To Selectively Store Branch Conditions (State Only) - HP 1660CP Series User Manual

Logic analyzers
Hide thumbs Also See for HP 1660CP Series:
Table of Contents

Advertisement

To selectively store branch conditions (State only)

Besides setting up your trigger levels to store anystate, no state, or some
subset of states, you can also choose whether or not to store branch
conditions. Branch conditions are always stored by default, and can make
tracing the analyzer's path through a complicated trigger easier. If you really
need the extra memory, however, it is possible to not store the branch
conditions.
You cannot set the analyzer to store only some branches in a trigger
sequence specification.
In the Analyzer Trigger menu, select Acquisition Control.
1
The Acquisition Control menu pops up. If the acquisition mode is set to
Automatic, the menu contains a single field and an explanation. If Acquisition
has been customized, it has 3 fields and a picture showing where the trigger
is currently placed in memory.
If the mode is Automatic, select the field and toggle it to Manual.
2
The menu now shows three fields and a picture.
Select the Branches Taken Stored field.
3
It toggles to Branches Taken Not Stored.
Select Done.
4
Acquisition Control Menu with Branches Field Highlighted
Using the Trigger Menu
To selectively store branch conditions (State only)
4–15

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Hp 1660cpHp 1661cpHp 1662cpHp 1663cp

Table of Contents