Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 200

Motion module instructions, standard functions/ function blocks
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Operation result
The operation result will be as follows.
Operation result
No operation error
Operation error
• Timing chart
When n=T#5s (5s)
ON
(s)
OFF
ON
(d1)
OFF
0
0
1
(d2)
(1)
(1) When (s) turns on, (d1) turns on. When (s) turns on, (d2) starts measuring time.
(2) When the time measured in (d2) reaches the time set in (n), (d1) turns off.
(3) When both (s) and (d1) are off, the value in (d2) is initialized.
Operation error
Error code
Description
3401H
The output time setting value exceeds the valid range.
19 TIMER FUNCTION BLOCKS
198
19.1 Pulse Timer
ON
OFF
2
3
4
5
(2)
(d1), (d2)
Operation result output value
Undefined value
ON
OFF
ON
0
0
1
(3)
2
3
4

Hide quick links: