Smc40 Sensor Module Cabinet (Only For Direct Measuring Systems) - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

5.2.3.4

SMC40 Sensor Module Cabinet (only for direct measuring systems)

Table 5- 23
Meaning of the LEDs on the Sensor Module Cabinet-Mounted SMC40
LED
Color
RDY
READY
Green
Orange
Red
Green/red Flashing
Green/
orange
or
Red/
orange
The parameters for activating component recognition can be taken from the following reference:
1)
Reference: SINAMICS S120/S150 List Manual
Each channel has a multifunction LED.
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Status
Description, cause
Off
The electronics power supply is missing or outside the
permissible tolerance range.
Continuous
The component is ready for operation. Cyclic DRIVE-CLiQ
light
communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
This component has at least one fault.
light
Note:
LED is controlled irrespective of the corresponding mes-
sages being reconfigured.
Firmware download is complete. The system waits for
light
POWER ON.
2 Hz
Flashing
Component recognition via LED is activated
light
Note:
Both options depend on the LED status when component
recognition is activated.
5.2 Diagnostics using LEDs
Remedy
Correct and
acknowledge the fault.
Carry out a POWER
ON.
.
1)
Diagnostics
323

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SINAMICS S120 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF