GE IC3645SR7A353T4 Installation And Operation Manual page 24

Separately excited (sx) transistorized motor controllers for neighborhood electric vehicle applications
Table of Contents

Advertisement

INSTALLATION AND OPERATION
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Armature transistor did not turn on
-45
properly.
MEMORY RECALL
YES
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Traction
Defective control.
Controller
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
"Look Ahead" test for A2 volts is less
-46
than 12.5% of battery volts.
MEMORY RECALL
YES
SYMPTOM
Line contactor will not pickup.
Circuits valid
for
POSSIBLE CAUSE
Traction
Check for short circuit from the motor
Controller
armature to the frame of the vehicle.
Defective control.
CORRECTIVE ACTIONS
Replace controller unit.
CORRECTIVE ACTIONS
Replace controller unit.
CAUSE OF STATUS INDICATION
This status code will be displayed when, during
control operation, the armature transistor fails to turn
on properly. This will result in a PMT condition
TROUBLE-SHOOTING DIAGRAM
NO GRAPHIC FOR THIS
STATUS CODE
CAUSE OF STATUS INDICATION
This status code will be displayed when the voltage at
A2 is less than 12.5% of battery volts and I
than 52 amps, when the control is in the neutral state,
with no start switch selected.
TROUBLE-SHOOTING DIAGRAM
FU3 *
10A
LINE *
FU1 *
400A
+
POS
POWER CONNECTIONS
-
NEG
Page 24
is greater
m
A1
F1
A1
A1
F1
TO CONTROL
F2
A2
A2
F2
A2
Updated Sept 2019