  The Setup window will appear as shown below; descriptions for each field in  the Setup window are listed directly below the illustration:         The CURRENT TIME field will automatically synchronize with the PC date and time setting.   The MANUAL and INSTANT select buttons allow the user to start data logging immediately  when the Setup window is exited (INSTANT), or at a later time (MANUAL).   The LOGGER NAME field allows the user to select a unique name for the RHT10.   The SAMPLE POINTS field instructs the RHT10 to take a fixed number of readings.   The SAMPLE RATE pull‐down menu instructs the RHT10 to log readings at a specific rate.  RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 7   If INSTANT was selected in the SETUP window, the RHT10 begins logging at the instant the SETUP  button is pressed.  If MANUAL was selected, the RHT10 must be manually started by pressing and  holding the device’s yellow button for approx. 3 seconds, or until the two LEDs on the RHT10 flash  at the same time.    Logging will continue at the programmed sample rate until the number of readings (sample points)  specified in the Setup window is reached.    The  green  LED  flashes  once  per  sample  point  and  the  red  or  yellow  LED  flashes  when  user  programmed alarm limits are exceeded. For details, see LED status guide.    RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 8: Data Download

    .rec  file  for  use  in  this  program  only.    At  a  later  time,  the  user  can  select  SAVE‐AS and save the data as an Excel, Text, or Bitmap file (explained in next section).        In  the  screen  below  press  VIEW  to  see  the  data  graphically.  If  there  are  no  readings  currently  stored in the RHT10, the program will let the user know via a warning screen.          RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 9 ‘traces’);  the  RH  and  Dew  Point  are  represented  by  the  solid  yellow  and  green  lines,  respectively.  The  low  and  high  alarm  values  for  temperature  are  represented  by  the  dashed  red  traces; the corresponding alarms for humidity are represented by the dashed yellow traces.    RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 10: File Print

    Places  dots  on  the  traces  for  the  actual  data  points,  breaking  up  the  continuous nature of the trace.    FILE OPEN, FILE SAVE‐AS  To save the transferred data in a format other than the proprietary .rec format, click the SAVE AS  icon from the menu bar (4  from right) or select SAVE AS from the FILE pull‐down menu.  The data  can be saved in the following formats:    TEXT FILE (.txt)  EXCEL FILE (.xls)  BITMAP FILE (.bmp)    To open an existing data file for viewing on the data graph window, click on the FILE OPEN icon on  the menu bar (3  from left), or select FILE OPEN from the FILE pull‐down menu.  When prompted,  select a .rec file saved earlier.    FILE PRINT  To print a data graph window to a line or network printer, click on the printer icon or select PRINT  from the FILE pull‐down menu.  Note that color graph windows can be accurately printed on color  printers.    Note:  The RHT10 retains data in its internal memory until the user begins a new logging session.   Starting a new logging session clears all of the RHT10’s stored readings; be sure to save  previous data before starting a new logging session.    RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 11 GPP values are obtained only by purchasing and loading the optional RHT10‐SW software.     The optional software can be purchased through an Extech distributor using the part number  RHT10‐SW.   Note that the standard RHT10 software must be un‐installed before the optional RHT10‐SW  software can be installed.    To  view  GPP  data,  click  on  the  VIEW  menu  heading  and  scroll  down  to  the  SHOW  TRACES  tab.  Ensure that the GPP line is checked. If checked, the graph will display GPP data. If unchecked, the  graph will not show GPP data.    RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 12 When  the  battery  is  low,  all  operations  will  be  disabled  automatically.    NOTE:  Logging  automatically  stops  when  the  battery  weakens  (logged  data  will  be  retained).    The  supplied  software is required to restart logging and to download logged data.   ‡  When  both  temperature  and  relative  humidity  readings  exceed  alarm  level  simultaneously,  LED status indication alternates every other cycle.  RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at:...
  • Page 13: Specifications

    F)  ±1.8 F  Dew Point Temperature  Overall Range  ‐40 to 158 F (‐40 to 70 C)  Accuracy (25 C, 40 to 100%RH)  ±4.0 F (±2 C)  Grains per pound  1120 gpp (160g/kg) max.; Available only with optional RHT10‐SW software  Logging rate  Selectable sampling interval: From 2 seconds up to 24 hours  Operating temperature  ‐31 to 176 F (‐35 to 80 C)  Battery type  3.6V Lithium (1/2 AA) (SAFT LS14250, Tadiran TL‐5101 or equivalent)  Battery life  1 year (typ.) depending on logging rate, ambient temperature, & use of  Alarm LEDs  Dimensions/Weight  4x1x.9” (101x25x23mm) / 6oz (172g)  RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 14: Battery Replacement

    It  is  highly  recommended  that  the  battery  be  replaced  every  12  months,  or  prior  to  logging critical data.      The  RHT10  does  not  lose  its  stored  readings  when  the  battery weakens  or  when  the  battery  is  replaced;  the  data  logging  process  will  however  be  stopped  and  cannot  be  re‐started  until  the  battery has been replaced and the logged data has been downloaded to PC.   ...
  • Page 15: Warranty

    Warranty  FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year  from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the  instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit  the website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is  returned. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit.  This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of  specification, improper maintenance or repair, or unauthorized modification. FLIR Systems, Inc. specifically disclaims any implied  warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or  consequential damages. FLIR’s total liability is limited to repair or replacement of the product. The warranty set forth above is  inclusive and no other warranty, whether written or oral, is expressed or implied.  Calibration, Repair, and Customer Care Services  FLIR Systems, Inc. offers repair and calibration services for the Extech Instruments products we  sell. We offer NIST traceable calibration for most of our products. Contact our Customer Service  Department for information on calibration service availability. Annual calibrations should be  performed to verify meter performance and accuracy. Technical support and general customer  service is also provided, refer to the contact information provided below.  Copyright © 2014‐2016 FLIR Systems, Inc.  All rights reserved including the right of reproduction in whole or in part in any form  RHT10 HW_SW-en-US_V5.6.2 6/16 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...