Download Print this page
Full Gauge TC-900 E Operation Manual

Full Gauge TC-900 E Operation Manual

Digital controller for refrigeration and defrost

Advertisement

Quick Links

1. DESCRIPTION
For frozen products, it automates the defrost processes according to the need of installation (smart
defrost). The ambient temperature control has a normal setpoint and an economic setpoint, apart from
the fast freezing function and alarm functions indicating open door. Its 16A relay directly controls
compressors of up to 1HP and its defrost output has a current capacity of 10A.
It also features a digital filter, intended to simulate a mass increase in the ambient sensor (S1), thus
increasing its response time (thermal inertia) and avoiding unnecessary drives of the compressor. It also
includes a smart key, lock system and a control functions shutdown mode.
To drive inductive loads (motors and pumps) of up to 2HP, use the
2. APPLICATION
• Cold Storage Rooms
• Display freezers
3. TECHNICAL SPECIFICATIONS
- Power supply: TC-900 E POWER: 115 or 230Vac ±10% (50/60Hz)
TC-900 EL POWER: 12 or 24Vac/dc ±10%
- Control temperature: -50°C to 105°C / -58°F to 221°F
- Operating temperature: 0 to 50°C / 32 to 122°F
- Load current (outputs): COMP: 12(8)A / 240Vac 1HP
DEFR: 10A / 240Vac 1/4HP
FANS: 5(3)A / 240Vac
- Operating humidity: 10 to 85 %RH (without condensation)
- Dimensions: 76 x 34 x 77 mm (WxHxD)
- Dimensions of the clipping for fixing of the instrument: 71 ± 0,5 x 29 ± 0,5 mm (see item 5)
4. INDICATIONS AND KEYS
3
4
5
2
1
e
TC-900
POWER
Set key
1
Quick Access Menu Key
2
Compressor output indication LED
3
Fan/defrost indication LED 2
4
Defrost indication LED
5
Functions lock indication LED
6
Control functions shutdown indication LED
7
Temperature unit indication LED
8
Increase key
9
Decrease key
10
5. INSTALLATION - ASSEMBLING
Panel
(Side View)
ATTENTION
FOR INSTALLATIONS WHERE A SEALING IS REQUIRED TO AVOID LIQUID CONTACT, THE CUT FOR THE CONTROLLER
MUST BE OF 70,5x29mm MAXIMUM. THE SIDE LOCKS MUST BE FIXED SO IT PRESSES THE RUBBER SEALING
AVOIDING INFILTRATION BETWEEN THE CUT AND THE CONTROLLER.
5.1 INSTALLATION - ELECTRICAL CONNECTIONS
Connection 115 Vac
D1/S3
D2
5 6 7 8
9 10 11 12 13 14 15 16 17
1
2 3 4
e
TC-900
POWER
DIGITAL CONTROLLER FOR
REFRIGERATION AND DEFROST
Fast Freezing
Functions
Control functions
lockdown
shutdown
e
TC-900
2HP.
6
7
8
71
± 0,5
mm
Dimension of the clipping
for fixing of the
instrument in panel
Panel (Front View)
115 Vac
IP 65
FRONT
Serial
Protection
programming
level
6. OPERATIONS
6.1 Quick Access Menu Map
To access or navigate the quick access menu using the
displaying the temperature. For every touch, the next function in the list is displayed. To confirm, use the
/
(short press) key.
FAST FREEZING (ON/OFF)
;
e
TC-900
POWER
ECONOMIC SETPOINT(ON/OFF)
;
e
TC-900
POWER
DEFROST (ON/OFF)
;
e
TC-900
POWER
FUNCTIONS LOCKDOWN
;
e
TC-900
POWER
CONTROL FUNCTIONS
(ON/OFF)
9
;
e
10
TC-900
POWER
NORMAL SETPOINT
;
e
TC-900
POWER
6.2 QUICK ACCESS KEYS MAP
When the controller is on temperature display, the following keys serve as a shortcut for the following
functions:
/ <
Pressed for 2 seconds: Setpoint adjustment.
Short press: Displays process status.
<
Pressed for 2 seconds: inhibits audible alarm.
<
Short press: display of minimum and maximum measurement records.
<
Pressed for 2 seconds: when displaying records, it cleans the history.
;
Enters the quick access menu.
<
<
and
Enters the functions selection.
6.3 BASIC OPERATIONS
6.3.1Setting the desired temperature
To access the setpoints setup menu press
display followed by the normal setpoint set value. Use the
/
pressing
. Immediately, the message [SP-e] appears indicating the setting of the economic
setpoint. Again, use the
[----] indication signals the setup completion. The setpoints can also be adjusted individually in the
quick access menu.
Connection 230 Vac
D1/S3
D2
5 6 7 8
9 10 11 12 13 14 15 16 17
1
2 3 4
PO W ER
PO W ER
e
e
TC -9 00
TC -9 00
;
(short press) key while the controller is
/
for 2 seconds. The message [SP,,] will appear on the
>
<
or
to modify the value and confirm by
>
<
or
keys to modify the value and confirm by pressing
230 Vac
evolution
EXIT FUNCTION
;
e
TC-900
POWER
FUNCTION SELECTION
;
e
TC-900
POWER
ERASE MAX. AND MIN.
VALUES
;
e
TC-900
POWER
MAX. AND MIN. TEMPERATURE
RECORD
;
e
TC-900
POWER
ECONOMIC SETPOINT
;
e
TC-900
POWER
/
. Finally, the
*The sensor S1 (black)
must be in the ambient.
*The sensor S2 (gray) must
be placed in the evaporator
through metallic cramp.

Advertisement

loading
Need help?

Need help?

Do you have a question about the TC-900 E and is the answer not in the manual?

Questions and answers

CHEE LIM
January 27, 2025

how to change from celsius to Fahrenheit

Summary of Contents for Full Gauge TC-900 E

  • Page 1 • Display freezers ECONOMIC SETPOINT(ON/OFF) EXIT FUNCTION 3. TECHNICAL SPECIFICATIONS - Power supply: TC-900 E POWER: 115 or 230Vac ±10% (50/60Hz) TC-900 EL POWER: 12 or 24Vac/dc ±10% - Control temperature: -50°C to 105°C / -58°F to 221°F TC-900 POWER...
  • Page 2: Advanced Operations

    Connection 12 Vac/dc Connection 24 Vac/dc D1/S3 D1/S3 5 6 7 8 5 6 7 8 9 10 11 12 13 14 15 16 17 9 10 11 12 13 14 15 16 17 2 3 4 2 3 4 *The sensor S1 (black) must be in the ambient.
  • Page 3: Description Of Parameters

    CELSIUS FAHRENHEIT Description Unit Standard Unit Standard F07] Economic setpoint control differential (hysteresis) º C °F [,F08] Minimum set point allowed to the end user º C °F [,F09] Maximum set point allowed to the end user º C °F [,F10] Time for closed door to enter economy mode 0 (no)
  • Page 4 F34 - Evaporator temperature (S2 / S3) for fan return after drainage: F16 - Fan operating mode: After drainage starts the fan-delay cycle. The compressor is driven immediately, because the evaporator This parameter allows setting how the fan output will behave during the cooling cycle. In this case, its temperature is high, but the fan is only activated after the temperature in the evaporator decreases from operating options consider the compressor's output status and the setpoint the instrument is operating the set value.
  • Page 5: Environmental Information

    8.3 Extension Frame The Full Gauge Controls extension frame allows the installation of Evolution / Ri line with measures F56 - Control functions shutdown: 76x34x77 mm (dimensions of the clipping for fixing in the extension frame is 71x29mm) in varied It authorizes the shutdown of the control functions (see section 6.3.8).