Installing The Pto Shield - Toro ProCore SR54 Operator's Manual

Hide thumbs Also See for ProCore SR54:
Table of Contents

Advertisement

Figure 18
Figure 19
14.
Using the dimensions determined in step 11,
locate, mark and cut off just the safety shields to
expose the tubes
Figure 20
Figure 21
15.
Carefully deburr the ends of the tubes with a file
and remove all the filings from the tubes.
16.
Grease the inside tube.
Note:
Telescoping tubes must always overlap
by 1/2 of their length in normal operation and at
least 1/3 of their length in all working conditions.
During transport, when the drive line is not
rotating, the telescoping tubes must have a
suitable overlap to maintain the tubes alignment
and allow them to slide freely.
(Figure 20
and
Figure
21).
9

Installing the PTO Shield

g237888
Parts needed for this procedure:
1
PTO shield
Procedure
1.
Remove the 4 bolts, lock washers, and flat
washers secured to the rear of the aerator
gearbox
(Figure
g237889
g237890
1. PTO shield
2. Flat washer
3. Lock washer
2.
Mount the PTO shield to the aerator gearbox
with the fasteners previously removed
22). When mounting the PTO shield, ensure
that the access panel
to the top or the side depending on the aerator
frame configuration.
g237891
14
22).
Figure 22
4. Bolt
5. Access panel
(Figure
(Figure
22) is positioned
g010849