Tapping amount with end temperature
Tapping amount 55°C*
PAW-VP500LDHW
[°C]
>65°C
>60°C
>55°C
>50°C
>45°C
>40°C
* Based on:
End temperature: 55°C, 50°C, 45°C
Outdoor temperature: +7°C
City water temperature: 15°C
Without reheating
Heating the water from 15°C to end temperature
Please note: The data mentioned in this document is gotten by calculation (approximation).
PAW-VP•LDHW - Technical Manual – 2019-11
Tapping amount 50°C*
PAW-VP500LDHW
[ltr.]
[°C]
115.05
>65°C
18.84
>60°C
75.52
>55°C
110.51
>50°C
42.05
>45°C
29.10
>40°C
Please use only for reference.
Performance Characteristic Tables
Tapping amount 45°C*
PAW-VP500LDHW
[ltr.]
[°C]
0.00
>65°C
110.67
>60°C
23.21
>55°C
118.24
>50°C
60.05
>45°C
48.95
>40°C
[ltr.]
0.00
0.00
0.00
127.83
16.32
137.25
3