Sony SIR-1000W Instruction Manual page 95

High speed digital data recorder, channel expansion unit
Table of Contents

Advertisement

Command
FMT : (SIR-1000i only)
Command format
IDS :
Command format
INP :
(SIR-1000/SIR-1000i only)
Command format
LCH : (SIR-1000W only)
Command format
MEM :
Command format
MOD :
Command format
Tape formatting
FMT : <1><2><3><4>/[ ]
<1>: 0 = RSV, 1 = Formatting start
<2><3><4>: ID number at formatting (001 to 999)
Note
This command logically erases all pre-recorded data.
Related command: FMT?
ID increment
IDS : <1>
<1>: 0 = RSV, 1 = ID increment
The recorder ID is incremented each time the IDS:1 command is issued.
Related command: IDS?
Input format setting
INP : <1><2>...<17>/[ ]
<1>: Channel expansion unit ID number
0 = Recorder
1 = Channel expansion unit 1
2 = Channel expansion unit 2
3 = Channel expansion unit 3
4 = Channel expansion unit 4
5 = Channel expansion unit 5
6 = Channel expansion unit 6
7 = Channel expansion unit 7
<2>: Input format for CH1
0 = DIRECT
1 = SENSOR
<3>: Input format for CH2
.
.
.
<17>: Input format for CH16
Related command: INP?
LSB digital channel setting
LCH : <1>/[ ]
<1>: 0 = OFF
1 = 1ch
2 = 2ch
3 = 4ch
Note
Related command: LCH?
Annotation character string setting
MEM : <1><2>...<96>/[ ]
<1><2>...<96>: ASCII characters (20h to FFhex) up to maximum 96 characters
Ex.) MEM:MEASUREMENT-1 — (Annotation character string "MEASUREMENT-1" set.)
Related command: MEM?
Tape transport mode setting
MOD : <1>/[ ]
<1>: 0 = STOP, 1 = FWD, 2 = E-E, 3 = REC, 4 = FWD-PAUSE, 5 = REC-PAUSE, 6 = FF,
7 = RSV, 8 = REW, 9 = RSV, A = EJECT
Ex.) MOD:1 — FWD mode
Related command: MOD?