Operation Mode Read/Write; Set Frequency Read; Terminal Input Read; Inverter Reset - Mitsubishi Electric 800 Series Instruction Manual

Plug-in option, profibus-dp communication function
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

7.6.3

Operation mode read/write

Read/write of the operation mode can be performed from the master.
PNU
P3
Operation mode read/write
7.6.4

Set frequency read

The frequency set to the inverter can be read from the master.
PNU
P4.1
Set frequency (RAM) read
Set frequency (EEPROM)
P4.2
read
7.6.5

Terminal input read

Analog input values of terminals 2, 4 can be read.
PNU
P5.1
Terminal 2 input value read
P5.2
Terminal 4 input value read
7.6.6

Inverter reset

The inverter can be reset from the master.
PNU
P6
Inverter reset
• The inverter maintains the resetting status while reset is requested.
• When Pr.75 Reset selection/disconnected PU detection/PU stop selection = "1, 3, 15, 17, 10001, 10003, 10015, or
10017", reset is enabled only during an inverter error.
Item
External operation mode: H10
PU operation mode: H11 (For writing, when "6" is set in Pr.79)
Network operation mode: H14
Item
Set frequency (RAM) is read.
Set frequency (EEPROM) is read.
Item
Terminal 2 input value (%) is read.
Terminal 4 input value (%) is read.
Item
The inverter is reset after the data was written from the master.
Data definition
Data definition
Data definition
Data definition
PPO TYPE SUPPORT SPECIFICATION
Data type
Us16
Data type
AUs16
AUs16
Data type
AUs16
AUs16
Data type
Us16
7
53