Pumping station for waste water, floor-standing or underground (36 pages)
Summary of Contents for Saniflo Sanipack
Page 1
1. Description Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan. The Sanipack will pump away the waste from a WC, washbasin and shower. Sanipack is for domestic use.
Page 2
3. Dimensions and overall measurements 4. Performance Curve & Height and Length of the discharge pipe EN 12050-3 Flow Rate - litre/min max 10m max 20m max 30m max 40m max 50m...
5. Installation Sanipack is designed to fi t behind panelling, and should be installed by a qualifi ed person. WARNING: The unit must be connected to a WC pan with a horizontal outlet spigot The Sanipack has fastenings preventing it turning or from moving.
Page 4
6. Connection to a WC ø 100 100mm The fl exible sleeve is designed to fi t onto the 100mm WC pan spigot. Grease the pan spigot with silicon lubricant or liquid soap. Align the fl exible sleeve with the pan spigot. Pull the fl exible sleeve over the pan spigot using the two ears projecting from the sleeve.
Page 5
9. Connection of the discharge pipework Note: Diagrams 5,6,7 & 8 show the Saniplus and not the Sanipack as an example only. ø 22 ø 28 ø 32 Vertical before horizontal Air Admittance Valve If required, cut off the end of the elbow (F) in order to accommodate the appropriate discharge pipe.
Page 6
It is not suitable for heavy commercial/industrial applications. Warning: If the Sanipack runs with very hot/boiling water for a prolonged time, the thermal cut out device will stop the motor from operating. In this case, it will take approximately hour for the motor and water to cool down, after which it will automatically re-activate. Do not use Sanipack with a shower discharging at more than 15 litres per minute.
Page 7
14. Care of your unit In order to remove scale and clean the macerator and the bowl, use a household descalent (like SANIFLO descaler). As a general rule, household disinfectants and bleaches designed for a normal WC are suitable for use with a Sanifl o unit.
Page 8
Ease the fl exible connector off the WC pan spigot and slide the Sanipack out from behind the panel. Note: To ease replacement of the lid onto the Sanipack case, lubricate the rubber seal with liquid soap before replacing. Do not reconnect the electrical supply until the re-installation of the unit is complete.