Chapter 3 Appendix
(2)
Error reporting via beep
Even if an error is detected by POST, the error message may be unable to be displayed in the display. In this
case, the server beeps to report that an error has occurred.
For example, the beep code 1-3-3-1 indicates 1 beep, a pause, 3 beeps, a pause, 3 beeps, a pause, and 1 beep,
which means that an error occurred while checking the memory capacity.
The table below shows the beep code, cause, and solution.
Beep Code
1-3-3-1
1-5-2-1
1-1
1
3
4
7
8
130
Cause
No memory module is installed.
Or, failed to detect memory.
The processor is not installed.
Or, failed to detect processor.
No graphics controller could be detected.
POST detected an error.
Failed to read BIOS data.
Or, failed to execute BIOS.
Failed to initialize the BIOS executable
module.
Failed to reset the system.
An error was detected when allocating the
PCI resources.
Express5800/E120d-1 Maintenance Guide
Solution
Make sure that the DIMMs are correctly
inserted.
If the same error is detected repeatedly, ask
your sales representative to replace DIMM or
motherboard.
Make sure that the processor is correctly
mounted. If the same error is detected
repeatedly, ask your sales representative to
replace DIMM or motherboard.
Contact your sales representative to replace
motherboard.
Remove all the installed PCI boards to PCI
slots, and then reboot the server.
If the same error is detected repeatedly, contact
your sales representative.