Mitsubishi Electric M Series Manual page 161

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

M series
MSZ-FD25VA
MSZ-GE22VA
MSZ-FD25VAS
MSZ-GE25VA
MSZ-FD35VA
MSZ-GE35VA
MSZ-FD35VAS
MSZ-GE42VA
MSZ-FD50VA
MSZ-GE50VA
MSZ-FD50VAS
MSZ-FD
L
AREA R
POWER
Abnormal
No.
Operation indicator lamp
point
All lamps flash at the same time.
Attachment
of the
0.5-second ON
1
horizontal
vane
0.5-second OFF
MSZ-FD25VA
MSZ-GE22VA
MSZ-FD25VAS
MSZ-GE25VA
MSZ-FD35VA
MSZ-GE35VA
MSZ-FD35VAS
MSZ-GE42VA
MSZ-FD50VA
MSZ-GE50VA
MSZ-FD50VAS
MSZ-FD
L
AREA R
POWER
Abnormal
No.
Operation indicator lamp
point
POWER lamp is lighted.
MXZ type
AREA lamps flash.
Operation
1
mode
setting
2.5-second OFF
MSZ-GE
OPERATION INDICATOR
Abnormal
No.
Operation indicator lamp
point
Upper lamp lights and lower lamp flashes.
MXZ type
Operation
1
mode
setting
2.5-second OFF
MSZ-SF
OPERATION INDICATOR
Abnormal
No.
Operation indicator lamp
point
Left lamp lights and right lamp flashes
MXZ type
Operation
1
mode
2.5-second OFF
setting
MSZ-FD25VA
MSZ-FD25VAS
MSZ-FD35VA
MSZ-FD35VAS
MSZ-FD50VA
MSZ-FD50VAS
L
AREA R
POWER
Abnormal
No.
Operation indicator lamp
point
PLASMA lamp flashes.
2-time flash
PLASMA
1
control
2.5-second OFF
MSZ-GE
OPERATION INDICATOR
CLEAN PLASMA
Symptom
Indoor unit
and outdoor
unit do not
operate.
MSZ-GE60VA
MSZ-GE71VA
CLEAN PLASMA
Symptom
Outdoor unit
operates but
indoor unit
does not
operate.
Symptom
Outdoor unit
operates but
indoor unit
does not
operate.
Symptom
Outdoor unit
operates but
indoor unit
does not
operate.
CLEAN PLASMA
Symptom
Indoor unit
and outdoor
unit do not
operate.
WALL-MOUNTED Inverter Heat Pump
Condition
The electricity is not conducted to the interlock
switch (Fan) of the horizontal vane.
MSZ-SF15VA
MSZ-SF20VA
Condition
The operation mode of the each indoor unit is
differently set to COOL (includes DRY) and
HEAT at the same time, the operation mode of
the indoor unit that has operated at first has the
priority.
Condition
The operation mode of the each indoor
unit is differently set to COOL (includes DRY)
and HEAT at the same time, the operation
mode of the indoor unit that has operated at
first has the priority.
Condition
The operation mode of the each indoor unit is
differently set to COOL (includes DRY) and
HEAT at the same time, the operation mode
of the indoor unit that has operated at first
has the priority
Condition
PLASMA operation can not be turned OFF
even if the PLASMA operation is turned OFF
with remote controller.
C-159