Siemens SINAMICS SL150 6SL39616RC100AA02 Operating Instructions & Installation Instructions

Medium-voltage
Table of Contents

Advertisement

Quick Links

Edition
10/2019
Operating Instructions
Installation Instructions
Medium-Voltage Drive
SINAMICS SL150
Type 6SL39616RC100AA02
This documentation pertains to
EXAMPLE
www.siemens.com/drives

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SINAMICS SL150 6SL39616RC100AA02

  • Page 1 This documentation pertains to EXAMPLE Operating Instructions Installation Instructions Medium-Voltage Drive SINAMICS SL150 Type 6SL39616RC100AA02 Edition 10/2019 www.siemens.com/drives...
  • Page 2 28.10.2019 14:58 V18.00...
  • Page 3 Introduction Safety information Description Medium-Voltage Drive Preparations for use SINAMICS SL150 Type 6SL39616RC100AA02 Mounting Electrical connection Operating Instructions Installation Instructions Commissioning Operation Maintenance Spare parts Disposal This documentation pertains to Service & Support EXAMPLE Technical specifications and drawings Edition 10/2019...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    SITOP Select .........................28 3.1.2.11 Sirius safety relay........................28 3.1.2.12 Customer terminal strips ......................29 Options...........................29 3.2.1 Water cooling expansion (option A08) ...................29 3.2.2 3 adapters for PSA and SINAMICS SITOR interface on control compartments (option A24)............................29 SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 6 4.5.4 Opening doors in preparation for use..................51 4.5.5 Checking the shock and tilt indicators inside the cabinet............51 Storage...........................52 4.6.1 Storing a device ........................52 Mounting..............................55 Safety instructions for installation...................55 Tools required ........................56 Torques ..........................56 SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 7 9.4.1 Replacing a fan ........................79 9.4.2 Replacing the battery in the fan/battery module of the SIMOTION Control Units ....80 Cleaning ..........................81 9.5.1 Cleaning aluminum parts .......................82 Repairs...........................82 9.6.1 Replacing the CompactFlash card ..................84 SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 8 Spare parts ..............................85 Disposal..............................87 11.1 Disposing of packaging material ....................87 11.2 Removing device components and old devices ..............87 Service & Support............................89 Siemens Industry Online Support ..................89 SIOS App ..........................90 Technical specifications and drawings .......................91 Index................................93 Tables Table 3-1 DRIVE-CLiQ interface .........................26 Table 5-1 Tightening torque for screws .......................56...
  • Page 9 Table of contents Figure 9-1 Change the battery in the fan/battery module ................80 SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 10 Table of contents SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 11: Introduction

    ● Lists are formatted as bulleted lists. – Lists on the second level are hyphenated. Note The note provides you with additional information about the product itself, handling the product - and the relevant documentation. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 12 Introduction 1.2 Text format features SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 13: Safety Information

    EN 50110‑1 "Working in a voltage-free state". Apply the five safety rules in the sequence stated before starting work. 5 safety rules 1. Disconnect the system. Also disconnect the auxiliary circuits, for example, anti-condensation heating. 2. Secure against reconnection. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 14: Safe Handling

    Danger due to high auxiliary voltages High auxiliary voltages are still present even after shutdown. Touching live parts can result in death or serious injury. ● Observe the five safety rules when performing any work. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 15 ● Ensure that the anti-condensation heating cannot be touched. ● Ensure that the anti-condensation heating is switched off before carrying out any repair or maintenance work. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 16: Electromagnetic Fields In Electrical Power Engineering Installations

    ● Therefore, do not carry magnetic or electronic data storage media with you. Nominated persons in control of electrical installations can find further information on electromagnetic fields under "Information for persons responsible for plants and systems." SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 17: Components That Can Be Destroyed By Electrostatic Discharge (Esd)

    The necessary ESD protective measures for the entire working range for electrostatically sensitive devices are illustrated once again in the following drawings. Precise instructions for ESD protective measures are specified in the standard DIN EN 61340‑5‑1. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 18: Information For Nominated Persons In Control Of An Electrical Installation

    ● Never operate the device in an explosive atmosphere (hazardous zone). Non-observance of proper usage Improper use of the devices described can result in death, severe injury or material damage. ● Please observe all instructions for proper use. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 19 Make use of the support and services offered by the relevant service center for planning, installation, commissioning, and servicing work. You can find the relevant contact person under "Service & Support (Page 89)". SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 20: Grounding Concept

    The converter will be supplied on request without an electromechanical door interlocking system if space is restricted. In this instance, the customer must provide an access interlock system compliant with IEC 61800-5 /-1. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 21: Instructions For Inverters With No Grounding Switch

    According to the EU machinery directive, machine manufacturers / plant operators must conduct a risk assessment of their machine. Plant operators must conduct a risk assessment of their plant. In particular, pay attention to Annex 1 "General Principles" of the EU machinery directive. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 22 – Operating and/or environmental conditions outside of the specification – Condensation/conductive contamination – External influences/damage ● The release of substances and emissions that are harmful to the environment Improper operation or the improper disposal of components can harm the environment. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 23: Security Information

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 24 "SINAMICS Industrial Security" Manual Notes relating to Industrial Security are provided here (https:// support.industry.siemens.com/cs/ww/de/view/109751848/en). "Security Guidelines for SIMATIC HMI devices" Manual Notes relating to Industrial Security for HMI devices are available here. (https:// support.industry.siemens.com/cs/de/en/view/109481300) SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 25: Description

    The operator panel has the following functions: ● Touch-screen operation ● Screen saver ● Language switching ● Local operation ● TRACE function ● Display of converter faults and alarms ● Fault memory, can be read out via USB SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 26: Description Of The Components

    DRIVE-CLiQ interface Signal name Technical data Transmit data + Transmit data - Receive data + Reserved, do not use Reserved, do not use Receive data - Reserved, do not use Reserved, do not use SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 27: Cbe20 And Cbe30 Communication Modules

    ● You will find information on the wiring in the circuit manual in the "Technical data and drawings" appendix. ● Information is provided on the interfaces and LEDs in the "Supplementary component descriptions" document on the CD. See also Technical specifications and drawings (Page 91) SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 28: Smc30 Sensor Module

    Sirius safety relay The safety relay monitors the status of the Emergency Off circuit, and is used to implement a safety-related shutdown when dangerous conditions occur. LEDs indicate the operating state and the function. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 29: Customer Terminal Strips

    3 adapters for PSA and SINAMICS SITOR interface on control compartments (option A24) The adapters adapt the SINAMICS closed-loop control to existing power units employing SITOR technology. The option is used with the 6-pulse circuit of a three-phase cycloconverter. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 30: Adapters For Psa And Sinamics Sitor Interface In Closed-Loop Control Cabinet (Option A25)

    One power stack adapter (PSA) and one SINAMICS SITOR interface are installed and wired on each of the six control compartments. One adapter is used in each case for the thyristors in one phase. The control panels are installed in an additional cabinet. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 31: Figure 3-2 Additional Cabinet

    Description 3.2 Options ① Adapter for PSA and SINAMICS SITOR interface (6 x) ② Terminal blocks (4 x) Figure 3-2 Additional cabinet SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 32: Figure 3-3 Interconnection

    Schematic representation of the connection for PSA - SSI adapter to the power unit ① Actual values ② Valve checkback signals ③ Firing control from the PSA ④ Actual value acquisition ⑤ Firing outputs Figure 3-3 Interconnection SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 33: Figure 3-4 Installation And Interconnection Of The Sitor Adapter

    SSI on a control panel installed together with the PSA and interconnected to the fiber-optic cables. ① Power Stack Adapter (PSA) ② Control panel ③ Fiber-optic cables ④ SINAMICS SITOR Interface (SSI) Figure 3-4 Installation and interconnection of the SITOR adapter SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 34: Tm31 Terminal Module (Option C01)

    In addition to the three SMC30 Sensor Modules, a DMC20 DRIVE-CLiQ hub and an interface converter are included. The SMC30 Sensor Module cannot loop through DRIVE-CLiQ wiring. This is the reason that the DRIVE-CLiQ hub is required. The DRIVE-CLiQ hub collects the signals from the three SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 35: Padu8 Diagnosis Module (Option G66)

    SIMOTION D445. The option comprises the following components: ● 26 digital electronic modules with 4 inputs (6ES7131-4BD01-0AA0 / 4DI 24V DC) ● 2 digital electronic modules with 4 inputs (6ES7132-4BD32-0AA0 / 4DO 24V DC) SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 36: Electronic Power Supply With 18 V Dc Infeed (Option K72)

    A differential pressure technique continually determines the amount of dust in the filter mats. When the differential pressure switch responds, a fault message is output and the converter is switched off. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 37: Ip54 Degree Of Protection (Option M54)

    3.2 Options 3.2.18 IP54 degree of protection (option M54) The degree of protection of the closed-loop control is increased to IP54. An additional fan provides for sufficient cooling. Figure 3-6 Fan with option M54 SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 38 Description 3.2 Options SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 39: Preparations For Use

    ● Under no circumstances may the circuit breaker be electrically or mechanically externally closed. A mechanical interlock of the manual ON command at the circuit breaker prevents destruction of the converter as a result of an uncoordinated switch-on operation. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 40 Ensure that the circuit breaker has additional intrinsic device protection. The intrinsic device protection must be switched off within 100 ms of a short-circuit current at the latest. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 41: Requirements When Mounting And Installing The Device

    The operating areas must be dry and free of dust. The air supplied must not contain any electrically conductive gas, vapors, or dust which could impair operation. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 42: Requirements Placed On The Levelness Of The Floor

    (responded) This can result in death, serious injury or material damage. ● If one of the indicators has tripped, do not perform any commissioning. ● Inform the Technical Support. Only specialist Siemens technicians can recommend appropriate measures. See also Service & Support (Page 89) SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 43: Checking The Load Handling Attachments

    If the load suspension devices and lifting gear are damaged or not correctly secured, the equipment may be dropped during lifting and transportation. This can result in death, serious injury or material damage. Inspect the load handling attachments and lifting gear before use. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 44: Transportation

    ● When lifting, refer to the information on the lifting plate or in "Technical data and drawings." NOTICE Vibrations Significant vibration during transportation and shocks when setting down can damage the equipment. Avoid vibrations and shocks. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 45: Observe Center Of Gravity

    ● Transport the transport unit/cabinet with the greatest care. ● Choose the lowest transport height possible. The pallet may not touch the ground. Always transport the cabinet in an upright position. ● Avoid driving over bumps. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 46: Transport With A Crane

    This can result in death, serious injury or material damage. ● Use suitable lifting rods for transporting. The weight of the cabinet is indicated on the rating plate. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 47: Figure 4-4 Lifting Bar Label

    5. Lift the cabinet. Avoid shifting the center of gravity or distorting or damaging the cabinet. When suspended, the cabinet must be parallel to the ground. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 48: Transporting Transportation Units Packed In Boxes

    To protect the boxes against pressure, use sufficiently long rope and a spreader beam. Please proceed as follows: 1. Attach the rope/cable to the pallet as shown in the following diagram. ① 2. Attach the rope/cable to the spreader beam and the crane hook. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 49: Unpacking

    Carefully observe the instructions for storage in Chapters "Storage" and "Technical data and drawings". Remove the packaging immediately prior to installation. The units are packed by the manufacturers in accordance with the order. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 50: Removing Load Securing Devices

    Lifting the cabinet off the transport pallet Use a crane to lower the transportation units from the transport pallets and transport them to the installation site. Observe the guidelines described in the section "Transport with a crane." SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 51: Opening Doors In Preparation For Use

    If transport indicators remain in the device during operation, material damage can result when they fall off – or as a result of temperature damage. ● Remove the transport indicators before commissioning. Remove any adhesive residue from the transport indicators using methylated spirits. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 52: Storage

    – Room temperature should be approx. 10 °C (14 °F) above the outside temperature. – The temperature may not fall below ‑20 °C (-4 °F). – For lower temperatures, agree on suitable measures together with Siemens. – Relative humidity should be less than 60%.
  • Page 53 – Place a humidity meter that can be read from outside inside the film wrapping. Observe the values provided in the technical specifications on relative humidity. Check the values regularly using the humidity meter. – Inspect the device regularly. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 54 Preparations for use 4.6 Storage SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 55: Mounting

    If foreign bodies are left in the device after installation and maintenance work, this can cause damage when the device is switched on. ● Before switching on, check as to whether there are any foreign bodies in the device. Remove any foreign bodies. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 56: Tools Required

    Examples of soft materials are Cu, Al, CuZn cable entries, laminate materials, plastics, cast resin post insulators, press nuts, welding nuts, blind rivet nuts, and cage nuts. Hard materials S2 are materials with friction-enhancing washer components, e.g. a contact washer. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 57: Connect To The Foundation

    Install the transport units in accordance with the specifications provided in the accompanying dimension drawings. When doing this, maintain the specified distance between the top of the cabinet and the ceiling. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 58 Mounting 5.4 Connect to the foundation SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 59: Electrical Connection

    When operated with an insufficient degree of protection, this can result in death, serious injury and material damage. ● To maintain the degree of protection, after installation, immediately seal the holes so they are air-tight. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 60 If you are connecting the mains and motor-side power cables, when shrinking the cable terminations, other control lines and fiber-optic cables in the surrounding cable channels can become damaged. ● When shrinking, ensure not to damage cables in the surrounding cable channels. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 61: Note On Shielded Cables

    ● Connect painted or anodized metal components using contact washers or remove the insulating layer. ● Use unpainted, de-oiled mounting plates. ● Establish a central connection between ground and the protective conductor system (PE protective conductor). SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 62 ● Apply the cable shield so that it covers the greatest possible surface area. Use ground clamps, ground terminals or ground screw connections. ● Avoid extending the cable shield to the grounding point using a wire. This reduces the shield effectiveness by up to 90%. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 63: Figure 6-1 Shield Connection Using A Clip

    ● Ensure that the cable shield is correctly connected. ● Bridge shield gaps (at terminals, circuit-breakers, contactors, etc.) with minimum impedance and through the largest possible surface area. ① Shield busbars ② Cables ③ Terminals Figure 6-2 Bridging shield gaps SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 64: Connecting Equipotential-Bonding Conductors

    Connect all internal and external components to this equipotential bonding busbar. is Attach the shields of incoming and outgoing cables directly to the shield bus. It is important here to establish the greatest possible area of contact and a good conductive connection. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 65: Connecting The Protective Grounding

    In this way you avoid ground loops and line-frequency interference. You can also connect the open shield end to the enclosure via a radio interference suppression capacitor (e.g. 0.1 µF 100 V MKT). SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 66: Separating Adjacent Cabinets Using Unsuppressed Contactors

    Each cabinet has a grounding lug for grounding the components installed in the cabinet. It is located at the bottom of the cabinet. Connect the cabinets securely to the plant grounding system via these grounding lugs. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 67: Connecting Circuit Breakers

    3. Connect the shields of the control cables to the serrated bar. For additional information, see Chapter "Using the equipotential bonding strip and shield bus (Page 64)". 4. Connect the control cables as specified in the circuit manual. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 68: Connecting The External Safety Loop

    3. Connect the external safety circuit to these terminals. 6.11 Interconnecting optional connections Depending on the range of options installed, further connections have to be interconnected. Detailed information about interconnecting these options with the interfaces is provided in the circuit manual. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 69: Fastening The Cable Ducts With Cable Ties

    Fasten all cable ducts whose cover faces downward with cable ties. Wind the cable ties around the entire cable duct. The cable ties must be located at the same positions as in the delivered state. Figure 6-7 Schematic diagram: Fastening the cable ties SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 70 Electrical connection 6.12 Fastening the cable ducts with cable ties SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 71: Commissioning

    Obtain information about the range of SITRAIN training courses available through your local contact person. Make use of the support and services offered by the responsible Siemens Service Center when commissioning this equipment. You can find the relevant contact person under "Service &...
  • Page 72 Commissioning SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 73: Operation

    ● Observe the maximum permitted short-circuit currents and maximum specified short-circuit times. Damage caused by incorrect parameter assignment Malfunctions can occur if you change parameters. ● Do not change the parameters, e.g. for the motor circuit-breaker. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 74: Fault And System Messages

    LED for Sirius safety relay Operation Device Line Sensor Start pushbutton Safety-related output Green Green Not confirmed Was confirmed Closed Green Was confirmed Open Green Not confirmed Open Fault Cross-circuit or no power supply Open SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 75: Maintenance

    This can result in death, severe injuries and significant material damage. ● You must always handle the capacitors as if they are charged. ● Discharge the snubber circuit capacitors. ● Short-circuit the snubber circuit capacitors before commencing any work. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 76 "Visual inspections". ● Dust deposits inside the cabinet unit must be removed at regular intervals (or at least once a year) by qualified personnel in line with the relevant safety regulations. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 77: Opening The Device

    See also Visual inspections (Page 78) Note Siemens offers its customers support in the form of a service contract. For further details, contact your regional office or sales office. Note Inform the manufacturer about each maintenance job that has been carried out and about each spare part replacement for the purposes of a reliability analysis.
  • Page 78: Visual Inspections

    "Visual inspections". ● Dust deposits inside the cabinet unit must be removed at regular intervals (or at least once a year) by qualified personnel in line with the relevant safety regulations. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 79: Checking The Isolating Clearances

    If the converter is equipped with a temperature-controlled fan, the fan can run on even if the power section is switched off. You can be injured if you touch the fan. ● Wait until the fan has shut down. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 80: Replacing The Battery In The Fan/Battery Module Of The Simotion Control Units

    7. Press in the battery. 8. Hold the fan/battery module at an angle to the front with the open side facing up (battery visible). SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 81: Cleaning

    For significant levels of pollution and dirt, use an ESD cloth soaked in ethyl alcohol (however, not so much that it drips from the cloth). SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 82: Cleaning Aluminum Parts

    Inadequate diagnostic and error rectification measures can result in material damage. ● We recommend using an uninterruptible power supply (UPS). If you are unsure of the measures necessary after the device fails, or if a fault cannot be rectified, contact the Service Center. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 83 Measures in the event of an error It is not possible to fully test repairs that are carried out on site. Return the defective module back to the manufacturing plant for repair. The relevant address is available from your Siemens contact person.
  • Page 84: Replacing The Compactflash Card

    ● Only remove or insert the CompactFlash card when the power is switched off. 2. Withdraw the CompactFlash card from the Control Unit. Back up the data saved on it. 3. Copy the stored data of the previous CompactFlash card to the new original Siemens card. Note Invalid software key The software key is associated with the serial number of the CompactFlash card.
  • Page 85: Spare Parts

    ● Therefore, only use spare parts that have been approved by the manufacturer. To request spare parts, please contact the Siemens sales office responsible for your region. You can find an overview of the Siemens contact partners in your region here (www.siemens.com/services/partner).
  • Page 86 Spare parts SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 87: Disposal

    ● Shut down the device before disassembling. Ground the device ● With old devices, also follow the instructions in the section "Transport." For the following components, pay special attention when disposing or reusing: ● Batteries ● Capacitors SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 88 Disposal 11.2 Removing device components and old devices ● PCBs ● Electronic components SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 89: Service & Support

    Service & Support Siemens Industry Online Support Technical questions or additional information If you have any technical questions or require additional information, please contact Technical Support (https:// support.industry.siemens.com/cs/ww/en/sc/2090). Please have the following data ready: ● Type ● Serial number You can find this data on the rating plate.
  • Page 90: Sios App

    A.2 SIOS App SIOS App Siemens Support for on the move With the "Siemens Industry Online Support" App, you can access more than 300,000 documents for Siemens Industry products – any time and anywhere. The App supports you in the following areas: ●...
  • Page 91: Technical Specifications And Drawings

    Technical specifications and drawings Note Finding technical data and drawings The technical data and the necessary drawings can be found in "Technical data and drawings" manual. SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 92 Technical specifications and drawings SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 93: Index

    Index " "Siemens Industry Online Support" App, 90 Grounding ESD shoe grounding strips, 17 Grounding concept, 20 Grounding point, 62 Insufficient grounding, 66 5 safety rules, 13 Protective ground conductor, 20 Shield busbar, 20 Shield connection, 62 Actual value sensing, 35...
  • Page 94 Index Voltage Sensing Module VSM, 27 SINAMICS SL150 6SL39616RC100AA02 Operating Instructions Rev.201910281458 EXAMPLE...
  • Page 96 0009993961 000010 01 EN 01 Further Information www.siemens.com/LDA Siemens AG Large Drives Applications Vogelweiherstr. 1-15 90441 NÜRNBERG GERMANY *000999396100001001EN01* 000999396100001001EN01...
  • Page 97 Large Drives Applications Department DI MC CBMF MF-NMA LDA EN Siemens AG, DI MC CBMF MF-NMA LDA EN, Postfach 47 43, 90025 Nürnberg Tel. +49 (911) 433-6422 +49 (911) 433-6921 PD LD AP BA OM Email motoren.doku.aud@internal.siemens.co Yasmin Marx Gugelstr. 65 Our ref.
  • Page 99 Spine label for binder 50 mm (120 g/m2) SINAMICS SL150 6SL39616RC100AA02 EXAMPLE Operating Instructions Spine label for binder 145 mm (120 g/m2) SINAMICS SL150 6SL39616RC100AA02 EXAMPLE Operating Instructions / Installation Instructions...

Table of Contents