FLOOR-STANDING Inverter Heat Pump
PERFORMANCE DATA
COOLING operation
MFZ-KA50VA/SUZ-KA50VAR2.TH Rated frequency 76Hz
CAPACITY : 4.8(kW) SHF : 0.63 INPUT : 1550(W)
INDOOR INDOOR
DB (°C) WB (°C)
Q
SHC SHF INPUT
21
18
4.70 2.12 0.45
21
20
4.94 1.63 0.33
22
18
4.70 2.30 0.49
22
20
4.94 1.83 0.37
22
22
5.23 1.31 0.25
23
18
4.70 2.49 0.53
23
20
4.94 2.03 0.41
23
22
5.23 1.52 0.29
24
18
4.70 2.68 0.57
24
20
4.94 2.22 0.45
24
22
5.23 1.73 0.33
24
24
5.52 1.16 0.21
25
18
4.70 2.87 0.61
25
20
4.94 2.42 0.49
25
22
5.23 1.94 0.37
25
24
5.52 1.38 0.25
26
18
4.70 3.06 0.65
26
20
4.94 2.62 0.53
26
22
5.23 2.15 0.41
26
24
5.52 1.60 0.29
26
26
5.81 0.99 0.17
27
18
4.70 3.25 0.69
27
20
4.94 2.82 0.57
27
22
5.23 2.35 0.45
27
24
5.52 1.82 0.33
27
26
5.81 1.22 0.21
28
18
4.70 3.43 0.73
28
20
4.94 3.02 0.61
28
22
5.23 2.56 0.49
28
24
5.52 2.04 0.37
28
26
5.81 1.45 0.25
29
18
4.70 3.62 0.77
29
20
4.94 3.21 0.65
29
22
5.23 2.77 0.53
29
24
5.52 2.26 0.41
29
26
5.81 1.68 0.29
30
18
4.70 3.81 0.81
30
20
4.94 3.41 0.69
30
22
5.23 2.98 0.57
30
24
5.52 2.48 0.45
30
26
5.81 1.92 0.33
31
18
4.70 4.00 0.85
31
20
4.94 3.61 0.73
31
22
5.23 3.19 0.61
31
24
5.52 2.70 0.49
31
26
5.81 2.15 0.37
32
18
4.70 4.19 0.89
32
20
4.94 3.81 0.77
32
22
5.23 3.40 0.65
32
24
5.52 2.93 0.53
32
26
5.81 2.38 0.41
NOTE
Q : Total capacity (kW)
SHC : Sensible heat capacity (kW)
C-254
OUTDOOR
35
40
Q
SHC SHF INPUT
1519
4.32 1.94 0.45
1581
4.61 1.52 0.33
1519
4.32 2.12 0.49
1581
4.61 1.70 0.37
1643
4.90 1.22 0.25
1519
4.32 2.29 0.53
1581
4.61 1.89 0.41
1643
4.90 1.42 0.29
1519
4.32 2.46 0.57
1581
4.61 2.07 0.45
1643
4.90 1.62 0.33
1705
5.18 1.09 0.21
1519
4.32 2.64 0.61
1581
4.61 2.26 0.49
1643
4.90 1.81 0.37
1705
5.18 1.30 0.25
1519
4.32 2.81 0.65
1581
4.61 2.44 0.53
1643
4.90 2.01 0.41
1705
5.18 1.50 0.29
1767
5.47 0.93 0.17
1519
4.32 2.98 0.69
1581
4.61 2.63 0.57
1643
4.90 2.20 0.45
1705
5.18 1.71 0.33
1767
5.47 1.15 0.21
1519
4.32 3.15 0.73
1581
4.61 2.81 0.61
1643
4.90 2.40 0.49
1705
5.18 1.92 0.37
1767
5.47 1.37 0.25
1519
4.32 3.33 0.77
1581
4.61 3.00 0.65
1643
4.90 2.59 0.53
1705
5.18 2.13 0.41
1767
5.47 1.59 0.29
1519
4.32 3.50 0.81
1581
4.61 3.18 0.69
1643
4.90 2.79 0.57
1705
5.18 2.33 0.45
1767
5.47 1.81 0.33
1519
4.32 3.67 0.85
1581
4.61 3.36 0.73
1643
4.90 2.99 0.61
1705
5.18 2.54 0.49
1767
5.47 2.02 0.37
1519
4.32 3.84 0.89
1581
4.61 3.55 0.77
1643
4.90 3.18 0.65
1705
5.18 2.75 0.53
1767
5.47 2.24 0.41
SHF : Sensible heat factor
INPUT : Total power input (W)
DB(°C)
46
Q
SHC SHF INPUT
1612
3.98 1.79 0.45
1659
4.27 1.41 0.33
1612
3.98 1.95 0.49
1659
4.27 1.58 0.37
1736
4.56 1.14 0.25
1612
3.98 2.11 0.53
1659
4.27 1.75 0.41
1736
4.56 1.32 0.29
1612
3.98 2.27 0.57
1659
4.27 1.92 0.45
1736
4.56 1.50 0.33
1783
4.90 1.03 0.21
1612
3.98 2.43 0.61
1659
4.27 2.09 0.49
1736
4.56 1.69 0.37
1783
4.90 1.22 0.25
1612
3.98 2.59 0.65
1659
4.27 2.26 0.53
1736
4.56 1.87 0.41
1783
4.90 1.42 0.29
1845
5.14 0.87 0.17
1612
3.98 2.75 0.69
1659
4.27 2.44 0.57
1736
4.56 2.05 0.45
1783
4.90 1.62 0.33
1845
5.14 1.08 0.21
1612
3.98 2.91 0.73
1659
4.27 2.61 0.61
1736
4.56 2.23 0.49
1783
4.90 1.81 0.37
1845
5.14 1.28 0.25
1612
3.98 3.07 0.77
1659
4.27 2.78 0.65
1736
4.56 2.42 0.53
1783
4.90 2.01 0.41
1845
5.14 1.49 0.29
1612
3.98 3.23 0.81
1659
4.27 2.95 0.69
1736
4.56 2.60 0.57
1783
4.90 2.20 0.45
1845
5.14 1.69 0.33
1612
3.98 3.39 0.85
1659
4.27 3.12 0.73
1736
4.56 2.78 0.61
1783
4.90 2.40 0.49
1845
5.14 1.90 0.37
1612
3.98 3.55 0.89
1659
4.27 3.29 0.77
1736
4.56 2.96 0.65
1783
4.90 2.59 0.53
1845
5.14 2.11 0.41
DB : Dry-bulb temperature
WB : Wet-bulb temperature
M series
1674
1752
1674
1752
1798
1674
1752
1798
1674
1752
1798
1860
1674
1752
1798
1860
1674
1752
1798
1860
1922
1674
1752
1798
1860
1922
1674
1752
1798
1860
1922
1674
1752
1798
1860
1922
1674
1752
1798
1860
1922
1674
1752
1798
1860
1922
1674
1752
1798
1860
1922