Define Parameters Of Tcp/Ip Communication With A Control - Siemens SINUMERIK 840Di sl Commissioning Manual

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

Result
The Automation License Manager displays the data in the navigation and object area
according to the status of the SINUMERIK plug-in.
The folder symbols and names are displayed in the navigation area depending on the status
of the SINUMERIK plug-in and the communication link to the SINUMERIK control:
● SINUMERIK plug-in disabled:
● SINUMERIK plug-in enabled, but no communication link with SINUMERIK control:
● SINUMERIK plug-in enabled, communication link established with SINUMERIK control:
17.3.4

Define parameters of TCP/IP communication with a control

Background
To be able to read or transfer license information to or from the MCI board of a control
system, the Automation License Manager must communicate with the control system via
TCP/IP.
Requirements:
● HMI basic software is installed
● SINUMERIK-specific plug-ins are enabled
General communication parameters
The default general communication parameters for the HMI basic software are stored in the
following initialization file:
<installation drive>:\Siemens\Sinumerik\HMI-Advanced\mmc2\MMC.INI
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
PlugIn SINUMERIK - - - - disabled - - - -
SINUMERIK - online - - - - no connection available - - - -
SINUMERIK - offline - - - - no data available - - - -
SINUMERIK <control type> - <hardware serial number>
Note
If the view is not automatically refreshed, you can refresh the view manually. Refer to
Subsection "Update the "Manage" Navigation view" (Page 580).
Note
If the SINUMERIK user interface "HMI Advanced" is installed on the same computer
(PC/PG) as the Automation License Manager you can set the IP address using the user
interface.
The IP address for the control system with which both HMI Advanced as well as the
Automation License Manager communicate is set via the following dialog:
Operating area switchover > Startup > HMI > NCU link
This requires at least the password of protection level 2 (manufacturer) to be set.
17.3 Assigning via Automation License Manager
License management
577