Huawei RTN 360 V100 Quick Installation Manual page 5

Hide thumbs Also See for RTN 360 V100:
Table of Contents

Advertisement

Terminating a Ground Cable with an OT Terminal
Strip the ground cable.
A: OT terminal
B: ground cable
C: exposed cable conductor
L1: length of the exposed cable
When you are skillful, you can determine L1
based on the length of the OT terminal lug.
When striping off the insulation layer of the
ground cable, take care not to damage or nick
the metal conductor of the cable.
Preparing an RSSI Test Cable
Terminate one end of an outdoor network cable with an RJ45 connector by
following instructions in "Terminating an Outdoor Network Cable with
Shielded RJ45 Connectors."
Strip the other end of the cable, remain the core wire for pin 4 (blue) and that for
pin 7 (white and brown), cut off the other core wires, and wrap this end.
Mapping Between the RTN 360 and the PIs
PI-DC B10
Device Type
PI Support
Power Supply
(Yes/No)
Mode
RTN 360
Yes
Force mode only
08/09 >>
Mapping between the cross-sectional area of a
cable conductor (C) and the length of an exposed
cable (L1)
Cross-sectional
Area of C (mm
)
2
1
1.5
2.5
4
6
10
16
25
35
50
White and brown
core wire
Blue core wire
PI-DC A10
PI-DC A11
PI Support
Power Supply
PI Support
Power Supply Mode
(Yes/No)
Mode
(Yes/No)
Turn the DIP switch to
Yes
Force mode only
Yes
the PSE-PD mode.
Fit the exposed cable into the OT terminal.
L1 (mm)
7
7
7
8
9
11
13
14
Ensure that the cable conductor does not
16
protrude more than 2 mm from the OT terminal.
16
PI-AC/DC B20
PI Support
Power Supply Mode
(Yes/No)
Turn the DIP switch to
Yes
the PSE-PD mode.
Crimp the OT terminal lug.
Crimp the OT
terminal lug.
The crimping impression may differ depending on
the crimping tool used.

Advertisement

Table of Contents
loading

Table of Contents