Electrical system
Still no spark?
Dismantle the fan housing cover with at-
tached starter.
502 50 18-01
Check other cables and connections.
Still no spark?
Check the air gap.
0.3
502 51 34-02
Adjust the air gap.
502 50 19-01
Still no spark?
Dismantle the fan housing cover with at-
tached starter.
Remove the 3 screws, lift off the plate (A)
and then the cover.
Check other cables and connections for
poor contacts (dirt, corrosion, cable brea-
kage and damaged insulation).
Make sure that the cables are correctly
drawn.
See chapter 3 "Throttle".
TIP!
Use an Ohmmeter in order to easily check
if cable breakage has occurred, due to
pinching, for example.
Still no spark?
Check the air gap between the fl y wheel
magnet and the ignition module.
The gap should be 0.3 mm.
Use air gap gauge 502 51 34-02.
Adjust the air gap to the right measure-
ment.
Loosen the screws.
Insert the feeler gauge and press the
ignition module against the fl ywheel.
Tighten the screws and check the air
gap once again.
If there is still no spark, the ignition system
should be replaced.