Mitsubishi Electric 800 Series Instruction Manual page 24

Hide thumbs Also See for 800 Series:

Advertisement

Rating
 FR-F860-00680 or higher
Model FR-F860-[ ]
Inverter capacity (kW)
Applicable motor capacity (kW)

Rated capacity (kVA)

Rated current (A)

Overload current rating

Rated voltage

Rated input
AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Rated input current (A)

Power supply capacity (kVA)

Protective structure (IEC 60529)
Cooling system
Approx. mass (kg)

The applicable motor capacity indicated is the maximum capacity applicable for use of the 4-pole standard motor.

The rated output capacity indicated assumes that the output voltage is 575 V.

When an operation is performed with the carrier frequency set to 3 kHz or more, and the inverter output current reaches the value indicated in the parenthesis, the
carries frequency is automatically lowered. The motor noise becomes louder accordingly.

The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the inverter
and motor to return to or below the temperatures under 100% load.

The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the maximum
point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about

The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and cables) affects the
rated input current.

The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input reactor and
cables).
24
SPECIFICATIONS
00680
01080
45
75
SLD
45
75
LD
45
75
SLD
68
108
LD
62
99
SLD
68 (57.8)
108 (91.8)
LD
62 (52.7)
99 (84.1)
SLD
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
120% 60 s, 150% 3 s
(inverse-time characteristics) at
LD
surrounding air temperature of
40°C
Three-phase 525 to 600 V
Three-phase 525 to 600 V 60 Hz
472 to 660 V 60 Hz
±5%
SLD
87
108
LD
79
99
SLD
86.8
107.6
LD
79.1
98.6
Open type (IP00)
Forced air cooling
36
41
01440
01670
02430
90
110
132
110
110
185
90
110
150
144
167
242
131
152
221
144 (122)
167 (141)
243 (206)
131 (122)
152 (129)
221 (187)
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
144
167
243
131
152
221
143
166
242
130
151
220
52
52
55
02890
03360
160
220
220
260
185
220
288
335
254
303
289 (245)
336 (285)
255 (216)
304 (258)
289
336
255
304
288
335
254
303
112
115
.
04420
250
335
300
441
401
442 (375)
402 (341)
442
402
440
400
153