91.1
SPN 2795/FMI 9
[a] If the resistance is greater than 5 Ω, repair the open between pin 4 of the turbo actuator
connector and pin 75 of the MCM 120–pin connector. Refer to section 91.1.1.1.
[b] If the resistance is less than 5 Ω, replace the turbo actuator. Refer to section 91.1.1.1.
91.1.1.1
Verify Repairs
Verify repairs as follows:
1. Turn ignition OFF.
2. Reconnect any electrical connections that were disconnected to perform the diagnosis.
3. Clear codes with DDDL 7.0 or latest version.
4. Start and bring engine up to operating temperature (over 140°F/60°C).
5. Verify operation is satisfactory and no warning lamps illuminate. If warning lamps
illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel
Customer Support Center at 313–592–5800.
91-4
6SE568
Copyright © PRELIMINARY 2007 DETROIT DIESEL CORPORATION
(Rev. ) All information subject to change without notice.
Need help?
Do you have a question about the MBE 4000 DDEC VI and is the answer not in the manual?
Questions and answers