Calibrating The Hs5E Control System - Bosch REXROTH A4 Series Instruction Manual

Axial piston variable pump with hs5e pilot control valve
Table of Contents

Advertisement

Fig. 28: Good control
If the control behavior is good, no measures need to be taken.

8.1.8 Calibrating the HS5E control system

With regular calibration, the calibration functions of the HS5E make it possible
to achieve consistent system behavior by compensating long-term drifts.
You can only carry out the points below in conjunction with a pressure sensor.
We recommend calibrating the HS5E control systemin the following order:
1.
Calibration of the pressure transducer (provided by the customer)
2.
Calibration of the valve offset
3.
Calibration of the swivel angle sensor's offset
4.
Calibration of the swivel angle sensor's gain
5.
Calibration of leakage compensation
You can find further information about configuring and activating the calibration
functions in the functional description of the HydraulicDrive firmware (data
sheet 30338).
RE 92076-01-B/10.2017, A4... with HS5E pilot control valve/Series 3x, Bosch Rexroth AG
Pressure command value
Good control
Time
Commissioning
75/104