Assembly Conditions For The Compact Device - Panasonic Aquarea B1 Planning And Installation Manual

Air-to-water heat pumps split systems and compact systems
Table of Contents

Advertisement

Planning
Example of an installation room with hydro-module and hot water tank PAW-TD20C1E5
Front view
2100
500
2
200
595
400
3
1
4
1 Domestic hot water tank
2
2 Hydro-module
400
3 Hot water outlet
200
1
~ 2,5 m²
!
IMPORTANT
Due to the available space of about 6.25 m³, the installation space in this example is only suit-
able for single- phase devices of the Aquarea LT series of up to 9 kW. The use of devices with
a larger quantity of coolant will exceed the practical limit c (for R410A, c = 0.44 kg/ m³ and for
R407C, c = 0.31 kg/ m³).
5.2.3 Setting up the Compact system
The compact system consists of a device, which has one or two fans, depending on the output
and model. So the devices differ according to the output
In the case of water pipelines of a compact device to a building, these are hot water pipelines
that are routed directly in contact with the outdoor air. As the water lines can freeze at outside
temperatures below 0 °C, they must be insulated according to the locally valid European, na-
tional and regional specifications and guidelines.
Example of Germany: The lines are to be insulated according to the current energy saving
ordinance (EnEV 2014) with double the minimum thickness according to annexure 5, table 1,
lines 1 to 4, but not less than 40 mm, relating to a thermal conductivity of 0.035.(m x K).
96
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
2
200
595
400
3
1
4
Plan view
2
400
200
1
~ 2,5 m²
5
400
4 Domestic cold water entry
400
5 Door to the installation room
5
(→ 1 Model range, p.
8).
400
CAUTION
Danger of water pipes freezing in outside temperatures below 0 °C
If the heating circuit in the compact system is filled with water and the outside temperature falls
below 0 °C, the risk exists in the compact system that the water pipes may freeze. This can
400
cause a lot of damage to the device.
The client should therefore ensure the absence of frost by taking one of the following
measures:
► Operate the heating circuit using a food-safe antifreeze mixture (propylene glycol).
► Provide an additional cabinet heating in the compact device, to prevent the heating
circuit from freezing up.
► Empty the heating circuit by using a built-in device (manually or automatically) before
freezing starts.
i
Note
Example of Germany: Details about preventing freezing of water-bearing pipelines and the heat
and cold protection are according to the VDI Guidelines VDI 2055 or VDI 2069.

5.2.3.1 Assembly conditions for the compact device

The assembly conditions for the compact device are as follows:
● The compact device has only been developed for outdoor installation and must not
● For condensation water drainage in defrosting mode, drainage is recommended
● It should be possible to smoothly divert the condensate from the device.
● Maintain the minimum distances
● The heat emission of the compact device must not be impeded by additional pro-
● No objects should be put up that can cause short-circuiting of the exhaust air. Even
● The operating sound of the compact device must not cause any stress to the user
● In addition, use vibration- damping rubber buffers for isolation.
● If installing the compact device near to the sea, in regions with a high content of
● In the case of installation locations experiencing strong winds e.g. on building roof-
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
be installed indoors.
via a drain pipe to the frost-free ground with gravel fill
device, p.
99).
(→ 5.2.3.2 Minimum distances for compact de-
vice, p.
98).
tection devices such as awnings or such.
when using multiple compact devices (e.g. in case of heat pump cascades), avoid air
flow short-circuiting on the side of air
(→ 5.2.3.3 Securing the compact device, p.
or to neighbours. Air-to-water heat pumps may in certain countries or regions re-
quire permission. All provisions regarding noise valid at the location must be taken
into account
(→ 5.2.1 Acoustics, p.
87).
sulphur or at sites where large quantities of oil (e.g. machine oil, etc.) are present,
its operating life may be shortened.
tops or between buildings, the compact device must be additionally secured to the
side of the building to prevent tipping over (e.g. by bracing).
Planning
(→ 5.2.3.3 Securing the compact
99).
97

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents