Panasonic Aquarea B1 Planning And Installation Manual page 25

Air-to-water heat pumps split systems and compact systems
Table of Contents

Advertisement

Product Description
Split systems with hydro-module / T-CAP model series / H Generation / Standard
T-CAP model series
Single-phase (230 V / 50 Hz), Heating and Cooling
Hydro-module
WH-SXC09H3E5
Outdoor unit
WH-UX09HE5
Set (hydro-module + outdoor unit)
KIT-WXC09H3E5
Model
B6
Heating capacity at +7 °C (A7/W35)
kW
9.00
COP at +7 °C (A7/W35)
4.84
Heating capacity at +2 °C (A2/W35)
kW
9.00
COP at +2 °C (A2/W35)
3.59
Heating capacity at -7 °C (A–7/W35)
kW
9.00
COP at -7 °C (A–7/W35)
2.85
Cooling capacity at 35 °C (A35/W7)
kW
7.00
EER (energy efficiency ratio) at 35 °C (A35/W7)
3.17
Energy efficiency class
at 35 / 55 °C
1
i / i
Hydro-module
Dimensions
H x L x W
mm
892 x 502 x 353
Weight
kg
44
Water-side connection
mm
28
Rotation speed stages
Variable
High efficiency pump
Power consumption (min./ max.) W
32 / 102
Water flow rate (A7/W35)
l/min
25.8
Power of E-heating element
kW
3
Power consumption
Heating / Cooling
kW
1.86 / 2.21
Operating and start up current Heating / Cooling
A
8.6 / 10.2
Max. power consumption on network connection 1 / 2
A
25.0 / 13.0
Recommended fuse for network connection 1 / 2
A
30 / 30
Recommended cable cross section for network connection 1 / 2 mm²
3 x 4.0 or 6.0 / 3 x 4.0
Outdoor unit
Sound pressure level
Heating / Cooling
dB(A)
51 / 49
Dimensions
H x L x W
mm
1,340 x 900 x 320
Weight
kg
101
Line diameter
Fluid line
mm (inches)
9.52 (3/8)
Gas line
mm (inches)
15.88 (5/8)
Pre-filled refrigerant (R410A) / CO
-equivalent
kg / t CO
-Equ. 2.85 / 5.951
2
2
Connection distance
m
3 – 30
Nominal connection distance
m
7
Pre-filled connection distance
m
10
Additional coolant fill-up quantity (R410A)
g/m
50
Max. height difference IU/OU
m
20
Operating range
Outside temperature (H / K)
°C
-20 to 35 / 16 to 43
Water outlet temperature (H / K) °C
25 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efficiency classes is based on the official ErP specifications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efficiency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efficiency class scale from A++ to G.
44
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Three-phase (400 V / 50 Hz), heating and cooling
WH-SXC12H6E5
WH-SXC09H3E8
WH-SXC12H9E8
WH-SXC16H9E8
WH-UX12HE5
WH-UX09HE8
WH-UX12HE8
WH-UX16HE8
KIT-WXC12H6E5
KIT-WXC09H3E8
KIT-WXC12H9E8
KIT-WXC16H9E8
B6
B6
B6
B6
12.00
9.00
12.00
16.00
4.74
4.84
4.74
4.28
12.00
9.00
12.00
16.00
3.44
3.59
3.44
3.10
12.00
9.00
12.00
16.00
2.72
2.85
2.72
2.49
10.00
7.00
10.00
12.20
2.81
3.17
2.81
2.57
i / i
i / i
i / i
i / i
892 x 502 x 353
892 x 502 x 353
892 x 502 x 353
892 x 502 x 353
45
45
46
52
28
28
28
28
Variable
Variable
Variable
Variable
34 / 110
32 / 102
34 / 110
30 / 105
34.4
25.8
34.4
45,9
6
3
9
9
2.53 / 3.56
1.86 / 2.21
2.53 / 3.56
3.74 / 4.76
11.7 / 16.5
2.8 / 3.4
3.9 / 5.4
5.7 / 7.2
29.0 / 26.0
14.7 / 13.0
11.9 / 13.0
15.5 / 13.0
30 / 30
16 / 16
16 / 16
16 / 16
3 x 4.0 or 6.0 / 3 x 4.0
5 x 1.5 / 3 x 1.5
5 x 1.5 / 5 x 1.5
5 x 1.5 / 5 x 1.5
52 / 50
51 / 49
52 / 50
55 / 54
1,340 x 900 x 320
1,340 x 900 x 320
1,340 x 900 x 320
1,340 x 900 x 320
101
109
109
119
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
2.85 / 5.951
2.85 / 5.951
2.85 / 5.951
2.90 / 6.243
3 – 30
3 – 30
3 – 30
3 – 30
7
7
7
7
10
10
10
10
50
50
50
50
20
20
20
20
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
-20 to 35
25 to 55 / 5 to 20
25 to 60 / 5 to 20
25 to 60 / 5 to 20
25 to 60 / 5 to 20
Split systems with hydro-module / T-CAP model series / H Generation / SQ version
T-CAP model series
Three-phase (400 V / 50 Hz), heating and cooling, noise-proofed version
Hydro-module
WH-SQC09H3E8
Outdoor unit
WH-UQ09HE8
Set (hydro-module + outdoor unit)
KIT-WQC09H3E8
Model
B7
Heating capacity at +7 °C (A7/W35)
kW
9.00
COP at +7 °C (A7/W35)
4.84
Heating capacity at +2 °C (A2/W35)
kW
9.00
COP at +2 °C (A2/W35)
3.59
Heating capacity at -7 °C (A–7/W35)
kW
9.00
COP at -7 °C (A–7/W35)
2.85
Cooling capacity at 35 °C (A35/W7)
kW
7.00
EER (energy efficiency ratio) at 35 °C (A35/W7)
3.17
Energy efficiency class
at 35 / 55 °C
1
i / i
Hydro-module
Sound pressure level
Heating / Cooling
dB(A)
33 / 33
Dimensions
H x L x W
mm
892 x 500 x 340
Weight
kg
43
Water-side connection
mm
28
Rotation speed stages
Variable
High efficiency pump
Power consumption (min./ max.) W
32 / 102
Water flow rate (A7/W35)
l/min
25.8
Power of E-heating element
kW
3
Power consumption
Heating / Cooling
kW
1.86 / 2.21
Operating and start up current Heating / Cooling
A
2.8 / 3.4
Max. power consumption on network connection 1 / 2
A
14.7 / 13.0
Recommended fuse for network connection 1 / 2
A
16 / 16
Recommended cable cross section for network connection 1 / 2 mm²
5 x 1.5 / 3 x 1.5
Outdoor unit
Sound pressure level
Heating / Cooling
dB(A)
47 / 48
Dimensions
H x L x W
mm
1,410 x 1,283 x 320
Weight
kg
151
Line diameter
Fluid line
mm (inches)
9.52 (3/8)
Gas line
mm (inches)
15.88 (5/8)
Pre-filled refrigerant (R410A) / CO
-equivalent
kg / t CO
-Equ.
2.85 / 5.951
2
2
Connection distance
m
3 – 30
Nominal connection distance
m
5
Pre-filled connection distance
m
10
Additional coolant fill-up quantity (R410A)
g/m
50
Max. height difference IU/OU
m
20
Operating range
Outside temperature (H / K)
°C
-20 to 35 / 16 to 43
Water outlet temperature (H / K) °C
20 to 60 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efficiency classes is based on the official ErP specifications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been in
force since 26. September 2015. Other ErP relevant information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efficiency class scale from A++ to G.
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
WH-SQC12H9E8
WH-SQC16H9E8
WH-UQ12HE8
WH-UQ16HE8
KIT-WQC12H9E8
KIT-WQC16H9E8
B7
B7
12.00
16.00
4.14
4.28
11.40
13.00
3.44
3.28
10.00
11.40
2.73
2.68
10.00
12.20
2.81
2.56
i / i
i / i
33 / 33
33 / 33
892 x 500 x 340
892 x 500 x 340
44
45
28
28
Variable
Variable
34 / 110
30 / 105
34.4
45,9
9
9
2.53 / 3.56
3.74 / 4.76
3.9 / 5.4
5.7 / 7.2
11.9 / 13.0
15.5 / 13.0
16 / 16
16 / 16
5 x 1.5 / 5 x 1.5
5 x 1.5 / 5 x 1.5
48 / 49
51 / 53
1,410 x 1,283 x 320
1,410 x 1,283 x 320
151
161
9.52 (3/8)
9.52 (3/8)
15.88 (5/8)
15.88 (5/8)
2.85 / 5.951
2.99 / 6.243
3 – 30
3 – 30
5
5
10
10
50
50
20
20
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
25 to 60 / 5 to 20
25 to 60 / 5 to 20
45