No.
Function
1
Setting the duration for the door opener
– When activated, the door can be opened during the period from 1 second to 10 seconds, depending on
the setting.
2
Setting the duration of the lighting
– When activated, the lighting remains on for 1 second to 5 minutes, depending on the setting.
3
Status LED
4
Floating output of door opener
5
Power supply of door opener
6
• Connection for the outdoor station
• When using several outdoor stations: connection for the external bus
7
• Connection for the indoor station
• When using several indoor stations: connection for the internal bus
8
Floating output for the light
9
Power supply
Pos: 20 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
| 0073-1-7523
The status LED lights up permanently
The status LED flashes slowly
The status LED flashes fast
= the device is operating
= the device is operating
= there is an error