Table of Contents

Advertisement

GRUNDFOS DATA BOOKLET
UPM3
1 x 230 V, 50/60 Hz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UPM3S Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Grundfos UPM3S Series

  • Page 1 GRUNDFOS DATA BOOKLET UPM3 1 x 230 V, 50/60 Hz...
  • Page 2: Table Of Contents

    UPM3 1. General information ....4 The AUTO ......32 Selection of control mode.
  • Page 3 UPM3S XX-60 130/180 (N) (GFNHB) ..64 Grundfos’ Product Chemical Compliance UPM3S FLEX AS XX-60 130/180 (N) (GFNHB) . . 65 initiatives ......110 UPM3S AUTO XX-60 130/180 (N).
  • Page 4: General Information

    Consequence of ignoring the warning • Action to avoid the hazard. Notes The symbols and notes below may appear in Grundfos installation and operating instructions, safety instructions and service instructions. Observe these instructions for explosion-proof products. A blue or grey circle with a white graphical symbol indicates that an action must be taken.
  • Page 5: Pump Versions

    PWM A profile CC/MAX Other versions or housings with different dimensions, materials, design or functionality are available on request. Please contact your Grundfos HVAC OEM KAM Abbrevations PWM: Pulse-Width Modulation PWM A/C: Externally controlled via PWM A or C profile...
  • Page 6: Applications

    UPM3 3. Applications In a modern heating, cooling and domestic hot water For some heating generators (e.g. condensing boilers, supply system there are different circuits in which UPM3 heat pumps or district heating) it is important to keep the pumps in different versions can be placed. A return temperature as low as possible.
  • Page 7: Gas- Or Oil-Fired Space And Combination Heaters

    UPM3 Recommended pump type according to application Application Recommended type Gas- or oil-fired space and combination heaters UPM3, UPM3 LIN, UPM3 FLEX AS Solid fuel heaters UPM3 FLEX AS, UPM3 AUTO Heat pumps (brine side) UPM3(K), UPM3 LIN, UPM3(K) FLEX AS Heat production or heat transmission side Heat pumps (heating side) UPM3, UPM3 LIN, UPM3 FLEX AS...
  • Page 8: Micro/Mini Combined Heat And Power Cogeneration

    UPM3 must stand liquid temperatures down to plus 2 °C or Space heating systems lower. For smaller heat pumps with a minimum brine The secondary pump is often a self-controlled stand-alone temperature of +2 °C, we recommend UPM3K with PWM pump, which can be mounted in a heating kit, and signal input.
  • Page 9: Upm3 - Hybrid Variants

    UPM3 UPM3 - HYBRID variants Examples of systems This pump range with operating panel is designed for several purposes: • The internal-controlled variant can be used in heating appliances as stand-alone or replacement pump, for example in heating kits. • The remote-controlled variant can be integrated in boilers and other heating appliances where the speed is changed, corresponding to low-voltage PWM signal...
  • Page 10: Features And Benefits

    UPM3 4. Features and benefits Features • UPM3 LIN is the first Grundfos LIN bus pump for appliance-integrated communication. • Speed-controlled, high-efficiency pump fitted with UPM3K electronically commutated motor (ECM) with permanent-magnet rotor and frequency converter. • The UPM3K pump range is designed for condensing •...
  • Page 11: Upm3F

    When using the UPM3 LIN pump together with the Grundfos GO Balance app and the ALPHA Reader dongle, it is possible to perform hydronic balancing of two- pipe or underfloor-heating systems by using real-time flow measurement from the pump.
  • Page 12: Identification

    UPM3 5. Identification Type key Example: UPM3 SOLAR 15 - 145 130 C A X 9 XXX Code Explanation Designation UPM3 Standard UPM3S Small version with IMM rotor Pump type UPM3L Large version with extended P1 UPMO For ErP upgrade and replacement Code Explanation Designation...
  • Page 13 UPM3 Code Explanation Designation Cast iron CED, 130 mm Cast iron CED, 180 mm N 130 Stainless steel, 130 mm N 150 Stainless steel, 150 mm N 180 Stainless steel, 180 mm GGES2 Cast iron CED, end suction UPM3 GGAOS3 Cast iron CED, AOS3 UPM3 GGMBP3 Cast iron CED, GGMBP3 UPM3...
  • Page 14: Nameplate Options

    < XXW L,avg XXXV ~ XX / XXHz IPXXX TFXXX Min. 0°C P / N : XXXXXXXXX PC: YYWWXXX S / N : XXXXXXXXX Grundfos Holding A/S DK-8850 Bjerringbro Made in XXXXXXX Denmark Nameplate: Grundfos standard Terminal box side Pos.
  • Page 15: Performance Range

    UPM3 6. Performance range [kPa] UPM3L UPM3 UPMO UPM3S 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [m³/h] Q [l/s] Performance range UPM3, UPM3L, UPM3S, UPMO [kPa] 7.5 m Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [l/s]...
  • Page 16 UPM3 [kPa] 14.5 m 10.5 m 7.5 m 2.0 2.2 2.4 2.6 Q [m³/h] Q [l/s] Performance range UPM3 SOLAR, cast iron pump housing...
  • Page 17: External Control Mode And Signals

    UPM3 7. External control mode and signals Control principles PWM interface The UPM3 and UPM3 FLEX pumps are controlled via a The PWM interface consists of an electronic part digital low-voltage pulse-width modulation (PWM) signal connecting the external control signal to the pump. The which means that the speed of rotation depends on the interface translates the external signal into a signal type input signal.
  • Page 18 UPM3 PWM input signal profile A (heating) PWM input signal profile C (solar) At high PWM signal percentages (duty cycles), a At low PWM signal percentages (duty cycles), a hysteresis prevents the pump from starting and stopping if hysteresis prevents the pump from starting and stopping if the input signal fluctuates around the shifting point.
  • Page 19 UPM3 PWM feedback signal (standard) Pos. Description The PWM feedback signal offers pump information like in Slope: 1 % / watt PWM signal bus systems: Saturation at 70 W • current power consumption (accuracy ± 2 % of PWM Slope: 2 % / watt PWM signal signal) Saturation at 140 W •...
  • Page 20 HVAC application. New unique features such as hydronic balancing of heating systems via the Grundfos GO Balance app can be set using LIN bus communication. In order to provide you the best support, Grundfos has divided the LIN bus data points into six specific modules: •...
  • Page 21: Control Modes, Operating Panel And Settings

    UPM3 8. Control modes, operating panel and settings UPM3 UPM3 HYBRID variants UPM3 is externally controlled via a PWM or LIN bus UPM3 HYBRID variants can be controlled both externally signal. and internally. Operating panel Related information PWM interface The operating panel is designed with a single button, one red/green LED and four yellow LEDs.
  • Page 22: Control Modes

    UPM3 Control modes HYBRID control modes and curves Up to five different control modes, each with up to four curves, are available for UPM3 HYBRID variants for different maximum heads. Externally controlled Internally controlled PWM A profile PWM C profile Proportional pressure Constant pressure Constant curve...
  • Page 23 UPM3 Standard range Overview of the standard range for UPM3 UPM3S UPM3S standard range Variant Size XX-40 ● XX-50 ● XX-60 ● XX-60 ● FLEX AS XX-60 ● ● ● AUTO XX-60 ● ● ● ● ● ● HYBRID XX-60 ●...
  • Page 24 UPM3 UPM3L UPM3L standard range Variant Size XX-75 ● XX-75 ● FLEX AS XX-75 ● ● ● AUTO XX-70 ● ● ● ● ● ● HYBRID XX-70 ● ● ● ● ● ● ● ● UPMO UPMO standard range Variant Size XX-50 ●...
  • Page 25 The following factory preset options The pump starts at the factory preset operating mode are available: fixed in the Grundfos software file (GSC). It is overwritten after the first personal setting. A customised factory preset UPM3S UPM3 standard range...
  • Page 26 UPM3 UPMO UPMO standard range Factory preset PWM A PWM C Constant curve Proportional pressure Constant pressure Variant Size XX-50 ● ● UPMO XX-60 ● ● XX-70 ● ● Changing the control mode To set the product, use the button on the operating panel. Every time you press the button, the pump setting is changed.
  • Page 27: Overview Of Operating Panel Control Modes

    UPM3 Overview of operating panel control LED1 LED2 LED3 LED4 LED5 PWM A profile green green yellow yellow yellow modes PWM A curve 1 signal off ● ● All UPM3 HYBRID variants can be controlled with the PWM A button on the operating panel. ●...
  • Page 28 UPM3 UPMO This pump is for internal control with control mode CC or for external PWM signal control with profile A. The pump automatically enables the PWM input-signal control mode by SignalDetect when the signal cable is plugged in. LED1 LED2 LED3 LED4...
  • Page 29: Control Modes With Pump Curves

    UPM3 Control modes with pump curves UPM3 AUTO/HYBRID control modes with pump curves UPM3 FLEX/HYBRID control modes with pump curves...
  • Page 30: Control Mode Explanation

    UPM3 Control mode explanation The duty point of the pump moves up or down on the selected constant curve, depending on the heat demand Proportional pressure in the system. The head (pressure) is reduced at falling heat demand and increased at rising heat demand. The duty point of the pump will move up or down on the selected proportional-pressure curve, depending on the heat demand in the system.
  • Page 31: Pump Control In Heating Systems

    A proportional-pressure-controlled pump The AUTO proportional pressure functionality is well ADAPT reduces the differential pressure as a result of falling heat known from millions of installed Grundfos trade pumps as demand. ALPHA2 or MAGNA. The AUTO setting continually ADAPT...
  • Page 32: The Auto

    UPM3 The AUTO algorithm Example ADAPT This example shows proportional pressure AUTO ADAPT The objective of the AUTO algorithm is to measure ADAPT Note: The constant pressure AUTO function acts and analyse the heating system during operation and ADAPT accordingly just by utilising constant pressure control, and adapt to the current heating pattern.
  • Page 33 UPM3 System analyser New reference setting From the preset reference duty point, the pump will When changing the proportional pressure curve setting to immediately start to analyse the heating pattern. adapt to the requirements of the heating system, AUTO automatically sets a new reference duty The system resistance (K ) is logged and based on this ADAPT...
  • Page 34: Selection Of Control Mode

    UPM3 Selection of control mode The selection of the control mode depends on the system type and the allocation of pressure losses defined by the valve or consumer authority. System type Recommended control mode PWM A profile Heating system with PWM control of the pump. PWM C profile Solar system with PWM control of the pump.
  • Page 35: Technical Description

    UPM3 9. Technical description Exploded view and sectional view Material specification Pos. Component Material EN/DIN Rotor can Stainless steel 1.4401 Pos. Component Material EN/DIN Shaft Ceramics Control box Composite PC-GF10 FR NdFeB or injection- Rotor PCB with SMD moulded ferrite Control electronics components Rotor tube...
  • Page 36: Description Of Components

    EPDM Description of components Stator housing The Grundfos UMP3 pumps are of the canned-rotor type as pump and motor form an integral unit without shaft seal and with only one gasket for sealing and four screws for Stator and windings fastening the stator housing to the pump housing.
  • Page 37 The antimony-free carbon thrust bearing is fitted to the system, the system water lubricates the bearings. This shaft in a flexible EPDM retainer. guarantees the extremely reliable Grundfos ceramic In combination with the bearing plate, the thrust bearing bearing system of wet-running pumps.
  • Page 38 Composite housings are mostly injection-moulded at the Grundfos factory using the tools designed and manufactured by Grundfos. The advantage of composite housings is the flexibility in forming complex housings and other hydraulic parts with low weight and production costs. Composite housings are limited to high-volume parts due to their high investment costs.
  • Page 39 UPM3 Cast-iron electrocoated (CED) in-line Cast-iron electrocoated (CED) OEM housings with threads housings - end-suction with threads or in- line with air outlet CED 15 x 130 mm CED 25 x 130 mm GGES cast-iron, end- GGES cast-iron, end- suction suction Pos.
  • Page 40 UPM3 Pos. Description Connection for manometer or pressure sensor, Ø6 mm, can be opened or closed Connection for manometer or pressure sensor, Ø10 mm, can be opened or closed Inlet copper pipe connection Ø18 mm, fits Fugas brass block Outlet G 3/4 B (ISO 228/1) assembly torque 25 ± 5 Nm Composite in-line housings with threads or clips, with integrated vent, drain and special CIAO2 AC composite,...
  • Page 41 UPM3 Pump housing overview Product Material Type number 15 x 130 98419166 ● 0.7 10 110 ● 15 130 25 x 130 98446965 ● 0.9 10 110 ● 25 130 Cast iron CED PN 25 x 180 98446967 ● 1.0 10 110 ●...
  • Page 42 Composite PA6.6 pumps with threaded flat Expected lifetime of composite PA6.6 sealings housings Since 1989, Grundfos has been manufacturing and selling The expected lifetime of composite PA6.6 housings in pump housings and integrated hydraulic units of polymeric heating applications depends on the liquid temperature composite, primarily PA6.6 with 30 % glass-fibre...
  • Page 43 UPM3 Combination of housings for UPM3S control variants UPM3 standard range UPM3S FLEX AS AUTO HYBRID Housing XX-40 XX-50 XX-60 XX-60 XX-60 XX-60 XX-60 15 x 130 mm ● ● ● ● ● ● ● 25 x 130 mm ● ●...
  • Page 44 UPM3 Combination of housings for UPM3 control variants UPM3 standard range UPM3 FLEX AS AUTO SOLAR HYBRID Housing 15 x 130 mm ● ● ● ● ● ● ● ● ● ● ● ● ● 25 x 130 mm ● ●...
  • Page 45 UPM3 Combination of housings for UPM3L control variants UPM3 standard range UPM3L FLEX AS AUTO HYBRID Housing XX-75 XX-75 XX-75 XX-70 XX-70 15 x 130 mm ● ● ● ● ● 25 x 130 mm ● ● ● ● ● Cast iron CED, PN 10 25 x 180 mm...
  • Page 46: Installation

    UPM3 10. Installation Pumped liquids K-Version/IPX4D: Condensation is acceptable. Storage temperature The pump must not be used for circulation of flammable liquids such as diesel oil and petrol. -40 to +75 °C. Liquid temperature Risk of malfunction or damage when inhibitors or Note: For further lifetime evaluation, the temperature additives are added to the pumped liquids.
  • Page 47: Mechanical Installation

    UPM3 Mechanical installation For mounting dimensions, see the data sheets. • The pump must be installed in the system in such a way that no major amount of air flowing through or Mechanical installation must be carried out by trained gathering in the pump housing affects the pump when persons in accordance with local regulations.
  • Page 48: Insulation

    UPM3 Control box positions The control box gives access to the terminals from the front. If necessary, you can turn the control box in steps of 90 degrees: • 3 o'clock • 6 o'clock • 9 o'clock • 12 o'clock. As standard, the operating panel is in the top position (12 o'clock) when the terminals are in 9 o'clock position.
  • Page 49: Electrical Installation

    The pump requires no external motor protection. High-voltage test • Check that the supply voltage and frequency All Grundfos pumps are tested with 1000 VAC for 1 correspond to the values stated on the nameplate. second according to EN 60335-1 Annex A. •...
  • Page 50: Inrush Current

    NTC option Note: When discussing measurements, it is important to refer to the same method. Since 2007, Grundfos uses the At startup the operating temperature of the pump IEC 61000-3-3 Annex B method for measuring inrush including the NTC resistor is cold. In this situation the current.
  • Page 51 UPM3 Relay and PTC (active - standard for UPM3 HYBRID variants) We recommend that you use this option for pumps that are not in permanent operation and can be interrupted by a relay of the controller of the appliance. VDR3 PTC1 EARTH RL1-B...
  • Page 52: Control Box Connections

    UPM3 Control box connections All UPM3 control boxes have 2 electrical connections on one side: power supply and signal connection. If the signal connection is not needed (e.g. UPM3 AUTO (L)), it can be covered by a blind plug (available as an accessory).
  • Page 53 The cover of the Superseal installation plug can be mounted in two The Grundfos Superseal installation plug can be used to different positions, with the cable relief away from the mount a supply cable locally. The Superseal installation pump or in parallel.
  • Page 54: Overview Of Technical Data

    UPM3 Overview of technical data Feature Specification Nominal supply voltage EU: 1 x 230 V + 10 %/- 15 %, 50/60 Hz Minimum supply voltage 160 VAC (runs with reduced performance) Motor protection The motor is protected by the electronics in the control box and requires no external motor protection. Enclosure class IP44 (standard without drain holes).
  • Page 55: Startup

    UPM3 12. Startup Before you start the UPM3 pump: Mount the pump in the right way. Check that the unions are tightened. Check that the valves are opened. Fill the system and vent it above the pump. Check if the required minimum inlet pressure is available at the pump inlet.
  • Page 56: Service

    UPM3 13. Service Maintaining the product DANGER Electric shock UPM3 pumps are maintenance-free. However, it might be Death or serious personal injury necessary to deblock or to open the pump, for example, if ‐ Before starting any work at the pump, switch off the it is blocked by impurities.
  • Page 57: Fault Finding The Product

    UPM3 14. Fault finding the product Noise in the pump Cause There is air in the pump. Remedy • Let the pump run. The pump vents itself over time. Cause Inlet pressure is too low. Remedy • Increase the system pressure or check the air volume in the expansion tank, if installed. Noise in the system Cause There is air in the system.
  • Page 58: Insufficient Flow

    UPM3 Remedy • Remove impurities. Deblock the pump from the front of the control box with a screwdriver. Cause Pump is defective. Remedy • Replace the pump. Insufficient flow Cause Pump performance is too low. Remedy • Check the external controller and the pump settings. Cause Hydraulic system is closed or system pressure is insufficient.
  • Page 59: Performance Curves And Technical Data

    UPM3 15. Performance curves and technical data Curve conditions UPM3 Product mark max. nom. [W] EEI Part 3 The guidelines below apply to the performance curves: XX-50 GFNKB ≤ 0.20 XX-60 GFNKB ≤ 0.20 • Test liquid: airless water. XX-70 GFNKB ≤...
  • Page 60: Accessories

    UPM3 16. Accessories Power supply Superseal Product Length Product Picture Product description Pcs/box number [mm] number Power supply cable Superseal 1000 98460260 59200566 Power supply cable Superseal 2000 98373382 59200567 Power supply cable Superseal 4000 98460271 59200568 Power supply Superseal overmoulded 1000 98460258 59200569...
  • Page 61: Gaskets

    Both insulation shells are easy to fit around the ALPHA Reader is the receiver and transmitter of pump pump. performance data. The unit uses a CR2032 lithium battery. The unit is together with the Grundfos GO Description Product number Balance app used for balancing heating systems.
  • Page 62: Data Sheets

    UPM3 17. Data sheets UPM3S XX-40 130/180 (N) (GFNHB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 12 W L,avg Dimensions Pump settings 1 factory preset Electrical data, 1 x 230 V, 50 Hz Speed Min.
  • Page 63: Upm3S Xx-50 130/180 (N) (Gfnhb)

    UPM3 UPM3S XX-50 130/180 (N) (GFNHB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 16 W L,avg Dimensions Pump settings 1 factory preset Electrical data, 1 x 230 V, 50 Hz Speed Min. 0.04 Max. 0.36 Technical data System...
  • Page 64: Upm3S Xx-60 130/180 (N) (Gfnhb)

    UPM3 UPM3S XX-60 130/180 (N) (GFNHB) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q [m³/h] Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q [m³/h] EEI ≤...
  • Page 65: Upm3S Flex As Xx-60 130/180 (N) (Gfnhb)

    UPM3 UPM3S FLEX AS XX-60 130/180 (N) (GFNHB) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q [m³/h] Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q [m³/h] EEI ≤...
  • Page 66: Upm3S Auto Xx-60 130/180 (N)

    UPM3 UPM3S AUTO XX-60 130/180 (N) [kPa] Line type Description ________ Constant curve Q [m³/h] _ _ _ _ _ _ Proportional pressure Q [l/s] __ . __ . __ . __ Constant pressure Q [m³/h] Q [l/s] EEI ≤ 0.20 Part 3 ≤...
  • Page 67: Upm3(K) Xx-50 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) XX-50 130/180 (N) (GFNKB) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q [m³/h] Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q [m³/h] EEI: ≤...
  • Page 68: Upm3(K) Xx-60 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) XX-60 130/180 (N) (GFNKB) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 Q [m³/h] Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 Q [m³/h] EEI: ≤...
  • Page 69: Upm3(K) Xx-70 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) XX-70 130/180 (N) (GFNKB) [kPa] Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [m³/h] EEI: ≤...
  • Page 70: Upm3(K) Xx-75 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) XX-75 130/180 (N) (GFNKB) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [m³/h] Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [m³/h] EEI: ≤...
  • Page 71: Upm3(K) Flex As Xx-50 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) FLEX AS XX-50 130/180 (N) (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 16 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 18 W Curve 2 25 W Curve 3 33 W Pump settings...
  • Page 72: Upm3(K) Flex As Xx-70 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) FLEX AS XX-70 130/180 (N) (GFNKB) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 Q [m³/h] Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 Q [m³/h] EEI ≤...
  • Page 73: Upm3(K) Flex As Xx-75 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) FLEX AS XX-75 130/180 (N) (GFNKB) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 Q [m³/h] Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 Q [m³/h] EEI ≤...
  • Page 74: Upm3(K) Flex As 15-75 Cil3 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CIL3 (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 75: Upm3(K) Flex As 15-75 Gges3 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 GGES3 (GFNKB) EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings PWM A PWM C Electrical data, 1 x 230 V, 50 Hz...
  • Page 76: Upm3(K) Flex As 15-75 Ggmbp3 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 GGMBP3 (GFNKB) [kPa] 2.6 2.8 3.0 3.2 3.4 Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Q [l/s] Q [l/s] 2.6 2.8 3.0 3.2 3.4 Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 EEI ≤...
  • Page 77: Upm3(K) Flex As 15-75 Ggbp3 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 GGBP3 (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 78: Upm3(K) Flex As 15-75 Ggaos3 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 GGAOS3 (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Setting Max. head Max. P 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 79: Upm3(K) Flex As 15-75 Ciao2 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CIAO2 (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 80: Upm3(K) Flex As 15-75 Ciao2 Ac (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CIAO2 AC (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W...
  • Page 81: Upm3(K) Flex As 15-75 Ces3 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CES3 (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 82: Upm3(K) Flex As 15-75 Cacao (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CACAO (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 83: Upm3(K) Flex As 15-75 Cesao1 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CESAO1 (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Setting Max. head Max. P 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 84: Upm3(K) Flex As 15-75 Cesao2 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CESAO2 (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Setting Max. head Max. P 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 85: Upm3(K) Flex As 15-75 Cesao4 (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CESAO4 (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 86: Upm3(K) Flex As 15-75 Aokr (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 AOKR (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 87: Upm3(K) Flex As 15-75 Caod (Gfnkb)

    UPM3 UPM3(K) FLEX AS 15-75 CAOD (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 28 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 7.5 m 60 W Pump settings...
  • Page 88: Upm3(K) Auto Xx-50 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) AUTO XX-50 130/180 (N) (GFNKB) [kPa] Line type Description ________ Constant curve 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q [m³/h] _ _ _ _ _ _ Proportional pressure Q [l/s] __ .
  • Page 89: Upm3(K) Auto Xx-70 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) AUTO XX-70 130/180 (N) (GFNKB) [kPa] Line type Description ________ Constant curve 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [m³/h] _ _ _ _ _ _ Proportional pressure Q [l/s] __ .
  • Page 90: Upm3(K) Hybrid Xx-50 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) HYBRID XX-50 130/180 (N) (GFNKB) [kPa] Line type Description ________ Constant curve 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Q [m³/h] _ _ _ _ _ _ Proportional pressure Q [l/s] __ .
  • Page 91: Upm3(K) Hybrid Xx-70 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) HYBRID XX-70 130/180 (N) (GFNKB) [kPa] Line type Description ________ Constant curve 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [m³/h] _ _ _ _ _ _ Proportional pressure Q [l/s] __ .
  • Page 92: Upm3(K) Dhw Xx-20 130/180 N (Gfnkb)

    UPM3 UPM3(K) DHW XX-20 130/180 N (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 7 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 Curve 2 1.5 m Curve 3 11 W Pump settings PWM A PWM C...
  • Page 93: Upm3(K) Dhw Xx-50 130/180 N (Gfnkb)

    UPM3 UPM3(K) DHW XX-50 130/180 N (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 16 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 18 W Curve 2 25 W Curve 3 33 W Pump settings PWM A...
  • Page 94: Upm3(K) Dhw Xx-70 130/180 N (Gfnkb)

    UPM3 UPM3(K) DHW XX-70 130/180 N (GFNKB) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 Q [m³/h] Q [l/s] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 Q [m³/h] EEI ≤...
  • Page 95: Upm3(K) Dhw 15-20 Cil3 Pps (Gfnkb)

    UPM3 UPM3(K) DHW 15-20 CIL3 PPS (GFNKB) [kPa] Q [m³/h] 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 7 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 Curve 2 1.5 m...
  • Page 96: Upm3(K) Dhw 15-50 Cil3 Pps (Gfnkb)

    UPM3 UPM3(K) DHW 15-50 CIL3 PPS (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 16 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 18 W Curve 2 25 W Curve 3 33 W Pump settings PWM A...
  • Page 97: Upm3(K) Dhw 15-70 Cil3 Pps (Gfnkb)

    UPM3 UPM3(K) DHW 15-70 CIL3 PPS (GFNKB) [kPa] Q [m³/h] Q [l/s] Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 23 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 33 W Curve 2 39 W Curve 3 52 W Pump settings PWM A...
  • Page 98: Upm3(K) Solar Xx-75 130/180 (N) (Gfnkb)

    UPM3 UPM3(K) SOLAR XX-75 130/180 (N) (GFNKB) [kPa] 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 Q [m³/h] Q [l/s] 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 Q [m³/h] EEI ≤...
  • Page 99 UPM3 UPM3(K) SOLAR XX-105 130/180 (GFNKB) [kPa] 1.6 1.8 Q [m³/h] Q [l/s] 1.2 1.4 1.6 1.8 2.4 2.6 Q [m³/h] EEI ≤ 0.20 Part 3 ≤ 22 W L,avg Dimensions Setting Max. head Max. P 1 nom Curve 1 6.5 m 39 W Curve 2...
  • Page 100: Upm3(K) Solar Xx-145 130/180 (Gfnkb)

    UPM3 UPM3(K) SOLAR XX-145 130/180 (GFNKB) [kPa] Q [m³/h] 1.2 1.4 2.4 2.6 Q [l/s] Q [m³/h] 1.2 1.4 2.4 2.6 EEI ≤ 0.20 Part 3 ≤ 25 W L,avg Dimensions Max. head Max. P Setting 1 nom Curve 1 8.5 m 45 W Curve 2...
  • Page 101: Upm3L Xx-75 130/180 (N) (Gfnkc)

    UPM3 UPM3L XX-75 130/180 (N) (GFNKC) [kPa] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 Q [m³/h] Q [l/s] Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 EEI ≤...
  • Page 102: Upm3L Flex As Xx-75 130/180 (N) (Gfnkc)

    UPM3 UPM3L FLEX AS XX-75 130/180 (N) (GFNKC) [kPa ] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 Q [m³/h] Q [l/s] Q [m³/h] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 EEI ≤...
  • Page 103: Upm3L Auto Xx-70 130/180 (N)

    UPM3 UPM3L AUTO XX-70 130/180 (N) [kPa] Line type Description ________ Constant curve Q [m³/h] _ _ _ _ _ _ Proportional pressure Q [l/s] __ . __ . __ . __ Constant pressure Q [m³/h] Q [l/s] EEI ≤ 0.20 Part 3 ≤...
  • Page 104: Upm3L Hybrid Xx-70 130/180 (N)

    UPM3 UPM3L HYBRID XX-70 130/180 (N) [kPa] Line type Description ________ Constant curve Q [m³/h] _ _ _ _ _ _ Proportional pressure Q [l/s] __ . __ . __ . __ Constant pressure Q [m³/h] Q [l/s] EEI ≤ 0.20 Part 3 ≤...
  • Page 105: Upmo Xx-50 130/180, Upmo 60 Ph (Gfnkb)

    180 90 72 47 25.5 102 127.5 R1 / G 1 1/2 2.0 xx temperature needed Liquid Approval and 60 PH 90 72 47 75.5 0.97 xx 2-110 °C (TF110) VDE, CE temperature marking For PWM speed curves contact Grundfos HVAC OEM.
  • Page 106: Upmo Xx-60 130/180, Upmo 60 Ph (Gfnkb)

    180 90 72 47 25.5 102 127.5 R1 / G 1 1/2 temperature needed Liquid Approval and 60 PH 90 72 47 75.5 0.97 2-110 °C (TF110) VDE, CE temperature marking For PWM speed curves contact Grundfos HVAC OEM.
  • Page 107: Upmo Xx-70 130/180, Upmo 60 Ph (Gfnkc)

    180 90 72 47 25.5 102 127.5 R1 / G 1 1/2 2.0 xx temperature needed Liquid Approval and 60 PH 90 72 47 75.5 0.97 xx 2-110 °C (TF110) VDE, CE temperature marking For PWM speed curves contact Grundfos HVAC OEM.
  • Page 108: Approvals And Certificates

    UPM3 18. Approvals and Certificates EU declaration of conformity We, Grundfos, declare under our sole responsibility that the products marked with GFNHB, GFNKB, GFNKC, GFNJB, GFNJC, GFNJD, GFNJF and GFNJG, to which the declaration below relates, are in conformity with the...
  • Page 109: Vde Certificate

    Grundfos Product Chemical Compliance declaration concerning the non-use of certain chemical substances GRUNDFOS Holding A/S and its subsidiaries are aware of their responsibilities and are committed not to use hazardous substances in their products. Grundfos products manufactured and placed on the market within the European Union (EU) and the European Economic Area (EEA) comply with the following EU chemical legislation: •...
  • Page 110: Grundfos' Product Chemical Compliance Initiatives

    Grundfos Focus List, which bans or restricts the use of certain chemical substances in Grundfos products, Grundfos production processes and at Grundfos facilities. The process set-out in Grundfos is to phase out the use of the substances of very high concern (SVHC) from the REACH Candidate List (www.echa.europa.eu/web/guest/candidate-list-table).
  • Page 111 UPM3 Grundfos may – on request – mark HVAC OEM circulators with the WEEE crossed out wheelie bin, but this does not imply Grundfos taking any WEEE obligations.
  • Page 112: Abbreviations

    UPM3 19. Abbreviations Abbreviation Explanation Abbreviation Explanation Degree of German water hardness, replaced by the SI Weighted average power input of a pump on a °dH P L, avg unit mmol/l. Conversion: 1 °dh = 0.1783 mmol/l reference profile reg. EN 16297 Alternating current Power consumption (power supply input) Material safety approval required for materials and...
  • Page 113 UPM3...
  • Page 114 2941 Brighton Road Fax: +36-23 511 111 N-1011 Oslo Turkey Oakville, Ontario Tel.: +47-22 90 47 00 GRUNDFOS POMPA San. ve Tic. Ltd. Sti. India L6H 6C9 Fax: +47-22 32 21 50 Gebze Organize Sanayi Bölgesi GRUNDFOS Pumps India Private Limited Tel.: +1-905 829 9533...
  • Page 115 Tel.: +1 913 227 3400 Fax: +1 913 227 3500 Uzbekistan Grundfos Tashkent, Uzbekistan The Representative Office of Grundfos Kazakhstan in Uzbekistan 38a, Oybek street, Tashkent Tel.: (+998) 71 150 3290 / 71 150 3291 Fax: (+998) 71 150 3292...
  • Page 116 98644852 07.2020 ECM: 1290263...

This manual is also suitable for:

Upm3 seriesUpm3l seriesUpmo series

Table of Contents

Save PDF