Lyric Controller Programming Guide
Testing the System (Continued)
Programming Field
RF Sniffer Test
Go-No-Go Test
Diagnostics
Zone Discovery
Install Cell
System Information System Information is displayed. Select OK to return to the previous screen.
Install Backup
Battery
NOTES: (1)
Button-type 5800 series devices do not automatically send check-in signals and must physically be
activated to clear the display.
(2) When one button of a button type, supervised or unsupervised RF transmitter is activated, all zones assigned to
other buttons on that transmitter are cleared. This also applies to transmitters that have multiple loops (zones).
(3) Any transmitter that is not "entered" will not turn off its zone number.
(4) For SIA installations, the following devices may be used as specified for panic (24-hour) alarm response:
• wireless keys which have two-button panic pairs available, on which only the two-button panic pairs may be
programmed for any 24-hour alarm response
• wireless keypads that have a two-second delay on the special function keys, or two-button panic pairs
• built-in keypad panic key
(5) Go-No-Go Test will be automatically terminated after 3-1/2 to 4 hours if it is not manually terminated. This
ensures that fire and panic zones will not remain disabled. RF Sniffer Test Mode does not automatically expire
and must be exited manually to return to normal operation. During the final 5 minutes the system will emit
double beeps indicating that the end of Test mode is nearing.
Rebooting the System
The Reboot function allows you to restart the system if required. To reboot the system perform the following:
Step
1.
With the System in the Installer Programming mode, select the "Test" button and then select the
"Diagnostics" button.
2.
The system advances to the next screen. Select the "Reboot" button.
3.
A confirmation screen appears. Select "Yes". The system will restart.
NOTE: If the controller has been defaulted or is not associated with AlarmNet 360, the WiFi
enrollment screen will be displayed when the boot-up is complete.
NOTE: After the reboot sequence is complete a "Walk Test" should be performed to verify that all transmitters are
operational in the system.
NOTE: If the communicator is in the process of sending a report to the Central Station,
the system will not enter the RF Sniffer Mode. Wait a few minutes and try again.
1. The system displays all programmed zone numbers and zone descriptors which have
a non-zero Zone Type. Fault each transmitter in turn, causing each one to send a
signal. As the system receives a signal from each of the transmitters, the zone number
of that transmitter disappears from the display. The transmitters may be checked
upon installation, or in an installed system.
2. When all transmitters have been checked, Exit RF Sniffer Test mode by depressing
the Home key and entering the Installer Code or a User Code.
Once the transmitters have been enrolled and placed in their desired locations, and the
approximate length of wire to be run to sensors is connected to the transmitter screw
terminals (if used), fault each transmitter.
1. The keypad beeps three times indicating signal reception, displays the appropriate
zone number and announced the zone description.
2. If the keypad does not beep, reorient or move the transmitter to another location.
Usually a few inches in either direction is all that is required.
3. If each transmitter produces the proper keypad response when faulted, they can be
permanently mounted according to their respective instructions.
3. Exit Go-No-Go Test mode by depressing the Home key and entering the Installer
Code or a User Code.
Provides access to the Reboot Feature. Refer to the paragraph in this section for
additional information regarding this feature.
1. The "Zone Discovery" button is highlighted indicating that the mode is active.
2. Exit Zone Discovery Mode by depressing the Home key and entering the Installer or a
User Code. If you do not exit Zone Discovery Mode manually, the system will
automatically exit Zone Discovery Mode in approximately 1-4 minutes dependent
upon the number of zones that are programmed. The system beeps once and returns
to the home screen.
User feature that allow the Master User to install or replace a Communications Module.
Refer to the User Guide (p/n 800-18078) for additional information.
User feature that allow the Master User to replace the backup battery. Refer to the User
Guide (p/n 800-18078) for additional information.
Function and Action
Action
- 30 -
Need help?
Do you have a question about the Lyric and is the answer not in the manual?
Questions and answers