Full Gauge MT-444 eXpress Manual

Full Gauge MT-444 eXpress Manual

Digital cooling controller with touch screen keys

Advertisement

BEFORE INSTALLING THE CONTROLLER, WE RECOMMEND READING THROUGH THE
ENTIRE INSTRUCTION MANUAL IN ORDER TO AVOID POSSIBLE DAMAGE TO THE
PRODUCT.
PRECAUTIONS WHEN INSTALLING THE PRODUCT:
Before performing any procedure on this instrument, disconnect it from the mains;
Ensure that the instrument has adequate ventilation and avoid installation in panels containing
devices that may cause it to operate outside the specified temperature limits;
Install the product away from sources that may generate electromagnetic disturbances such as:
motors, contactors, relays, solenoid valves, etc;
AUTHORIZED SERVICE:
The installation or maintenance of the product must be performed by qualified professionals only;
ACCESSORIES:
Only use original Full Gauge Controls accessories.
If you have any questions, please contact technical support.
DUE TO YOUR CONSTANT EVOLUTION, THE FULL GAUGE CONTROLS RESERVES THE RIGHT TO CHANGE
THE INFORMATION CONTAINED IN THIS MANUAL AT ANY TIME WITHOUT NOTICE.
1. DESCRIPTION
The MT-444 eXpress is a digital controller designed specifically for cooling. The touch screen keys can
select the desired Preset (3 options); enable/disable the energy saving mode, among other functions. It has a
normal operating setpoint and a power-saving setpoint for each one of the three Presets, with their respective
hysteresis.
While the MT-444 eXpress offers a default solution for most applications, the MT-444 V-eXpress
offers a distinct characteristic, the power grid voltage meter. Using the True-RMS strain gauge, it is capable of
protecting the compressor against activations with improper voltage, whether it is high or low. Similarly, when
the power grid voltage is higher or lower than the maximum or minimum voltage setup, the compressor output
will be automatically switched off for protection.
2. APPLICATION
- Beverage displays;
- Refrigeration cabinets.
3. TECHNICAL SPECIFICATIONS
- Power Supply: 230Vac ±10% (50/60 Hz) or on the version 115Vac ±10% (50/60 Hz)
- Setpoint Temperature: -50 to 60ºC or -58 to 99ºF
- Operation Temperature: 0 to 45ºC (32 to 113ºF)
- Resolution: 0.1ºC between -9.9 and 9.9ºC and 1ºC on the remainder of the range
1ºF on all the range
- Maximum current of the relays: 10(8) A/ 250Vac 1HP–compressor output
7A/ 250Vac – defrost output
3(2) A/ 250Vac – 1/10HP– fan output
2(2) A/ 250Vac – light output
- Digital input: input for open-door detection (dry contact type)
- Operating humidity: 10 to 90% RH (with no condensation)
- Frontal dimension (with frame): 105x55x90 mm (WxHxD)
- Frontal cutouts dimension: 91x45 mm
- Base module dimension: 113x87.5x32 mm (WxHxD)
4. INDICATORS AND KEYS
6
5
4
3
2
1
Power-Saving Mode LED indicator
1
Light LED indicators
2
3
LED indicator for pre-defrost and defrost (on) or draining (blinking)
4
Fan LED indicators
5
Compressor LED indicators
6
Power-Saving Mode Key
7
Temperature unit LED indicator
8
Plus Key / Preset 1
9
Set Key / Preset 2
10
Minus Key / Preset 3
VER. 01
DIGITAL COOLING CONTROLLER WITH
TOUCH SCREEN KEYS
Power-saving
Touch
Manual
Function
mode
screen
Defrost
blocking
WARNING
7
8
9
10
Audible
Turn control
Serial
Alarm
functions off
Programming
5. BASIC OPERATIONS
NOTE: If L3 is at 0, the first touch will be to enable the keyboard.
5.1 Change Preset
To select the desired preset, press and hold the corresponding key for 2s, until the [Pr] screen appears, and
then release it.
Press and hold for 2 sec.
5.2 Turning power-saving mode on/off
To turn the energy saving mode on/off press and hold the
then release it.
Press and hold for 2 sec.
5.3 Silencing the alarm
To silence the audible alarm, tap any of the keys , or .
Tap
5.4 Manual Defrost
To start/stop a manual defrost, regardless of the schedule, press and hold the
message appears, and then release it. The [On] message will appear when it has started and the [OF]
message when it has been stopped.
Press and hold for 10 sec.
5.5 Display process stage and the current desired temperatures
(setpoint)
To see which process stage is underway, press and hold the
and then release it. The stage of the process in progress will be displayed, showing the desired temperature
(setpoint) in use, in relation to the current operating mode (normal/power-saving).
Press and hold for 4 sec.
Preset 1
Preset 2
Preset 3
release
the key
key for 2s, until the [EC] message appears, and
On
release
Off
the key
$ % &
%
key for 10s, until the [dF]
On
release
Off
the key
&
key for 4s, until the [St] message appears,
Displays the
Shows the current desired
current stage
temperature (setpoint)
Fan delay
release
Cooling
the key
Pre-defrost
Defrost
Draining
ex: (2.0ºC)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MT-444 eXpress and is the answer not in the manual?

Questions and answers

Rodrigo Gaydeczka
February 18, 2025

Como regular a temperatura do Full gauge MT 444 teclas sensíveis ao toque? Preciso deixar em -4 ..está em -6°C

1 comments:
Mr. Anderson
February 18, 2025

To adjust the temperature on the Full Gauge MT-444 eXpress from -6°C to -4°C, follow these steps:

1. Access the desired temperature (setpoint) settings.
2. Locate the current setpoint, which is -6°C.
3. Increase the setpoint to -4°C.
4. Save the new setting.

Ensure that the new value stays within the allowed temperature range to prevent excessive energy consumption.

This answer is automatically generated

Summary of Contents for Full Gauge MT-444 eXpress

  • Page 1 1. DESCRIPTION 5.2 Turning power-saving mode on/off The MT-444 eXpress is a digital controller designed specifically for cooling. The touch screen keys can To turn the energy saving mode on/off press and hold the key for 2s, until the [EC] message appears, and select the desired Preset (3 options);...
  • Page 2: Advanced Operations

    5.6 Display the current temperature on sensor 2 (evaporator) and 6. ADVANCED OPERATIONS power grid voltage NOTE: If L3 is at 0, the first touch will be to enable the keyboard. key for 4s, until the [S2] message appears, and then release it. The following Press and hold the 6.1 Display the setup information will be shown:...
  • Page 3 CELSIUS (FAHRENHEIT) FUNCTION DESCRIPTION UNIT DEFAULT This is the value that will be added to the current preset setpoint after the time set in [P7]. Example: If [t1]=[3. 0 ] (setpoint), [h1]=[2. 0 ] (differential) and [h7]=[1. 0 ] (antifreeze), Antifreeze safety differential temperature [h7] 0.1 (01)
  • Page 4 CELSIUS (FAHRENHEIT) FUNCTION DESCRIPTION UNIT DEFAULT Fan OFF Time if [F1] and [F2] are in automatic This is the amount of time the fan will remain OFF if [F1] and [F2] are configured as [F4] min. mode ([,A]) automatic, while the compressor is off. The fan can be set to remain activated or deactivated in the period when the door is kept Fan operation when opening the door [F5]...
  • Page 5: Frequently Asked Questions

    Actions: Check the power supply voltage of the instrument. any time and unload onto a production line (of the same controller). The MT-444 eXpress and MT-444 V-eXpress controller includes an USB connection to load or unload setups: Reason: Maximum compressor ON time exceeded without reaching the control - USB: can be connected to the computer via the USB port.
  • Page 6: Installation

    If in doubt, please contact Full Gauge Controls. Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) year warranty, as of the date of the consigned sale, as stated on the invoice. They are guaranteed against manufacturing defects that make them unsuitable or inadequate for their intended use.