F. Air Cleaner

Air Cleaner Element

Clean --- every 250 hours
Replace --- after cleaning 6 times or after one year
1. Stop the engine before servicing element (1).
2. Remove clamps (2) (2 places) on cover (3).
3. Remove element (1).
4. Tap element (1) with the palm of your hand. Never tap
element (1) on a hard surface.
d
WARNING: Use reduced compressed air pressure (Less
than 0.69 MPa (7 kgf/cm
guard against flying chips, and wear personal
protection equipment including goggles or safety
glasses.
IMPORTANT: To clean element (1), avoid giving shocks or
striking element (1) with other objects.
5. Clean element (1) by blowing compressed air (less than
0.69 MPa (7 kgf/cm
filter element. After cleaning, be sure to check element
(1) for any damage. If any damage is found, replace the
element with a new one.
6. When installing cover (3), position cover (3) so that valve
(4) faces downward. Tighten clamps (2).
)). Clear area of bystanders,
2
)) outward from the inside of the
2
MAINTENANCE
3
7-60
1
4
2
2
ZX17U-5A
2
ZX26U-5A
5
M555-07-023
3
4
MABA-07-033
4
MABA-07-034