Mitsubishi Electric M-SERIES Manual

Mitsubishi Electric M-SERIES Manual

Single zone systems
Hide thumbs Also See for M-SERIES:

Advertisement

M-SERIES SINGLE ZONE SYSTEMS
MSY-GE-NA COOLING ONLY Wall-Mount Air System
1. INDOOR UNITS ............................................................................................................................................MXZ-GE-NA-3
2. OUTDOOR UNITS ........................................................................................................................................MXZ-GE-NA-4
3. SYSTEM ........................................................................................................................................................MXZ-GE-NA-5
3-1. SPECIFICATIONS .....................................................................................................................................MXZ-GE-NA-6
MSY-GE09NA-8 MSY-GE12NA-8 MSY-GE15NA-8 MSY-GE18NA-8 ......................................................MXZ-GE-NA-6
MSY-GE24NA ..............................................................................................................................................MXZ-GE-NA-7
MUY-GE09NA MUY-GE12NA .....................................................................................................................MXZ-GE-NA-8
MUY-GE15NA-1 MUY-GE18NA-1 ..............................................................................................................MXZ-GE-NA-9
MUY-GE24NA ...........................................................................................................................................MXZ-GE-NA-10
Efficiency Ratings ......................................................................................................................................MXZ-GE-NA-11
3-2. EXTERNAL DIMENSIONS.......................................................................................................................MXZ-GE-NA-12
MSY-GE09NA-8 MSY-GE12NA-8 MSY-GE15NA-8 MSY-GE18NA-8 ....................................................MXZ-GE-NA-12
MSY-GE24NA ............................................................................................................................................MXZ-GE-NA-13
MUY-GE09NA MUY-GE12NA MUY-GE15NA-1 ......................................................................................MXZ-GE-NA-14
MUY-GE18NA-1 ........................................................................................................................................MXZ-GE-NA-15
MUY-GE24NA ...........................................................................................................................................MXZ-GE-NA-16
3-3. CENTER OF GRAVITY ............................................................................................................................MXZ-GE-NA-17
3-4. ELECTRICAL WIRING DIAGRAMS.........................................................................................................MXZ-GE-NA-18
MSY-GE09NA-8 MSY-GE12NA-8 MSY-GE15NA-8 MSY-GE18NA-8 ....................................................MXZ-GE-NA-18
MSY-GE24NA ............................................................................................................................................MXZ-GE-NA-19
MUY-GE09NA MUY-GE12NA ...................................................................................................................MXZ-GE-NA-20
MUY-GE15NA-1 ........................................................................................................................................MXZ-GE-NA-21
MUY-GE18NA-1 ........................................................................................................................................MXZ-GE-NA-22
MUY-GE24NA ...........................................................................................................................................MXZ-GE-NA-23
3-5. REFRIGERANT SYSTEM DIAGRAMS ...................................................................................................MXZ-GE-NA-24
MSY-GE09NA-8 MSY-GE12NA-8 MSY-GE15NA-8 MSY-GE18NA-8 ....................................................MXZ-GE-NA-24
MUY-GE09NA ...........................................................................................................................................MXZ-GE-NA-25
MUY-GE12NA MUY-GE15NA-1 ..............................................................................................................MXZ-GE-NA-26
MUY-GE18NA-1 ........................................................................................................................................MXZ-GE-NA-27
MUY-GE24NA ...........................................................................................................................................MXZ-GE-NA-28
3-6. CAPACITY CORRECTION CURVE BY TEMPERATURE .......................................................................MXZ-GE-NA-29
(1) Indoor Unit ...........................................................................................................................................MXZ-GE-NA-29
(2) Outdoor Unit.........................................................................................................................................MXZ-GE-NA-30
3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE .........................................................................MXZ-GE-NA-31
3-8. CAPACITY CORRECTION CURVE BY REFRIGERANT PIPING LENGTH............................................MXZ-GE-NA-32
3-9. CAPACITY CORRECTION TABLE BY REFRIGERANT PIPING LENGTH .............................................MXZ-GE-NA-33
(1) Cooling capacity correction ..................................................................................................................MXZ-GE-NA-33
(2) Maximum refrigerant piping length & maximum height difference .......................................................MXZ-GE-NA-33
(3) M-Series Cooling Correction ................................................................................................................MXZ-GE-NA-34
Due to continuing improvement, above specification may be subject to change without notice.
© 2014 Mitsubishi Electric US, Inc.
M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014)
MSY-GE-1

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric M-SERIES

  • Page 1 (2) Maximum refrigerant piping length & maximum height difference ............MXZ-GE-NA-33 (3) M-Series Cooling Correction ........................MXZ-GE-NA-34 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-1 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 2 3-13. STANDARD OPERATION RANGE ......................MXZ-GE-NA-43 3-14. ACCESSORIES .............................MXZ-GE-NA-44 (1) Indoor Unit ............................MXZ-GE-NA-44 (2) Outdoor Unit ............................MXZ-GE-NA-47 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-2 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 3: Indoor Units

    1. INDOOR UNITS • MSY-GE09NA-8 • MSY-GE12NA-8 • MSY-GE15NA-8 • MSY-GE18NA-8 • MSY-GE24NA Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-3 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 4: Outdoor Units

    2. OUTDOOR UNITS • MUY-GE09NA • MUY-GE12NA • MUY-GE15NA-1 • MUY-GE18NA-1 • MUY-GE24NA Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-4 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 5 • Anti-allergy Enzyme Filter • Limited warranty: five years parts and seven years compressor Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-5 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 6 (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB Rated frequency (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB Maximum frequency Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-6 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 7 (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB Rated frequency (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB Maximum frequency Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-7 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 8: Muy-Ge09Na Muy-Ge12Na

    (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB Rated frequency (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB Maximum frequency Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-8 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 9 (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB Rated frequency (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB Maximum frequency Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-9 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 10 (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 47˚FDB, 43˚FWB Rated frequency (Heating) — Indoor: 70˚FDB, 60˚FWB, Outdoor: 17˚FDB, 15˚FWB Maximum frequency Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-10 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 11: Efficiency Ratings

    10.5 MUY-GE24NA MSY-GE24NA 12.5 Note: Efficiency values based on AHRI 210/240 test method. Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-11 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 12: External Dimensions

    3-2. EXTERNAL DIMENSIONS MSY-GE09NA-8 MSY-GE12NA-8 MSY-GE15NA-8 MSY-GE18NA-8 Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-12 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 13 3-2. EXTERNAL DIMENSIONS MSY-GE24NA Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-13 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 14 3-2. EXTERNAL DIMENSIONS MUY-GE09NA MUY-GE12NA MUY-GE15NA-1 Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-14 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 15 3-2. EXTERNAL DIMENSIONS MUY-GE18NA-1 Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-15 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 16 3-2. EXTERNAL DIMENSIONS MUY-GE24NA Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-16 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 17: Center Of Gravity

    (850) 33-2/16 12-5/8 6-7/16 15-3/4 34-11/16 MUY-GE24NA (840) (320) (163) (400) (330) (880) Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-17 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 18: Electrical Wiring Diagrams

    3-4. ELECTRICAL WIRING DIAGRAMS MSY-GE09NA-8 MSY-GE12NA-8 MSY-GE15NA-8 MSY-GE18NA-8 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-18 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 19 3-4. ELECTRICAL WIRING DIAGRAMS MSY-GE24NA Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-19 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 20 3-4. ELECTRICAL WIRING DIAGRAMS MUY-GE09NA MUY-GE12NA Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-20 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 21 3-4. ELECTRICAL WIRING DIAGRAMS MUY-GE15NA-1 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-21 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 22 3-4. ELECTRICAL WIRING DIAGRAMS MUY-GE18NA-1 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-22 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 23 3-4. ELECTRICAL WIRING DIAGRAMS MUY-GE24NA Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-23 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 24 Refrigerant pipe ø3/8 (with heat insulator) Refrigerant flow in cooling Refrigerant flow in heating Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-24 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 25: Refrigerant System Diagrams

    3-5. REFRIGERANT SYSTEM DIAGRAMS MUY-GE09NA Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-25 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 26 3-5. REFRIGERANT SYSTEM DIAGRAMS MUY-GE12NA MUY-GE15NA-1 Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-26 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 27 3-5. REFRIGERANT SYSTEM DIAGRAMS MUY-GE18NA-1 Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-27 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 28 3-5. REFRIGERANT SYSTEM DIAGRAMS MUY-GE24NA Unit: inch Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-28 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 29: Capacity Correction Curve By Temperature

    SHF at rating condition = 0.80 = 498 CFM Airflow Outdoor intake air DB temperature (°F) Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-29 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 30: Outdoor Unit

    SHF at rating condition = 0.75 Airflow = 634 CFM Outdoor intake air DB temperature (°F) Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-30 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 31 3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE MUY-GE09NA MUY-GE12NA MUY-GE15NA-1 MUY-GE18NA-1 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-31 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 32: Capacity Correction Curve By Refrigerant Piping Length

    DUE TO CONTINUING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS AND DATA ARE STILL UNDER REVIEW Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-32 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 33: Capacity Correction Table By Refrigerant Piping Length

    MUY-GE18NA-1 MUY-GE24NA Indoor unit Additional Piping Max. Height Max. length difference Outdoor unit Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-33 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 34 1.29 1.26 1.22 1.15 1.08 1.02 1.38 1.34 1.32 1.28 1.21 1.14 1.07 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-34 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 35: Charge Calculations

    NOTE: Calculation: X oz. = 2.96/5 oz./ft (Refrigerant piping length (ft) - 33) Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-35 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 36: Air Flow Data

    The coverage should be used only as a general guideline since it varies according to the size of the room and furniture arranged inside the room. Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-36 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 37: Sound Pressure Levels

    2 dB than the displayed level during cooling and heating operation. isplayed level during cooling and heating operation. HEATING(SHi) NC-70 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-37 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) NC-60 © 2014 Mitsubishi Electric US, Inc. NC-50...
  • Page 38 The sound level isplayed level during cooling and heating operation. Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-38 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 39: Noise Criterion Curves

    THRESHOLD OF NC-20 HEARING FOR CONTINUOUS NOISE 1000 2000 4000 8000 BAND CENTER FREQUENCIES,Hz Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-39 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 40 THRESHOLD OF NC-20 HEARING FOR CONTINUOUS NOISE 1000 2000 4000 8000 BAND CENTER FREQUENCIES,Hz Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-40 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 41 THRESHOLD OF NC-20 HEARING FOR CONTINUOUS NOISE 1000 2000 4000 8000 BAND CENTER FREQUENCIES,Hz Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-41 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 42 B(A)) LINE NOTCH SPL(dB(A)) LINE COOLING HEATING NC-70 NC-70 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-42 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) NC-60 NC-60 © 2014 Mitsubishi Electric US, Inc. NC-50 NC-50...
  • Page 43: Standard Operation Range

    Standard temperature — Maximum temperature — Cooling Minimum temperature — Maximum humidity — Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-43 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 44 (requires MAC-333IF-E interface for MSY/Z and MFZ indoor units) Lockdown Bracket for wireless, hand-held, remote RCMKP1CB controllers Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-44 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 45 1/4 x 1/2 x 65' / 1/2" Twin-Tube Insulation MLS141212T-100 1/4 x 1/2 x 100' / 1/2" Twin-Tube Insulation Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-45 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 46 3/8 x 5/8 x 65' / 1/2" Twin-Tube Insulation MPLS385812T-100 3/8 x 5/8 x 100' / 1/2" Twin-Tube Insulation Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-46 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 47 ULTRILITE1 Condensing Unit Mounting Pad 16" x 36" x 3" All Models Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-47 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 48 Due to continuing improvement, above specification may be subject to change without notice. MSY-GE-48 M-Series - MSY/MUY-GE Wall-Mount Systems (July 2014) © 2014 Mitsubishi Electric US, Inc.