Huawei PDU8000 Quick Manual page 25

Ups modular input power distribution cabinet (single cabinet)
Hide thumbs Also See for PDU8000:
Table of Contents

Advertisement

Port Description
Power input (L/N)
Power input (PE)
B
Power Cable Specifications
YJV5 cables are recommended. The conduct working temperature is 90ºC, and the ambient
temperature is 40ºC. The following table describes the specifications.
PDC BOM
Description
Number
PDC-800 A
MCCB input
02114870
cabinet-
single
cabinet
Rated current
Bolt Specifications
(A)
63
OT-M6
160
DT/OT-M10
250
DT-M12
400
DT-M12
630
(MCCB:DT-M12/ATS:DT-M16)
800
DT-M16
1250
DT-M16
1600
DT-M16
63
OT-M6
160
DT/OT-M10
250
DT-M10
400
DT-M10
630
DT-M10
800
DT-M12
1250
DT-M12
1600
DT-M12
BOM
Category
Number
Mains
input
25030866
power
cable
14170092
Mains
input
power
cable
14170077
terminal
BOM Description
Electronic/Electric Cable, 600 V,
ZA-YJV, (4x240 + 1x120) mm
Black (4+1 Cores: Yellow, Green,
Red, Blue, Black), 599 A, CE
Naked Crimping Terminal, JG,
300 mm
2
, M16, Tin Plating
Naked Crimping Terminal, JG,
150 mm
, M12, 440 A, Tin
2
Plating
24
Recommended
Torque (N· m)
4.5
27
47
47
47/120
120
120
120
4.5
27
27
27
27
47
47
47
Quantity
2
,
2 x Cable
length
18 (2 for
redundancy)
5 (1 for
redundancy)

Advertisement