Note: The Groundsmaster 360 Series Multi-Purpose
Machine must be equipped with the Light Kit, Model
30512 or 30516 to operate the Registration Plate Kit
Light.
1. Position the machine on a level surface, stop the
engine, remove the ignition key and engage the
parking brake.
1. Registration plate bracket
2. Screws, #10 x 5/8 inch
3. Plate light
4. Flange head screw, 5/16 x .613 inch
5. Lock nut, #10
2. Centering the registration plate bracket on the rear
of the hood, use it as a template to locate, mark
and drill (2) 9 mm diameter holes through the hood
(Figure 1).
© 2011—The Toro® Company
8111 Lyndale Avenue South
Bloomington, MN 55420
Registration Plate Kit
Groundsmaster
®
Model No. 120-6678
360 Series Multi-Purpose Machine
CAUTION
If you leave the key in the ignition switch,
someone could accidently start the engine and
seriously injure you or other bystanders.
Remove the key from the ignition switch before
you do any maintenance.
Figure 1
6. Flange head nut, 5/16 inch
7. Tree bracket
8. Plastic tree plug (shown removed for clarity)
9. Wire harness
10. Drill a 13 mm diameter hole here
3. At the approximate location shown in Figure 1, mark
and drill a 13 mm diameter hole through the interior
wall of the hood, near the seal bracket.
4. Route the bullet connector end of the wire harness
through the drilled hole.
Register at www.Toro.com.
Form No. 3369-161 Rev A
Installation Instructions
Original Instructions (EN)
Printed in the USA.
All Rights Reserved

Advertisement

loading

Summary of Contents for Toro Groundsmaster 360 Series

  • Page 1 ® 360 Series Multi-Purpose Machine Model No. 120-6678 Installation Instructions Note: The Groundsmaster 360 Series Multi-Purpose CAUTION Machine must be equipped with the Light Kit, Model If you leave the key in the ignition switch, 30512 or 30516 to operate the Registration Plate Kit someone could accidently start the engine and Light.
  • Page 2 5. Install a tree bracket onto each of the harness clips (Figure 1). 6. Route the wire harness along the top left side of the hood while plugging the tree brackets onto the hoods existing plastic tree plugs (Figure 1). 7.

This manual is also suitable for:

Groundsmaster 360 120-6678