TILT TOP OVERBED TABLE
MODEL NO. 6418
NOTE: Check ALL parts for shipping damage. In case of
shipping damage, DO NOT use. Contact Carrier/Dealer
for further instruction.
SAFETY SUMMARY
The following recommendations are made for the safe
assembly of the Tilt Top Overbed Table:
WARNING
DO NOT assemble or use this equipment without
first reading and understanding this instruction
sheet. If you are unable to understand the Warn-
ings, Cautions or Instructions, contact a health-
care professional, dealer or technical personnel
before attempting to install this equipment - oth-
erwise, injury or damage may occur.
After assembly and BEFORE use, ensure ALL at-
taching hardware is securely tightened.
Do NOT remove shipping screw and shipping
strap from column assembly prior to assembly.
The column assembly is spring loaded and may
cause injury.
ASSEMBLING THE TILT TOP
OVERBED TABLE (FIGURE 1)
NOTE: Before assembly, refer to WARNINGS in the
SAFETY SUMMARY of this instruction sheet.
1. Lay the tilt top table assembly on a flat surface as
shown in
2. Position column assembly onto top bracket.
3. Align holes in the column assembly with holes in the
top bracket.
4. Secure column assembly to top bracket and tilt top
table assembly with shoulder bolt and locknut. Se-
curely tighten.
5. Place the base assembly upside down on a flat sur-
face with the top bracket facing UP.
6. Install one (1) caster, by pushing the stem portion
into the base frame, until it snaps into place.
7. Repeat
for remaining three (3) casters.
8. Position bolt plate onto base frame.
9. Secure the bolt plate and base frame to the column
assembly using the two (2) bolts. Hand tighten.
Assembly, Installation and Operating Instructions
.
10. Position the table on its side.
NOTE: This will prevent excess stress on the bolts when
securing.
11. Securely tighten the two (2) bolts in
12. Remove the shipping screw and shipping strap from
the column assembly.
13. Adjust or tilt the overbed table, if necessary. Refer to
in this instruction sheet.
Bolts
Column
Assembly
Screw and
Shoulder Bolt
Locknut
FIGURE 1 - ASSEMBLING THE TILT TOP
OVERBED TABLE
ADJUSTING/TILTING THE TILT
TOP OVERBED TABLE (FIGURE 2)
NOTE: The table MUST be in the upright position BE-
FORE adjusting/tilting.
Adjusting
1. Press DOWN on the lower portion of the release
lever and adjust the Tilt Top Overbed Table UP
or DOWN.
2. Release the lever when at the desired position.
.
Bolt Plate
Caster
Shipping
Base Frame
Strap
Top Bracket
Tilt Top Table
Assembly

Advertisement

loading
Need help?

Need help?

Do you have a question about the 6418 and is the answer not in the manual?

Questions and answers

Summary of Contents for Invacare 6418

  • Page 1 TILT TOP OVERBED TABLE MODEL NO. 6418 Assembly, Installation and Operating Instructions 10. Position the table on its side. NOTE: Check ALL parts for shipping damage. In case of shipping damage, DO NOT use. Contact Carrier/Dealer NOTE: This will prevent excess stress on the bolts when for further instruction.
  • Page 2 This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state. Invacare warrants its product to be free from defects in materials and workmanship for three (3) years for the original purchaser. If within such warranty period any such product shall be proven to be defec- tive, such product shall be repaired or replaced, at Invacare's option.