Trikdis FLEXi SP3 Installation And Programming Manual

Trikdis FLEXi SP3 Installation And Programming Manual

Security control panel
Hide thumbs Also See for FLEXi SP3:
Table of Contents

Advertisement

Security control panel
"FLEXi" SP3
Installation and programming manual
July, 2020
www.trikdis.com
UAB Trikdis Draugystės g. 17, LT-51229 Kaunas, Lithuania +370 37 408 040
info@trikdis.lt

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLEXi SP3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Trikdis FLEXi SP3

  • Page 1 Security control panel “FLEXi” SP3 Installation and programming manual July, 2020 www.trikdis.com UAB Trikdis Draugystės g. 17, LT-51229 Kaunas, Lithuania +370 37 408 040 info@trikdis.lt...
  • Page 2: Table Of Contents

    ................................36 IRELESS WINDOW 5.6.1 Linking the wireless equipment transceiver RF-SH to the „FLEXi“ SP3 control panel ..........36 5.6.2 Linking wireless (FW2 series) sensors ......................... 36 5.6.3 Linking a wireless (FW2 series) remote controller ...................... 37 www.trikdis.com July 2020...
  • Page 3 WINDOW 5.9 “S ” ................................45 ENSORS WINDOW 5.10 “S ” ..............................46 YSTEM EVENTS WINDOW 5.11 “E ” ................................. 47 VENTS LOG WINDOW 5.12 R ..............................47 ESTORE DEFAULT SETTINGS 5.13 U ................................47 PDATING FIRMWARE www.trikdis.com July 2020...
  • Page 4  robbery, fire of the premises or any other losses suffered by the panel‘s buyer or user, and shall not compensate the panel‘s buyer or user for any property or non-property damages suffered from these events. www.trikdis.com July 2020...
  • Page 5 3mm. The safety switch must be installed in a location known to the specialists servicing the control panel. To disconnect the control panel from the power network: from the AC network – switch off the automatic safety switch; from the battery – disconnect the terminals. www.trikdis.com July 2020...
  • Page 6: Description

    2G/4G modem.  Additional modules to send reports via Ethernet or VHF/UHF radio waves with chosen priority.  Any CMS can receive reports, as long as they have TRIKDIS software/IP receiver other manufacturer’s IP receiver supporting SIA DC-09 IP protocol.
  • Page 7: Technical Specifications

    2,4 GHz, 802.11 b/g/n, WPA, WPA2, WPA mixed WiFi network configuration type DHCP or manual SIM card 1, NANO size GSM/GPRS modem frequencies 850 / 900 / 1800 / 1900 MHz 4G modem frequencies „FLEXi” SP3_14E B1/B3/B7/B8/B20/B28 „FLEXi” SP3_24E www.trikdis.com July 2020...
  • Page 8 Paradox K32+ LED Paradox K35 Paradox TM50 Paradox TM70 Crow CR16 Crow CR-LCD Max. number of RFID readers (Wiegand 26/34) 1-Wire data bus length [1 WIRE] Up to 30 m Compatible temperature sensors Maxim®/Dallas® DS18S20, DS18B20; AM2301 series www.trikdis.com July 2020...
  • Page 9: List Of Compatible Modules

    Min 50 mA, max 150 mA iO-WL wireless expander module Max 200 mA RF-SH transceiver for wireless sensors Max 100 mA E485 Ethernet communicator Min 50 mA, max 150 mA TM17 iButton key reader Max 50 mA www.trikdis.com July 2020...
  • Page 10: Purpose Of External Terminals

    Keypad data bus A 485 Terminal A of RS485 data bus B 485 Terminal B of RS485 data bus IO1 – IO9 Input/output terminals (default setting – input) IO10 Input/output terminal (default setting – PGM output, Fire Sensor Reset) www.trikdis.com July 2020...
  • Page 11: Led Indication Of Operation

    12 V battery. If the battery’s voltage falls to 11,5 V, a Low Battery event report will be generated. The battery will be disconnected if the voltage falls bellow 9,5 V. If AC network voltage is restored, an AC www.trikdis.com July 2020...
  • Page 12: Control Panel Kits

    Planning the system: Sketch a plan of the premises and mark the areas where the metal housing with the control panel, keypad (-s), signallers,  equipment automatically or remotely controlled by the control panel will be installed. www.trikdis.com July 2020...
  • Page 13: Installing The Control Panel Into The Mounting Housing

    EN 60950 and EN 50131 standards. Plastic spacers. Dimensions of the „FLEXi“ SP3 board The picture below shows the dimensions of the board and its mounting holes (in millimeters), and also the locations of the holes. www.trikdis.com July 2020...
  • Page 14: Order Of Connecting Devices

    Enable report sending. Default settings enable the event report sending function for all events. If any event occurs, its report will be sent to the set recipients using the set channels. See chapter 5.10 ““System events” window” on how to disable reporting of chosen events. www.trikdis.com July 2020...
  • Page 15: Connecting Sensors

    (NO, NC, EOL, EOL_T, ATZ, ATZ_T); sensitivity to temporary circuit events; zone function (Delay, Instant, Instant Stay, Interior, Interior Stay, Fire, Keyswitch, 24_hour, Silent, Silent 24h), see chapter 5.7 ““Zones” window”. Schematics for connecting sensors. www.trikdis.com July 2020...
  • Page 16: Connecting Smoke Detectors

    To connect a four-wire smoke detector circuit to a selected PGM output, the Fire Sensor Reset function must be assigned to the output (see chapter 5.8 ““PGM” window””). Schematic for connecting four-wire smoke detectors. Schematic for connecting two-wire smoke detectors. www.trikdis.com July 2020...
  • Page 17: Schematic For Connecting A Siren

    Up to 8 devices can be connected to the keypad data bus. The type of the connected keypad must be specified using TrikdisConfig software (see chapter 5.5 ““Modules” window”). The control panel will automatically recognize and link the connected devices. www.trikdis.com July 2020...
  • Page 18 Security control panel „FLEXi“ SP3 Up to 2 RFID readers can be connected to the control panel. If 2 RFID readers are connected to the control panel, no keypads can be connected. www.trikdis.com July 2020...
  • Page 19: Schematics For Connecting Tm17, Cz-Dallas Readers

    30 m: The TM17 reader connects to the „FLEXi“ SP3 using the RS485 data bus. The length of the wires connecting to the RS485 data bus can be up to 100 m. www.trikdis.com July 2020...
  • Page 20: Schematic For Connecting A Temperature Sensor

    5.5 ““Modules” window”. If the security control panel „FLEXi“ SP3 needs to have more inputs IN or outputs OUT, connect a wired or wireless TRIKDIS iO series input and output expander. The „FLEXi“ SP3 ’s configuration for expander modules is described in chapter 5.5 ““Modules”...
  • Page 21: Schematics For Connecting I Oseries Expander Modules 3.12 Schematics For Connecting Rf Transmitter T16

    Security control panel „FLEXi“ SP3 RF transmitter T16 used for transmitting security control panel event messages via TRIKDIS radio networks. The transmitter can send its own event messages and event messages received from security control panels to the CMS (central monitoring station) with the possibility to forward to the end user.
  • Page 22: Arming / Disarming The System Using Protegus

    Structue of SMS message: Command Password Data space space The control panel’s default SMS password is 123456. For safety reasons we recommend changing it to something only You know and not forgetting Your password! SMS command list www.trikdis.com July 2020...
  • Page 23 Connect to Protegus cloud service. E.g.: CONNECT 123456 PROTEGUS=ON Protegus=OFF Disconnect from Protegus cloud service. E.g.: CONNECT 123456 PROTEGUS=OFF Code=123456 Protegus cloud service code. E.g.: CONNECT 123456 CODE=123456 IP=0.0.0.0:8000 Specify the main server’s connection channel’s TCP IP and Port. E.g.: CONNECT 123456 IP=0.0.0.0:8000 www.trikdis.com July 2020...
  • Page 24: Control Via Phone Call

    An audio signal accompanies the beginning and end of the audio file recording. Audio file recording time 15 sec. An audio signal accompanies the end of audio playback.Recording is complete when you hear a beep. Other actions can only be taken when the beep is heard. www.trikdis.com July 2020...
  • Page 25: Description Of Trikdis Config Status Bar

    Security control panel „FLEXi“ SP3 Setting parameters using TrikdisConfig software 1. Download the configuration software TrikdisConfig from www.trikdis.com/ (enter “TrikdisConfig” in the search field) and install it. 2. Connect the „FLEXi“ SP3 to a computer using a USB Mini-B cable.
  • Page 26: System Options " Window

    You can set the time by clicking the Set PC time button. If Disabled is chosen in the Time synchronization field, the computer’s time will be set for the control panel. If a modem or a server is chosen in the Time synchronization field, the control panel will synchronize its time according to that modem or server. www.trikdis.com July 2020...
  • Page 27 - recipients will receive event reports, but the siren will switch on only if the tamper event happens when the system is armed; „Always audible“ - recipients will receive event reports and the siren will will switch on even when the alarm system is disarmed. www.trikdis.com July 2020...
  • Page 28 Additional when holidays – perform an additional action during holidays. Only holidays – carry out the schedule during holidays.  Holiday group – specify a holiday group (Any/1/2/3/4) that the schedule will consider to be holidays. If “Any” is chosen, the schedule will operate in holiday mode during any active holiday. www.trikdis.com July 2020...
  • Page 29 6-symbol password only You know.  Installer Code – (default code - 654321) gives installers access to configuring the system. For safety purposes, change it into a 6-symbol code only You know. www.trikdis.com July 2020...
  • Page 30: Reporting To Cms" Window

     Port – enter the receiver’s network port number.  Protocol – TRK for data transfer using Trikdis receivers, SIA DC-09 for IP receivers capable of receiving event reports transmitted in SIA DC-09 protocols.  Phone number – (only for SMS messages) enter the phone number of a TRIKDIS SMS receiver. The telephone number must start with the international country code (e.g.
  • Page 31 LAN) is used. If there are no other connection methods, it is the main one. The T16 can only be used to send reports to the CMS.  Return to main (both channel) – time period after which the „FLEXi“ SP3 will attempt to regain connection using the primary channel, if it was running a backup channel, min www.trikdis.com July 2020...
  • Page 32: Users & Reporting " Window

    Areas – the areas that the specific user can control.  A – tick the box if you want to allow the user to ARM the alarm.  D – tick the box if you want to allow the user to DISARM the alarm. www.trikdis.com July 2020...
  • Page 33: Linking Rfid Key Fobs (Cards)

    5. To delete all keys (including the master key), hold the Master key against the reader for at least 20 seconds. Important: The purpose of the Master key is to link other electronic keys. If you use the Master key for ARM/DISARM commands, their execution will have a delay. www.trikdis.com July 2020...
  • Page 34 Protegus Cloud access code – 6-digit code for connecting with Protegus. “SMS answer texts” tab Settings group “SMS answer texts”  The text for answers to commands sent using SMS messages can be customized in the column SMS text. www.trikdis.com July 2020...
  • Page 35 Fast ARM – the buttons ARM, STAY, SLEEP can be used to quickly arm the security system without entering a code.  Incorrect codes until lockout – enter the number of incorrect codes allowed before blocking the keypad.  Lockout timer – enter the time for how long the keypad will be blocked. “RS485 modules” tab www.trikdis.com July 2020...
  • Page 36: Linking The Wireless Equipment Transceiver Rf-Sh To The „Flexi" Sp3 Control Panel

    5.6.2 Linking wireless (FW2 series) sensors 1. Make sure that the RF-SH transceiver is linked to the „FLEXi“ SP3 (see chapter 5.6.1 above). 2. Switch on the power supply. 3. Remove the top cover from the RF-SH transceiver. www.trikdis.com July 2020...
  • Page 37: Linking A Wireless (Fw2 Series) Remote Controller

    1. Press buttons 2 and 3 at the same time and hold until the indicator starts blinking in green and red. 2. You can release the buttons when the indicator stops blinking. The controller’s memory is cleared. www.trikdis.com July 2020...
  • Page 38 No. column must match the codes printed on the casings or boards of the sensors. 13. You must assign the sensors to zones and partitions of the security control panel (Zones window). Click Write [F5] after making the changes. www.trikdis.com July 2020...
  • Page 39 2. Launch TrikdisConfig, click the Read [F4] button. 3. In the TrikdisConfig window Wireless, in the column Device type, select Disabled instead of Keypad SH and click Write [F5]. The wireless keypad is now removed from the „FLEXi“ SP3’s memory. www.trikdis.com July 2020...
  • Page 40 Instant Stay – for connecting motion sensors. If an “Instant Stay” zone is violated when the alarm is armed, OUT outputs “Siren” and “Flash” are turned on and a message about the alarm being triggered is sent. When the alarm system is armed in STAY mode, “Instant Stay” zones are not protected. www.trikdis.com July 2020...
  • Page 41 Zn – zone number with the event identification word. Can be “Event” or “Restore”.  SMS text – description of the zone event that will be included in event reports sent to the user using SMS messages. www.trikdis.com July 2020...
  • Page 42 CMS – if this box is ticked, PGM output turn on/off reports will be sent to the central monitoring station (CMS).  Prot. – if the box is ticked, PGM output turn on/off reports will be sent to Protegus cloud. www.trikdis.com July 2020...
  • Page 43 %..– the ending of the received SMS message must match with the text entered after the % symbol. (e.g. %hoUSe. The SMS message must end with the text “hoUSe”. Example of an SMS message: 1144hoUSe). The SMS message text is case-sensitive. www.trikdis.com July 2020...
  • Page 44 Active – if the box is ticked, the thermostat will work with the selected temperature sensor according to the set temperature.  Sensor No – assign a temperature sensor to the thermostat.  Temperature – set the temperature that the thermostat will maintain. www.trikdis.com July 2020...
  • Page 45 If Dallas sensors are chosen, they will be linked automatically; Humidity & Temperature – one AM2301 temperature and humidity sensor can be connected. If the Humidity & Temperature sensor will be used, it must be manually assigned in the Module type column). www.trikdis.com July 2020...
  • Page 46 This tab will only be shown if there is at least one user in the “Users & Reporting” window.  ID – number and identification word (Event, Restore) of the event.  Event SMS text – text that will be used in event SMS messages. www.trikdis.com July 2020...
  • Page 47 2. Connect the „FLEXi“ SP3 to a computer using a USB Mini-B cable or connect to the „FLEXi“ SP3 remotely. If a newer version of firmware is available, the program will automatically offer to install it. 3. Open the TrikdisConfig window Firmware. www.trikdis.com July 2020...
  • Page 48 4. Click the Open firmware button and choose the required firmware file. If you do not have the file, the newest firmware file can be downloaded from the „FLEXi“ SP3 downloads section of www.trikdis.com by registered users. 5. Click the Update [F12] button.

Table of Contents